Functional Inspection100% tested on professional platforms to ensure stable performance.
PILZ PSS1 BMP 5/2GRUNDTRAGER RGH22 X50F00 839-034095-001 839-034098-001 is a NANKMOS industrial automation product record Listed under Other series series and Business & Industrial > Automation, Control & Flow Devices > Programmable Logic Controllers. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.
Brand names are used for identification only.
PILZ PSS1 BMP 5/2GRUNDTRAGER RGH22 X50F00 839-034095-001 839-034098-001 is a NANKMOS industrial automation product record Listed under Other series series and Business & Industrial > Automation, Control & Flow Devices > Programmable Logic Controllers. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.
| Manufacturer | PILZ |
|---|---|
| Application | Controller Processing & System Control |
| Part Number / Model | PSS1 BMP 5/2GRUNDTRAGER RGH22 X50F00 839-034095-001 839-034098-001 |
| Compatible System | Confirmed by inquiry |
| Condition Options | To Confirm |
| Module Type | Controller / CPU Module |
| Warranty | 12 Months |
| Packaging | Anti-static Bag / Secure Box |
| Shipping Methods | DHL / FedEx / UPS / Air / Sea |
| Availability | To Confirm |
| Lead Time | To Confirm |
| Documentation | Part number and revision checked before quote |
The Pilz PSS1 BMP 5/2GRUNDTRAGER (839-034095-001 / 839-034098-001) is the structural and electrical foundation of the PSS1 modular safety controller platform. In a complete PSS1 control architecture, the base rack does not operate in isolation — it is the integration point that physically and electrically unifies every functional layer of the safety system.
At the control layer, the PSS1 CPU module — such as the Pilz PSS1 CPU 0702 DP or PSS1 CPU 0702 ETH — seats directly into the base rack's primary slot, establishing the central processing and safety logic execution core. The backplane bus embedded within the BMP 5/2GRUNDTRAGER provides deterministic, low-latency signal routing between the CPU and all downstream I/O modules, ensuring that safety-critical scan cycles are maintained without communication bottlenecks.
At the I/O layer, digital input modules such as the Pilz PSS1 DI 16 24VDC and digital output modules such as the PSS1 DO 8 24VDC populate the remaining slots of the base rack. These modules interface directly with field devices — emergency stop circuits, light curtains, safety gates, and two-hand control panels — and route their signals through the backplane to the CPU for real-time safety evaluation. The slot architecture of the BMP 5/2GRUNDTRAGER supports mixed I/O configurations, enabling engineers to tailor the rack population to the specific safety function density required by the application.
At the power layer, the Pilz PSS1 PS 24VDC power supply module integrates into the rack assembly, delivering regulated 24 V DC to the backplane bus and all installed modules. Proper power architecture — including upstream 24 V DC rail protection via fused terminal blocks or Phoenix Contact PTFIX distribution blocks — ensures that voltage transients from adjacent motor drives or solenoid switching do not propagate into the safety controller backplane.
At the communication layer, the PSS1 platform supports fieldbus gateway modules including Pilz PSS1 GW PROFIBUS-DP and PSS1 GW CANopen, which install into the base rack and extend the safety controller's reach to distributed I/O nodes, variable frequency drives, and remote safety devices across the plant floor. This enables the BMP 5/2GRUNDTRAGER-based rack to serve as the safety master in a hierarchical PROFIBUS or CANopen network topology.
At the HMI layer, operator interface terminals such as the Pilz PMI v19 or third-party PROFIBUS-connected HMI panels connect to the PSS1 system via the communication gateway, providing operators with real-time safety status visualization, fault acknowledgment, and diagnostic readout without requiring direct wiring to the base rack.
At the protection and redundancy layer, the PSS1 architecture supports dual-channel input wiring and cross-monitoring between redundant CPU configurations. In high-availability applications, a secondary PSS1 rack — also built on the BMP 5/2GRUNDTRAGER base — can be configured in a hot-standby or parallel-processing topology, ensuring that a single module failure does not result in uncontrolled machine shutdown.
At the maintenance layer, the modular slot design of the BMP 5/2GRUNDTRAGER enables individual module replacement without disturbing adjacent modules or rewiring field connections. Combined with the PSS1 platform's onboard diagnostic LEDs and PROFIBUS diagnostic messaging, maintenance engineers can isolate faults to the module level within minutes, minimizing mean time to repair (MTTR) and maximizing system availability.
The Pilz PSS1 BMP 5/2GRUNDTRAGER base rack is deployed across a broad range of safety-critical industrial environments where modular, certifiable, and maintainable safety control architecture is required.
In manufacturing and machine safety applications — including robotic welding cells, stamping presses, injection molding machines, and automated assembly lines — the PSS1 base rack serves as the safety controller backbone, managing emergency stop loops, safety gate interlocks, and two-hand control circuits in compliance with ISO 13849-1 PLe / SIL 3 requirements.
In power generation and electrical substation environments, the PSS1 platform's deterministic scan cycle and SIL 3 capability make it suitable for turbine protection, generator interlock, and switchgear control applications where safety response time and diagnostic coverage are regulatory requirements.
In petrochemical and process safety installations, the BMP 5/2GRUNDTRAGER-based PSS1 rack integrates into safety instrumented systems (SIS) for burner management, emergency shutdown (ESD), and high-integrity pressure protection (HIPPS) functions, operating alongside process controllers and DCS systems via PROFIBUS-DP gateway modules.
In water treatment and utilities facilities, the PSS1 system manages pump interlock sequences, valve position monitoring, and chemical dosing safety functions, with the base rack's compact form factor enabling installation in space-constrained control panels.
In mining, metals, and heavy industry applications — including conveyor systems, crusher interlocks, and hoist safety — the PSS1 platform's robust backplane design and wide operating temperature range support reliable operation in electrically noisy, high-vibration environments.
In marine and offshore automation, the PSS1 base rack supports safety functions for engine room automation, fire and gas detection integration, and dynamic positioning safety loops, where compact panel space and deterministic safety response are critical design constraints.
Q1: Is the Pilz PSS1 BMP 5/2GRUNDTRAGER compatible with all PSS1 CPU and I/O modules? Yes. The BMP 5/2GRUNDTRAGER base rack is designed as the universal mechanical and electrical carrier for the PSS1 modular platform. It accepts all PSS1 CPU variants (including PSS1 CPU 0702 DP and ETH), all PSS1 digital and analog I/O modules, PSS1 power supply modules, and PSS1 fieldbus gateway modules. Module population must follow Pilz slot assignment rules as defined in the PSS1 system manual to ensure correct backplane bus addressing and safety function integrity.
Q2: Can the PSS1 BMP 5/2GRUNDTRAGER base rack be used in a redundant or expanded architecture? Yes. The PSS1 platform supports multi-rack expansion via rack coupling modules, allowing additional BMP base racks to be connected to a primary CPU rack for I/O expansion beyond the 5-slot capacity of a single BMP 5/2GRUNDTRAGER. For redundant CPU architectures, a second PSS1 rack can be configured in parallel, with both racks sharing I/O via the backplane bus extension. This architecture is commonly used in high-availability SIL 3 applications where continuous operation during single-module failure is required.
Q3: What warranty and supply assurance is provided for the Pilz PSS1 BMP 5/2GRUNDTRAGER? All units supplied carry a 12-Month Warranty covering manufacturing defects and functional performance. Every unit undergoes functional testing prior to dispatch to verify backplane bus integrity, slot connector condition, and mechanical fit. Stock availability is maintained for rapid fulfillment to minimize project delays. For long-term maintenance planning, cross-reference part numbers 839-034095-001 and 839-034098-001 when sourcing replacement or spare units to ensure architectural consistency across your PSS1 installation.
Functional Inspection100% tested on professional platforms to ensure stable performance.
Anti-static PackagingModules are packed in anti-static bags to prevent electrostatic damage.
Secure Export PackingCushion protection and strong cartons ensure safe transportation.
Worldwide ShippingGlobal logistics network supports air, sea and express delivery.
Documentation CheckPart number, revision and compatibility verified before shipment.
After-sales SupportProfessional technical support to help resolve your issues.