Siemens 6FX1124-6AA02 Drive Network Interface Board

Siemens 6FX1124-6AA02 is a NANKMOS industrial automation product record Listed under SIMODRIVE series and Drives. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.

Brand names are used for identification only.
Product Snapshot

Availability & Sourcing Details

Siemens 6FX1124-6AA02 is a NANKMOS industrial automation product record Listed under SIMODRIVE series and Drives. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.

Network Module Drive System SIMODRIVE Siemens
Application
Industrial Network Communication
Condition Options
New / Used / Refurbished
Availability
Confirmed by Email
Warranty
12 Months
Packaging
Anti-static Bag / Secure Box
Shipping
DHL / FedEx / UPS / Air / Sea

Product Information

ManufacturerSiemens
ApplicationIndustrial Network Communication
Part Number / Model6FX1124-6AA02
Compatible SystemSIMODRIVE
SeriesSIMODRIVE
Condition OptionsTo Confirm
Module TypeCommunication Module
Warranty12 Months
PackagingAnti-static Bag / Secure Box
Shipping MethodsDHL / FedEx / UPS / Air / Sea
AvailabilityTo Confirm
Lead TimeTo Confirm
DocumentationPart number and revision checked before quote
Product Details

6FX1124-6AA02 Product Description

The Siemens 6FX1124-6AA02 is a PROFIBUS-DP network interface board engineered for SIMODRIVE servo and spindle drive systems. Designed to bridge field-level drive hardware with upper-level control and monitoring architectures, this module enables real-time data exchange between CNC controllers, PLC platforms, and distributed automation networks. In smart factory environments where production continuity depends on uninterrupted data flow, the 6FX1124-6AA02 delivers the protocol-level connectivity that keeps drive systems visible, controllable, and diagnostically accessible from any point in the automation hierarchy.

At its core, the 6FX1124-6AA02 functions as a PROFIBUS-DP slave interface, allowing SIMODRIVE drive units to participate directly in fieldbus-based control loops. This eliminates the need for proprietary point-to-point wiring between the drive and the controller, replacing it with a standardized, high-speed digital communication channel. The result is faster setpoint transmission, more accurate feedback capture, and a dramatically reduced wiring footprint — all critical advantages in high-density machine tool and motion control installations.

In a typical smart factory data chain, the 6FX1124-6AA02 sits between the SIMODRIVE power module and the PROFIBUS-DP master — commonly a Siemens SINUMERIK 840D CNC controller or a SIMATIC S7-300/S7-400 PLC. The CNC or PLC issues motion commands and parameter requests over the PROFIBUS segment; the 6FX1124-6AA02 decodes these frames and translates them into drive-native control signals, while simultaneously feeding back encoder position data, speed references, fault codes, and status words to the master. This bidirectional data loop forms the foundation of closed-loop motion control in CNC machining centers, grinding machines, and multi-axis transfer lines.

Understanding how the 6FX1124-6AA02 fits into a complete smart factory data chain requires tracing the signal path from the physical process layer up through the control and supervisory layers. At the field level, servo motors and spindle drives equipped with incremental or absolute encoders generate position and velocity feedback signals. These signals enter the SIMODRIVE drive module, where the 6FX1124-6AA02 board captures and digitizes them, packaging the data into PROFIBUS-DP process data objects (PDOs) for transmission upstream.

The PROFIBUS-DP segment connects the 6FX1124-6AA02 to the SINUMERIK 840D CNC controller — the motion master that orchestrates multi-axis interpolation, feed rate control, and spindle synchronization. In parallel, a SIMATIC S7-300 or S7-400 PLC may supervise auxiliary machine functions such as coolant control, tool changer sequencing, and safety interlocks, all sharing the same PROFIBUS backbone. The 6FX1124-6AA02 enables both the CNC and the PLC to read drive status words, write setpoints, and trigger parameter changes without interrupting the real-time motion loop.

Above the PLC layer, a SIMATIC ET 200S or ET 200M remote I/O station may aggregate digital and analog signals from proximity sensors, pressure transducers, and temperature transmitters distributed across the machine. These I/O nodes communicate with the S7 controller over the same PROFIBUS segment, creating a unified data bus that carries both drive feedback and process sensor data. A CP 342-5 or CP 443-5 PROFIBUS communication processor in the S7 rack bridges this fieldbus data to the plant Ethernet backbone, making it accessible to SCADA and MES systems.

At the supervisory layer, Siemens WinCC SCADA software or a third-party OPC-UA gateway aggregates drive performance data — including torque utilization, speed deviation, fault history, and energy consumption — from the PROFIBUS network. Operators at SIMATIC HMI TP1200 or OP panels can monitor real-time drive status, acknowledge alarms, and initiate parameter adjustments without entering the machine enclosure. This remote visibility is particularly valuable in multi-machine production cells where a single operator must oversee several SIMODRIVE-equipped machining centers simultaneously.

For edge analytics and predictive maintenance, an industrial edge gateway such as a SIMATIC IPC or a third-party Linux-based edge device can subscribe to drive data streams via OPC-UA or MQTT, applying local analytics to detect bearing wear signatures, thermal drift, or abnormal current profiles before they escalate into unplanned downtime. The 6FX1124-6AA02's role in this architecture is foundational: without reliable PROFIBUS-DP connectivity at the drive level, none of the upstream data aggregation, visualization, or predictive analytics functions are possible.

Power supply stability for the PROFIBUS segment and the drive control electronics is maintained by a SITOP PSU100S or equivalent 24 VDC industrial power supply, ensuring that communication integrity is preserved even during load transients or partial power events. The complete data chain — from encoder feedback through the 6FX1124-6AA02, across the PROFIBUS segment, through the S7 PLC and CP communication module, up to WinCC SCADA and the edge gateway — represents a fully integrated smart factory connectivity architecture built on proven Siemens automation standards.

Many industrial sites operating legacy SIMODRIVE systems face a common set of connectivity challenges: drive units that cannot report their status to the control system in real time, protocol mismatches between older drive hardware and modern Ethernet-based SCADA platforms, and the absence of structured fault data that would allow maintenance teams to diagnose problems remotely. The 6FX1124-6AA02 directly addresses the first and most fundamental of these gaps by giving SIMODRIVE drives a standardized PROFIBUS-DP interface that integrates cleanly with both legacy S7 controllers and modern SINUMERIK CNC platforms.

For sites transitioning from hardwired analog drive control to digital fieldbus architectures, the 6FX1124-6AA02 eliminates the data isolation that characterizes analog-only drive installations. Once the drive is on the PROFIBUS segment, its operational data — speed, torque, position error, fault codes, and parameter values — becomes available to any PROFIBUS master on the network, including SCADA gateways and data historians. This transforms a previously opaque drive unit into a fully transparent node in the plant data infrastructure.

Alarm management also improves significantly when drives are connected via PROFIBUS-DP. Instead of relying on discrete fault relay outputs that provide only binary fault/no-fault information, the 6FX1124-6AA02 enables the transmission of structured fault codes and diagnostic data to the PLC and SCADA system. Maintenance teams can receive specific fault descriptions — overcurrent, encoder error, communication timeout — directly on their HMI screens or mobile devices, reducing mean time to repair and eliminating the need for on-site fault code lookup procedures.

System expansion is equally simplified. Adding a new SIMODRIVE axis to an existing machine requires only assigning a PROFIBUS node address to the new 6FX1124-6AA02 board and configuring the corresponding GSD file in the STEP 7 or TIA Portal project. No additional wiring infrastructure is required beyond the existing PROFIBUS cable, and the new drive immediately becomes visible to the CNC controller and SCADA system. This plug-and-participate architecture supports the incremental capacity expansion strategies common in automotive, aerospace, and precision machining environments.

Q1: What is the maximum PROFIBUS-DP transmission speed supported by the 6FX1124-6AA02, and does network cable length affect communication reliability? The 6FX1124-6AA02 supports standard PROFIBUS-DP baud rates up to 12 Mbit/s. Maximum segment length depends on the selected baud rate: at 12 Mbit/s, the maximum cable length per segment is 100 m; at 1.5 Mbit/s, it extends to 200 m. For longer installations, PROFIBUS repeaters can extend the network. All units supplied by NANKMOS are pre-tested at the target baud rate to confirm stable communication before shipment.

Q2: Is the 6FX1124-6AA02 compatible with both SINUMERIK 840D and SIMATIC S7 PLC masters on the same PROFIBUS segment? Yes. The 6FX1124-6AA02 operates as a PROFIBUS-DP slave and is compatible with any DP master that supports the standard GSD-based configuration process, including SINUMERIK 840D CNC controllers and SIMATIC S7-300/S7-400 PLCs with CP 342-5 or integrated DP interfaces. Multi-master configurations are also supported within PROFIBUS-DP protocol constraints, allowing both a CNC and a PLC to access drive data on the same segment.

Q3: How does the 6FX1124-6AA02 support remote diagnostics and predictive maintenance in a smart factory environment? Once integrated into the PROFIBUS-DP network, the 6FX1124-6AA02 enables continuous transmission of drive diagnostic data — including fault codes, warning states, speed deviation, and torque utilization — to the PLC and SCADA system. This data can be forwarded via OPC-UA or MQTT to edge analytics platforms for trend analysis and predictive maintenance algorithms. NANKMOS performs a full communication and functional test on every 6FX1124-6AA02 prior to shipment, and each unit is covered by a 12-Month Warranty to support long-term deployment confidence.

Q4: What is the warranty coverage and what does the pre-shipment testing process include? Every 6FX1124-6AA02 supplied by NANKMOS carries a 12-Month Warranty covering manufacturing defects and functional failures under normal operating conditions. Pre-shipment testing includes PROFIBUS-DP communication verification, encoder interface signal integrity checks, and power-on functional validation. Units that do not pass all test criteria are not shipped. In-stock units are available for immediate dispatch with global shipping support.

Quality & Delivery Assurance

Functional InspectionFunctional Inspection

100% tested on professional platforms to ensure stable performance.

Anti-static PackagingAnti-static Packaging

Modules are packed in anti-static bags to prevent electrostatic damage.

Secure Export PackingSecure Export Packing

Cushion protection and strong cartons ensure safe transportation.

Worldwide ShippingWorldwide Shipping

Global logistics network supports air, sea and express delivery.

Documentation CheckDocumentation Check

Part number, revision and compatibility verified before shipment.

After-sales SupportAfter-sales Support

Professional technical support to help resolve your issues.

Related Models Often Requested

View More Related Models