Global Industrial Automation Sourcing

EN  /  CN
NANKMOSEmpower Industry. Advance Future.
Send Inquiry

FANUC A05B-2518-C200 Teach Pendant

FANUC A05B-2518-C200 is a NANKMOS industrial automation product record Listed under Other series series and Business & Industrial > Automation, Control & Flow Devices > Programmable Logic Controllers. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.

Brand names are used for identification only.
Product Snapshot

Availability & Sourcing Details

FANUC A05B-2518-C200 is a NANKMOS industrial automation product record Listed under Other series series and Business & Industrial > Automation, Control & Flow Devices > Programmable Logic Controllers. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.

Controller Module PLC System FANUC
Application
Controller Processing & System Control
Condition Options
New / Used / Refurbished
Availability
Confirmed by Email
Warranty
12 Months
Packaging
Anti-static Bag / Secure Box
Shipping
DHL / FedEx / UPS / Air / Sea

Product Information

ManufacturerFANUC
ApplicationController Processing & System Control
Part Number / ModelA05B-2518-C200
Compatible SystemConfirmed by inquiry
Condition OptionsTo Confirm
Module TypeController / CPU Module
Warranty12 Months
PackagingAnti-static Bag / Secure Box
Shipping MethodsDHL / FedEx / UPS / Air / Sea
AvailabilityTo Confirm
Lead TimeTo Confirm
DocumentationPart number and revision checked before quote
Product Details

A05B-2518-C200 Product Description

The FANUC A05B-2518-C200 iPendant is a high-performance, network-linked teach pendant engineered for seamless integration within the FANUC R-30iB and R-30iA robot controller ecosystem. Designed for demanding smart factory environments, this iPendant serves as the primary human-machine interface node in a layered industrial data architecture — bridging real-time robot motion data, process feedback, and diagnostic signals across the full automation chain.

In modern connected manufacturing, the A05B-2518-C200 operates at the intersection of field-level device communication and supervisory control. Robot joint positions, torque feedback, alarm states, and I/O status are continuously streamed through the R-30iB controller's internal EtherNet/IP and PROFINET-compatible communication backbone, making this iPendant a live data terminal for operators and SCADA engineers alike. Whether integrated into a Siemens S7-1500 PLC-coordinated cell or a Rockwell Automation ControlLogix-based production line, the A05B-2518-C200 delivers consistent, low-latency command and feedback loops essential for precision automation.

The A05B-2518-C200 iPendant anchors the human-machine interface layer in a multi-tier smart factory data flow. At the field level, robot end-effectors and peripheral sensors — including FANUC-compatible vision sensors and force/torque sensors — feed real-time process data into the R-30iB controller. The iPendant aggregates this data and presents it to operators while simultaneously relaying structured status packets upstream via the FANUC FOCAS2 Ethernet library.

Within the control network, the R-30iB controller communicates with upstream PLCs such as the Siemens S7-300 or Mitsubishi MELSEC iQ-R series via EtherNet/IP or PROFINET, enabling coordinated multi-axis motion sequencing and interlocked safety logic. The iPendant's alarm and fault data is captured by the controller and forwarded to SCADA platforms — including Wonderware InTouch or Ignition SCADA — through OPC-UA gateways or direct Ethernet connections, enabling plant-wide visibility of robot cell health.

For remote I/O expansion, the R-30iB controller supports connection to FANUC A03B-series remote I/O units, extending digital and analog signal reach across the robot cell without additional wiring complexity. These I/O nodes communicate over the FANUC I/O Link protocol, with status data accessible through the iPendant interface for rapid field diagnostics.

Edge gateway devices — such as those running on industrial Linux platforms with MQTT or OPC-UA stacks — can subscribe to FOCAS2 data streams from the R-30iB controller, enabling cloud-level data aggregation and AI-driven predictive maintenance. The A05B-2518-C200 iPendant's role in this architecture is critical: it provides the local operator interface while the controller's network stack handles upstream data routing to MES and ERP systems.

In variable-speed drive applications, the robot cell may include FANUC Alpha series servo amplifiers or third-party inverters such as the Yaskawa GA700 coordinated via DeviceNet or EtherNet/IP. The iPendant provides direct visibility into drive fault codes and motion profiles, reducing mean time to repair (MTTR) during production incidents. Industrial managed switches — such as those from the Hirschmann MICE series or Moxa EDS-400 series — provide the Layer 2 network infrastructure that ensures deterministic packet delivery between the robot controller, PLC, and SCADA nodes.

Many automation sites face persistent challenges: protocol fragmentation between legacy PLCs and modern robot controllers, data silos that prevent plant-wide OEE visibility, and limited remote diagnostic capability for robot cells located in hazardous or hard-to-access areas. The FANUC A05B-2518-C200 iPendant, when deployed within a properly architected R-30iB system, directly addresses these pain points.

Protocol Unification: The R-30iB controller's multi-protocol support — accessible and configurable via the A05B-2518-C200 iPendant — allows a single robot cell to communicate simultaneously with EtherNet/IP-based Rockwell PLCs and PROFINET-based Siemens systems, eliminating the need for standalone protocol converters in many configurations.

Data Silo Elimination: By enabling FOCAS2 Ethernet data extraction, the iPendant-equipped R-30iB controller becomes a transparent data source for MES and SCADA platforms. Production counts, cycle times, alarm histories, and axis load data are all accessible programmatically, enabling real-time dashboards and KPI tracking without manual data entry.

Remote Monitoring and Diagnostics: FANUC's iRVision and FANUC FIELD system integrations allow remote access to robot cell status via secure Ethernet connections. Operators can review alarm logs, check I/O states, and initiate controlled restarts without physical access to the cell — reducing downtime and improving safety compliance.

Production Line Transparency: Alarm tracking and fault history stored in the R-30iB controller are surfaced through the A05B-2518-C200 iPendant interface, enabling maintenance teams to identify recurring fault patterns, schedule predictive maintenance, and reduce unplanned stoppages.

System Scalability: The iPendant's compatibility across the R-30iB, R-30iA, and R-30iB Plus controller families ensures that as production lines expand — adding robot cells, remote I/O nodes, or new communication protocols — the existing iPendant infrastructure remains valid, protecting capital investment.

Q1: What communication protocols does the FANUC A05B-2518-C200 iPendant support for SCADA integration?The A05B-2518-C200 operates with the FANUC R-30iB controller, which natively supports EtherNet/IP and PROFINET. SCADA integration is typically achieved via the FANUC FOCAS2 library over TCP/IP (port 8193), enabling real-time data extraction of robot status, alarm codes, position data, and I/O states into platforms such as Ignition, Wonderware, or custom OPC-UA servers. DeviceNet connectivity is available via optional gateway modules.

Q2: Is the A05B-2518-C200 compatible with both R-30iA and R-30iB controllers, and will it work on a mixed-generation production line?Yes. The A05B-2518-C200 iPendant is designed for use with FANUC R-30iB and R-30iA controller families. In mixed-generation environments, compatibility should be verified against the specific controller software version (system software CNC series). NANKMOS provides pre-shipment functional testing on all iPendant units to confirm interface compatibility before dispatch.

Q3: How does the iPendant support remote diagnostics and what is the network latency impact?Remote diagnostic access to the R-30iB controller is facilitated via FOCAS2 Ethernet or FANUC's optional iRVision/FIELD system integration. Network latency for FOCAS2 data polling is typically under 10ms on a properly segmented industrial LAN (100 Mbps managed switch infrastructure). For time-critical motion commands, the iPendant's direct serial connection to the controller ensures deterministic response independent of network load.

Q4: What warranty and quality assurance does NANKMOS provide for the A05B-2518-C200?All FANUC A05B-2518-C200 iPendant units supplied by NANKMOS carry a 12-month warranty from the date of shipment. Each unit undergoes pre-shipment functional testing including display verification, button response check, and controller communication handshake validation. Verified stock is maintained for rapid dispatch. For volume orders or urgent replacement requirements, contact our team directly for lead time confirmation and RFQ support.

Quality & Delivery Assurance

Functional InspectionFunctional Inspection

100% tested on professional platforms to ensure stable performance.

Anti-static PackagingAnti-static Packaging

Modules are packed in anti-static bags to prevent electrostatic damage.

Secure Export PackingSecure Export Packing

Cushion protection and strong cartons ensure safe transportation.

Worldwide ShippingWorldwide Shipping

Global logistics network supports air, sea and express delivery.

Documentation CheckDocumentation Check

Part number, revision and compatibility verified before shipment.

After-sales SupportAfter-sales Support

Professional technical support to help resolve your issues.

Related Models Often Requested

View More Related Models