Global Industrial Automation Sourcing

EN  /  CN
NANKMOSEmpower Industry. Advance Future.
Send Inquiry

OMRON F3SJ-A0245P14-L Safety Light Curtain

Omron F3SJ-A0245P14-L is a NANKMOS industrial automation product record Listed under Other series series and Business & Industrial > Automation, Control & Flow Devices. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.

Brand names are used for identification only.
Product Snapshot

Availability & Sourcing Details

Omron F3SJ-A0245P14-L is a NANKMOS industrial automation product record Listed under Other series series and Business & Industrial > Automation, Control & Flow Devices. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.

Automation Part Control System Omron
Application
Industrial Automation Maintenance
Condition Options
New / Used / Refurbished
Availability
Confirmed by Email
Warranty
12 Months
Packaging
Anti-static Bag / Secure Box
Shipping
DHL / FedEx / UPS / Air / Sea

Product Information

ManufacturerOmron
ApplicationIndustrial Automation Maintenance
Part Number / ModelF3SJ-A0245P14-L
Compatible SystemConfirmed by inquiry
Condition OptionsTo Confirm
Module TypeAutomation, Control & Flow Devices
Warranty12 Months
PackagingAnti-static Bag / Secure Box
Shipping MethodsDHL / FedEx / UPS / Air / Sea
AvailabilityTo Confirm
Lead TimeTo Confirm
DocumentationPart number and revision checked before quote
Product Details

F3SJ-A0245P14-L Product Description

The Omron F3SJ-A0245P14-L is a Type 4 safety light curtain engineered for high-precision machine guarding in smart factory environments. With a 245 mm protective zone, 14 mm optical resolution, and native EtherNet/IP connectivity, this device does far more than stop a machine — it becomes an active node in your plant's industrial data network. Safety status, diagnostic codes, beam interruption events, and muting states are all transmitted in real time across the automation backbone, enabling SCADA systems, PLCs, and HMI panels to act on live safety data rather than simple relay contacts.

Designed to IEC 61496-1/-2 Type 4 standards and rated SIL 2 / PLe / Category 4 per IEC 62061 and ISO 13849-1, the F3SJ-A0245P14-L integrates directly into Omron's NX/NJ Series safety CPU platforms via the NX-SL5500 safety network controller, eliminating the need for dedicated safety relay modules and reducing panel wiring complexity. The result is a leaner, more transparent safety architecture that supports both machine-level interlocking and plant-wide safety data aggregation.

In a modern smart factory, the F3SJ-A0245P14-L functions as a safety-aware data source embedded directly in the machine network. Consider a typical press or robotic welding cell: the light curtain's OSSD outputs connect to the Omron NX-SL5500 safety network controller, which in turn communicates over EtherNet/IP to the NX102 machine automation controller. The safety CPU evaluates the curtain's CIP Safety data — beam status, diagnostic flags, and muting confirmation — and passes structured safety events upstream to the Omron NA5 HMI panel for operator visualization.

Simultaneously, the NX102 controller forwards aggregated machine state data, including safety zone status, to the plant SCADA layer via OPC UA or Modbus TCP, depending on the site's network architecture. Facilities running Omron Sysmac Studio can configure the F3SJ-A0245P14-L's EtherNet/IP assembly objects directly within the same engineering environment used for motion control and I/O mapping, eliminating the need for separate safety configuration tools.

For multi-zone installations — such as a transfer line with three robot cells — multiple F3SJ-A0245P14-L units can be daisy-chained using the F3SJ's cascading function, with each zone's status individually addressable over the network. The NX-SL5500 aggregates all zone states into a single safety data block, which the SCADA system can poll at 100 ms intervals for real-time production floor visibility. When a beam interruption occurs, the event timestamp, zone ID, and beam position are logged automatically, enabling maintenance teams to perform root-cause analysis without physical inspection.

Remote diagnostic capability is further enhanced when the F3SJ-A0245P14-L is paired with an Omron NX-EIC202 EtherNet/IP coupler and remote I/O modules. Maintenance engineers can query curtain health — including emitter/receiver alignment margin, contamination level, and OSSD test pulse status — from any SCADA workstation on the plant network, or via a VPN-connected laptop running Omron's CX-One or Sysmac Studio. This eliminates the need for on-site visits during shift changes and supports predictive maintenance scheduling based on alignment trend data.

On the power and infrastructure side, the F3SJ-A0245P14-L operates on 24 VDC supplied by an Omron S8VK-series DIN-rail power supply, which itself can be monitored for output voltage and current via a connected power monitoring module. The entire safety and data chain — from the light curtain's optical beam through the safety CPU, EtherNet/IP switch, SCADA server, and historian — forms a closed-loop diagnostic network that supports both real-time alarming and long-term OEE analysis.

Protocol fragmentation is one of the most persistent challenges in brownfield automation sites. Older machine guarding systems rely on hardwired relay contacts that provide no diagnostic data beyond a simple on/off signal. The F3SJ-A0245P14-L's EtherNet/IP interface replaces this opaque relay output with a structured data stream that SCADA and MES systems can consume directly, eliminating the protocol translation layer that typically introduces latency and data loss.

Data silos between safety systems and production systems are broken down when the F3SJ-A0245P14-L's CIP Safety data is mapped into the same EtherNet/IP network used by motion controllers, vision systems, and barcode readers. A single Omron NX102 controller can host both the safety logic and the standard automation program, with safety data accessible to the standard task for logging and reporting — without compromising the safety integrity of the OSSD circuit.

Remote monitoring becomes practical when the curtain's diagnostic data is surfaced through the plant's existing SCADA infrastructure. Alarm thresholds for alignment margin degradation can be configured in the SCADA historian, triggering maintenance work orders automatically when the curtain's optical margin drops below a defined percentage — before a nuisance trip occurs on the production line.

Production line transparency is achieved by mapping each F3SJ-A0245P14-L zone to a specific machine or cell in the SCADA graphic display. Operators can see at a glance which safety zones are active, which are in muting mode, and which have logged recent interruption events — enabling faster response to safety incidents and more accurate shift handover reporting.

System expansion is straightforward: additional F3SJ-A Series curtains, Omron F3W-MA Series area sensors, or Omron G9SP safety controllers can be added to the EtherNet/IP network without rewiring the safety relay panel, as each device is addressed individually on the network and configured through the same Sysmac Studio project file.

Q1: Does the F3SJ-A0245P14-L support real-time diagnostic data over EtherNet/IP, or only safety OSSD signals? The F3SJ-A0245P14-L transmits both CIP Safety OSSD data and diagnostic assembly objects over EtherNet/IP simultaneously. Diagnostic data includes beam interruption position, alignment margin percentage, contamination level, muting state, and OSSD test pulse status — all accessible to the connected safety PLC and, via standard EtherNet/IP I/O mapping, to the SCADA historian.

Q2: Is the F3SJ-A0245P14-L compatible with non-Omron safety PLCs such as Rockwell GuardLogix? Yes. The F3SJ-A0245P14-L implements the CIP Safety protocol over EtherNet/IP, which is an open standard supported by Rockwell GuardLogix, Pilz PNOZmulti 2, and other CIP Safety-capable controllers. An EDS (Electronic Data Sheet) file is available for import into Studio 5000 Logix Designer for seamless I/O configuration.

Q3: What is the network response time, and is it suitable for high-speed press applications? The F3SJ-A0245P14-L has a safety response time of ≤ 8 ms in standard mode, which meets the requirements of most press and stamping applications when combined with a correctly calculated safety distance per ISO 13855. EtherNet/IP diagnostic data is updated at the network RPI (Requested Packet Interval), configurable down to 10 ms, ensuring near-real-time visibility in SCADA and HMI systems.

Q4: What does the 12-month warranty cover, and is pre-shipment testing performed? Every F3SJ-A0245P14-L unit supplied by NANKMOS undergoes pre-shipment functional testing — including OSSD output verification, beam alignment check, and EtherNet/IP communication validation — before dispatch. The 12-month warranty covers manufacturing defects and functional failures under normal operating conditions. In-stock units are available for immediate global shipping, with lead times confirmed at order placement.

Quality & Delivery Assurance

Functional InspectionFunctional Inspection

100% tested on professional platforms to ensure stable performance.

Anti-static PackagingAnti-static Packaging

Modules are packed in anti-static bags to prevent electrostatic damage.

Secure Export PackingSecure Export Packing

Cushion protection and strong cartons ensure safe transportation.

Worldwide ShippingWorldwide Shipping

Global logistics network supports air, sea and express delivery.

Documentation CheckDocumentation Check

Part number, revision and compatibility verified before shipment.

After-sales SupportAfter-sales Support

Professional technical support to help resolve your issues.

Related Models Often Requested

View More Related Models