Functional Inspection100% tested on professional platforms to ensure stable performance.
GE Grid Solutions SR760 760-P1-G1-S1-HI-A20-R is a NANKMOS industrial automation product record Listed under Other series series and Business & Industrial > Automation, Control & Flow Devices. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.
Brand names are used for identification only.
GE Grid Solutions SR760 760-P1-G1-S1-HI-A20-R is a NANKMOS industrial automation product record Listed under Other series series and Business & Industrial > Automation, Control & Flow Devices. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.
| Manufacturer | GE Grid Solutions |
|---|---|
| Application | Industrial Automation Maintenance |
| Part Number / Model | SR760 760-P1-G1-S1-HI-A20-R |
| Compatible System | Confirmed by inquiry |
| Condition Options | To Confirm |
| Module Type | Automation, Control & Flow Devices |
| Warranty | 12 Months |
| Packaging | Anti-static Bag / Secure Box |
| Shipping Methods | DHL / FedEx / UPS / Air / Sea |
| Availability | To Confirm |
| Lead Time | To Confirm |
| Documentation | Part number and revision checked before quote |
The GE Multilin SR760 760-P1-G1-S1-HI-A20-R is engineered to operate as a core protection and control node within a layered industrial automation architecture. Its value is fully realized when deployed alongside complementary components that span the control, I/O, communication, power, HMI, and protection layers of a complete substation or feeder automation system.
At the control layer, the SR760 integrates seamlessly with GE's D60 Line Distance Protection Relay and the B90 Bus Differential Relay, enabling coordinated zone-selective interlocking across the feeder and bus protection scheme. The relay's RS-485 Modbus RTU port and optional DNP3 communication card (S1 slot) allow direct integration with GE's UR Series Universal Relay platform, ensuring consistent data exchange and event logging across the protection hierarchy.
At the I/O and signal layer, the SR760's high-density I/O configuration (HI, A20) supports direct wiring to GE Multilin 869 Motor Protection Relay and 339 Motor Management Relay for coordinated motor-feeder protection in MCC (Motor Control Center) applications. Signal conditioning and isolation are maintained through dedicated analog input modules, ensuring measurement accuracy even in high-noise industrial environments such as arc furnace substations or variable-frequency drive (VFD) installations.
At the communication layer, the S1 communication slot supports protocol cards for IEC 60870-5-103 and DNP3, enabling the SR760 to report to SCADA systems via GE's PMCS (Power Management Control System) or third-party EMS/DMS platforms. When paired with a GE MDS SD9 or similar industrial serial-to-Ethernet gateway, the relay participates in a fully networked substation automation architecture compliant with IEC 61850 GOOSE messaging requirements through protocol conversion.
At the power supply layer, the P1 power supply module (100–240 V AC / 125–250 V DC) ensures operational continuity during AC supply interruptions, drawing from station battery systems typically supported by GE SG Series or equivalent 125 V DC battery charger systems. This dual-source power architecture is critical for maintaining relay availability during grid disturbances.
At the HMI and diagnostics layer, the SR760's front-panel LCD and LED indicators provide local status visibility, while the rear RS-485 port connects to GE's EnerVista SR760 Setup Software for configuration, event record retrieval, oscillography download, and firmware management. Remote HMI access is further extended through integration with GE's Multilin Universal Relay Communications (MURC) software suite, enabling centralized fleet management of SR-series relays across multiple substations.
At the protection and redundancy layer, the SR760 supports auto-reclose (79) and breaker failure (50BF) functions, coordinating with upstream GE L90 Line Current Differential Relay or downstream GE 489 Generator Management Relay to form a complete protection chain. In ring-bus or breaker-and-a-half configurations, the relay's directional overcurrent elements (67/67N) provide selective fault clearance without compromising system continuity.
At the maintenance and lifecycle layer, the SR760's modular firmware architecture supports field upgrades without hardware replacement, reducing total cost of ownership over a 15–20 year substation lifecycle. All units supplied by NANKMOS are pre-tested against GE factory acceptance test (FAT) criteria and covered under a 12-Month Warranty from the date of shipment, with full traceability documentation available upon request.
The GE Multilin SR760 760-P1-G1-S1-HI-A20-R serves as a versatile feeder protection platform across a broad range of industrial and utility applications:
Electric Power Distribution: In utility distribution substations, the SR760 provides primary feeder protection for 11 kV, 33 kV, and 66 kV feeders, coordinating with upstream transmission protection via zone-selective interlocking. Its auto-reclose capability (79) minimizes outage duration for transient faults, improving SAIDI and SAIFI metrics for distribution system operators.
Petrochemical and Refinery Plants: In high-voltage switchgear rooms of petrochemical complexes, the SR760 protects medium-voltage feeders supplying critical process loads including compressors, pumps, and heat exchangers. Its directional earth fault protection (67N) is particularly valuable in resistance-grounded or isolated-neutral systems common in hazardous area installations.
Water and Wastewater Treatment: Municipal water authorities deploy the SR760 to protect feeder circuits supplying pump stations, aeration blowers, and UV disinfection systems. The relay's demand metering and power quality monitoring functions support energy management reporting required under ISO 50001 frameworks.
Mining and Mineral Processing: In underground and open-pit mining operations, the SR760 protects feeder circuits in mobile substation configurations, where robust construction (-40°C to +60°C operating range) and high-density I/O are essential for reliable operation in harsh environments with frequent load switching and motor starting transients.
Metallurgy and Steel Production: In electric arc furnace (EAF) substations, the SR760's fast overcurrent response (50/51) and harmonic-tolerant measurement algorithms maintain protection selectivity despite the highly distorted current waveforms characteristic of arc furnace loads.
Marine and Offshore: Offshore platform electrical systems and vessel power management systems utilize the SR760 for feeder protection in medium-voltage switchboards, where compact form factor, wide temperature range, and dual-source power supply (P1) meet DNV GL and ABS classification society requirements.
Packaging and Discrete Manufacturing: In automated production facilities, the SR760 protects feeder circuits supplying robotic work cells, conveyor systems, and press lines, with its event recording and oscillography functions supporting rapid fault diagnosis to minimize production downtime.
Q1: Is the GE Multilin SR760 760-P1-G1-S1-HI-A20-R compatible with IEC 61850 SCADA integration? The SR760 natively supports Modbus RTU and DNP3 via its S1 communication slot. For IEC 61850 GOOSE and MMS integration, a protocol gateway such as a GE MDS or equivalent serial-to-IEC 61850 converter is required. This approach is widely deployed in brownfield substation automation upgrades where legacy SR-series relays are retained within an IEC 61850 architecture. NANKMOS can advise on compatible gateway configurations based on your SCADA platform requirements.
Q2: What are the installation and commissioning requirements for the SR760 in a new feeder protection panel? The SR760 mounts in a standard 19-inch rack or panel flush-mount cutout. Commissioning requires GE's EnerVista SR760 Setup Software (available from GE Grid Solutions) for settings upload, CT/VT ratio configuration, and protection function parameterization. Secondary injection testing using a relay test set (e.g., Omicron CMC series) is recommended to verify all protection elements prior to energization. NANKMOS supplies units with factory settings cleared and ready for site-specific configuration, with full test reports available upon request.
Q3: What warranty and long-term support does NANKMOS provide for the SR760? All SR760 units supplied by NANKMOS are covered by a 12-Month Warranty from the date of shipment, covering manufacturing defects and functional failures under normal operating conditions. Each unit undergoes pre-shipment functional testing including power-on verification, communication port testing, and I/O continuity checks. For long-term support, NANKMOS maintains stock of SR760 units and compatible accessories to support emergency replacement requirements with short lead times. Extended support agreements and spare parts sourcing assistance are available upon request.
Functional Inspection100% tested on professional platforms to ensure stable performance.
Anti-static PackagingModules are packed in anti-static bags to prevent electrostatic damage.
Secure Export PackingCushion protection and strong cartons ensure safe transportation.
Worldwide ShippingGlobal logistics network supports air, sea and express delivery.
Documentation CheckPart number, revision and compatibility verified before shipment.
After-sales SupportProfessional technical support to help resolve your issues.