Parker Hannifin C3S063V2F10I20T30M00 is a NANKMOS industrial automation product record Listed under Other series series and Drives. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.
Brand names are used for identification only.
Parker Hannifin C3S063V2F10I20T30M00 is a NANKMOS industrial automation product record Listed under Other series series and Drives. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.
| Manufacturer | Parker Hannifin |
|---|---|
| Application | Industrial Network Communication |
| Part Number / Model | C3S063V2F10I20T30M00 |
| Compatible System | Confirmed by inquiry |
| Condition Options | To Confirm |
| Module Type | Communication Module |
| Warranty | 12 Months |
| Packaging | Anti-static Bag / Secure Box |
| Shipping Methods | DHL / FedEx / UPS / Air / Sea |
| Availability | To Confirm |
| Lead Time | To Confirm |
| Documentation | Part number and revision checked before quote |
The Parker C3S063V2F10I20T30M00 is a high-performance Compax3 series servo drive engineered for seamless integration into industrial data networks. Rated at 6.3A continuous output current and designed for 230VAC single-phase or three-phase supply, this unit delivers precision motion control while simultaneously serving as a live node on PROFIBUS DP and CANopen communication backbones. In modern smart factory architectures, where every actuator, sensor, and controller must contribute to a unified data fabric, the C3S063V2F10I20T30M00 bridges the gap between field-level motion execution and plant-wide supervisory intelligence.
From the moment a motion command originates in a Siemens S7-1500 PLC or an Allen-Bradley ControlLogix controller, the C3S063V2F10I20T30M00 receives, decodes, and executes it with sub-millisecond response latency. Its dual-protocol gateway capability — supporting both PROFIBUS DP at up to 12 Mbit/s and CANopen at configurable baud rates — means it can coexist in heterogeneous network topologies without requiring additional protocol converters or intermediate gateways. This native multi-protocol support is the foundation of its value in connected factory deployments.
In a fully connected smart factory, the C3S063V2F10I20T30M00 occupies a critical position in the data chain — sitting between field-level mechanical execution and the digital intelligence layer above it. Consider a typical production line: a Balluff inductive proximity sensor detects a workpiece position and feeds a digital signal to a remote I/O module such as a Phoenix Contact Axioline F station. That station aggregates field signals and forwards structured process data upstream via PROFIBUS DP, where the C3S063V2F10I20T30M00 acts as a slave node, receiving velocity and torque setpoints from the PLC in real time.
The PLC — for example a Siemens S7-300 or S7-400 running Step 7 or TIA Portal — orchestrates the motion sequence and simultaneously pushes status data to a WinCC SCADA system via Industrial Ethernet. The C3S063V2F10I20T30M00 mirrors its own drive status — actual position, following error, fault codes, thermal load — back to the PLC over PROFIBUS DP, ensuring the SCADA historian captures every motion event with timestamp accuracy. This bidirectional data flow is what transforms a simple servo axis into a transparent, auditable production asset.
On the CANopen side, the C3S063V2F10I20T30M00 can simultaneously participate in a distributed motion network alongside Parker ACR9000 multi-axis controllers or Compax3M multi-axis variants, synchronizing position profiles across multiple servo axes without burdening the PROFIBUS segment. A Beckhoff CX series embedded PC running TwinCAT can serve as the CANopen master, coordinating electronic gearing and cam profiles across the C3S063V2F10I20T30M00 and adjacent axes in a flying shear or winding application.
At the edge layer, an industrial PC or edge gateway — such as a Moxa UC-8100 or a Advantech WISE-5000 series data acquisition module — can poll the SCADA OPC-UA server to extract drive KPIs and push them to cloud analytics platforms. This enables remote engineers to monitor spindle load trends, detect bearing wear signatures in torque ripple data, and schedule predictive maintenance interventions without dispatching field technicians. The C3S063V2F10I20T30M00's network transparency is what makes this remote diagnostic loop possible.
For HMI visualization, a Weintek MT8000 or Siemens TP1200 Comfort Panel connects to the PROFIBUS segment or to the PLC's Ethernet port, rendering real-time drive status — speed, torque, fault state, encoder position — on operator dashboards. Alarm events generated by the C3S063V2F10I20T30M00 propagate through the PLC alarm buffer to the HMI and simultaneously to the SCADA alarm management system, ensuring no fault goes unacknowledged regardless of shift staffing levels.
Power infrastructure for the drive is typically supplied through a Parker AC10 or AC30 series line filter and DC bus capacitor bank, ensuring clean power delivery and compliance with EMC directives. An industrial UPS or a Phoenix Contact QUINT power supply upstream of the drive cabinet provides ride-through capability during brief grid disturbances, protecting in-progress motion sequences from interruption.
Many automation sites operate with a fragmented communication landscape: legacy PROFIBUS segments coexist with newer CANopen motion networks, and neither speaks directly to the Ethernet-based SCADA layer without middleware. The C3S063V2F10I20T30M00 addresses this by natively supporting both fieldbus protocols within a single drive unit, eliminating the need for standalone protocol gateways that introduce additional failure points and latency.
Data silos are a persistent challenge in multi-vendor production environments. When a servo drive cannot report its own health data to the plant historian, maintenance teams rely on manual inspection cycles that miss early-stage fault signatures. The C3S063V2F10I20T30M00's PROFIBUS DP interface exposes a rich set of process data objects — including actual current, DC bus voltage, drive temperature, and fault history — that SCADA systems can log continuously, enabling trend analysis and anomaly detection algorithms to flag degradation before it becomes a production stoppage.
Remote monitoring is increasingly mandatory in facilities with distributed production cells or geographically separated plants. By integrating the C3S063V2F10I20T30M00 into a PROFIBUS network that terminates at an OPC-UA gateway, remote engineers gain read/write access to drive parameters — acceleration ramps, current limits, homing sequences — without requiring physical access to the control cabinet. This capability reduces mean time to repair (MTTR) significantly in facilities where specialist servo engineers are not on-site 24/7.
Production line transparency — knowing exactly which axis is running, at what load, and with what remaining service life — is achievable when every drive node contributes structured data to the plant network. The C3S063V2F10I20T30M00 supports this transparency model, and its pre-shipment functional test and 12-month warranty provide the reliability baseline that industrial procurement teams require when specifying network-connected motion components.
Q1: What is the communication latency of the C3S063V2F10I20T30M00 on a PROFIBUS DP network? PROFIBUS DP cycle times depend on the number of slaves and the configured baud rate. At 12 Mbit/s with a typical segment of 8–16 slaves, bus cycle times of 1–3 ms are achievable. The C3S063V2F10I20T30M00 responds within one bus cycle, making it suitable for closed-loop position control applications where deterministic response is required.
Q2: Can the C3S063V2F10I20T30M00 operate on PROFIBUS DP and CANopen simultaneously? Yes. The Compax3 platform supports concurrent operation on both fieldbus interfaces. PROFIBUS DP can handle supervisory setpoints and status reporting while CANopen manages synchronized multi-axis motion profiles, allowing the drive to participate in two independent network topologies without conflict.
Q3: How does the unit support remote diagnostics and fault tracing? The C3S063V2F10I20T30M00 exposes fault codes, warning states, thermal load percentage, and encoder feedback data as PROFIBUS DP process data objects (PDOs). These values are readable by any SCADA or OPC-UA gateway connected to the PROFIBUS master, enabling remote engineers to diagnose faults, review fault history, and adjust drive parameters without on-site access.
Q4: What warranty and pre-shipment testing does this unit include? Every C3S063V2F10I20T30M00 unit supplied by NANKMOS undergoes pre-shipment functional testing covering power-on verification, fieldbus communication handshake, and output stage integrity checks. A 12-month warranty is included from the date of shipment, covering manufacturing defects and component failures under normal operating conditions.
Functional Inspection100% tested on professional platforms to ensure stable performance.
Anti-static PackagingModules are packed in anti-static bags to prevent electrostatic damage.
Secure Export PackingCushion protection and strong cartons ensure safe transportation.
Worldwide ShippingGlobal logistics network supports air, sea and express delivery.
Documentation CheckPart number, revision and compatibility verified before shipment.
After-sales SupportProfessional technical support to help resolve your issues.