Global Industrial Automation Sourcing

EN  /  CN
NANKMOSEmpower Industry. Advance Future.
Send Inquiry

GE Grid Solutions UR9NV UR6SH Power Supply Module

GE Grid Solutions UR9NV UR6SH is a NANKMOS industrial automation product record Listed under Power Supply for UR Series series and Business & Industrial > Automation, Control & Flow Devices > Programmable Logic Controllers. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.

Brand names are used for identification only.
Product Snapshot

Availability & Sourcing Details

GE Grid Solutions UR9NV UR6SH is a NANKMOS industrial automation product record Listed under Power Supply for UR Series series and Business & Industrial > Automation, Control & Flow Devices > Programmable Logic Controllers. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.

Power Module PLC System Power Supply for UR Series GE Grid Solutions
Application
Control System Power Support
Condition Options
New / Used / Refurbished
Availability
Confirmed by Email
Warranty
12 Months
Packaging
Anti-static Bag / Secure Box
Shipping
DHL / FedEx / UPS / Air / Sea

Product Information

ManufacturerGE Grid Solutions
ApplicationControl System Power Support
Part Number / ModelUR9NV UR6SH
Compatible SystemPower Supply for UR Series
SeriesPower Supply for UR Series
Condition OptionsTo Confirm
Module TypePower Supply Module
Warranty12 Months
PackagingAnti-static Bag / Secure Box
Shipping MethodsDHL / FedEx / UPS / Air / Sea
AvailabilityTo Confirm
Lead TimeTo Confirm
DocumentationPart number and revision checked before quote
Product Details

UR9NV UR6SH Product Description

The GE UR9NV is a dedicated power supply module engineered for seamless integration within the GE UR Series Universal Relay platform — one of the most widely deployed protection relay architectures in transmission substations, generation facilities, and industrial power systems worldwide. Designed to deliver stable, conditioned DC power to the UR Series chassis backplane, the UR9NV ensures that every module in the rack — from the CPU card and I/O modules to the communications processor and analog input cards — operates within its specified voltage tolerance under all load conditions. In mission-critical protection relay systems, power supply integrity is not a secondary concern; it is the foundational layer upon which system reliability, redundancy, and long-term maintainability are built.

The UR9NV is engineered to meet the demanding requirements of IEC 61850-compliant substation automation environments, where power quality directly affects relay response time, event logging accuracy, and GOOSE message transmission reliability. Its wide input voltage range accommodates both 125 VDC and 250 VDC station battery systems, making it suitable for brownfield retrofits and greenfield substation designs alike. The module's internal architecture incorporates input filtering, inrush current limiting, and output regulation circuitry that collectively suppress conducted interference from adjacent switchgear, capacitor bank switching, and bus fault events — conditions that routinely stress power supply components in live substation environments.

Within the UR Series rack, the UR9NV operates in close coordination with the UR6SH chassis backplane, which distributes regulated power to all installed modules including the UR6PP CPU module, UR6CT current transformer input cards, UR6VT voltage transformer input cards, UR6D8 digital output modules, and UR6C2 communications processor cards. This tightly integrated power distribution architecture eliminates the need for external DC-DC converters or supplementary power conditioning equipment, reducing panel footprint and simplifying commissioning. Engineers deploying distance protection, differential protection, or bus protection schemes based on the UR platform can rely on the UR9NV to maintain power rail stability across the full operating temperature range of −40°C to +60°C.

For systems requiring redundant power supply configurations — a standard requirement in N-1 secure substation designs and critical infrastructure protection applications — the UR9NV supports dual power supply installation within compatible UR chassis variants. Redundant UR9NV modules operate in active-standby mode, with automatic switchover that occurs without interrupting relay protection functions or resetting the CPU module. This architecture is particularly valuable in 500 kV and 220 kV transmission substations where relay unavailability during maintenance windows carries significant operational risk. The seamless failover capability also supports hot-swap replacement of a failed power supply module without de-energizing the relay panel, a feature that maintenance teams in 24/7 operational environments depend on.

From a system integration perspective, the UR9NV is fully compatible with GE's EnerVista UR Setup software, which provides real-time monitoring of power supply status, input voltage levels, and module health diagnostics through the relay's front panel HMI or remote SCADA interface. When integrated with a station-level IEC 61850 gateway — such as the GE D20MX or a compatible third-party RTU — power supply status data can be mapped to SCADA points and included in substation-wide asset health monitoring dashboards. This level of diagnostic transparency supports condition-based maintenance strategies that reduce unplanned outages and extend the operational life of the protection relay system as a whole.

The UR9NV is stocked and available for immediate dispatch, with standard lead times of 1–3 business days for in-stock units. Each module is subject to pre-shipment functional testing covering input voltage acceptance, output voltage regulation, ripple and noise measurement, and thermal performance verification. All UR9NV units supplied by NANKMOS are covered by a 12-Month Warranty against manufacturing defects and functional failures, with technical support available throughout the warranty period. The module ships in original or equivalent protective packaging with full documentation, including the GE UR Series instruction manual reference and hardware revision identification.

The UR9NV power supply module is the enabling layer for a complete UR Series protection relay system. In a fully configured UR chassis, the UR9NV powers the UR6PP CPU module, which executes protection algorithms including distance, differential, overcurrent, and directional earth fault functions. The CPU module communicates with the station automation network via the UR6C2 communications processor, which supports IEC 61850 GOOSE messaging, DNP3, and Modbus TCP/IP — protocols essential for integration with substation RTUs, protection management systems, and SCADA platforms.

Analog inputs are handled by the UR6CT current transformer input card and the UR6VT voltage transformer input card, which digitize primary system quantities and feed them to the CPU for real-time protection calculations. Digital outputs — trip signals, alarm contacts, and control outputs — are routed through the UR6D8 digital output module, which interfaces directly with circuit breaker trip coils, lockout relays, and annunciator panels. The UR6SH chassis backplane ties all modules together, distributing power from the UR9NV and providing the high-speed inter-module communication bus.

For substation-level integration, the UR Series rack is typically installed alongside a GE D20MX RTU or equivalent IEC 61850 gateway, which aggregates protection relay data and forwards it to the energy management system. Panel-level HMI functions are supported by the relay's built-in front panel display or by an external GE Multilin HMI terminal connected via the relay's RS-232 or Ethernet port. In redundant protection schemes, a second UR chassis — also powered by a dedicated UR9NV — provides backup protection coverage, with both systems synchronized via inter-relay communications using the UR6C2 communications card and fiber-optic direct transfer trip channels.

Power supply integrity across the entire panel is further supported by a station battery system with a GE DECS-250 battery charger or equivalent DC UPS, ensuring that the UR9NV input voltage remains within specification during AC supply interruptions. Signal isolation between the relay panel and the station control system is maintained through interposing relay modules and signal isolators installed on the terminal block rail adjacent to the UR chassis, preventing ground loop interference from affecting relay measurement accuracy.

Transmission Substation Protection: In 110 kV to 500 kV transmission substations, the UR9NV-powered UR Series relay provides primary and backup protection for transmission lines, transformers, and bus sections. The stable power supply ensures that distance protection zones and differential protection operate with consistent timing accuracy across all fault conditions, including close-in faults and evolving fault scenarios.

Generation Facility Protection: At thermal, hydro, and wind generation facilities, the UR Series platform — powered by the UR9NV — provides generator protection, transformer protection, and unit auxiliary transformer protection. The wide input voltage range accommodates the variable DC bus conditions common in generation facility battery systems, particularly during generator startup and shutdown sequences.

Industrial Power Systems: In petrochemical plants, steel mills, mining operations, and large manufacturing facilities, the UR9NV supports UR Series relays deployed for motor protection, feeder protection, and bus protection in medium-voltage switchgear lineups. The hot-swap capability is particularly valued in continuous-process industries where relay panel maintenance must be performed without process interruption.

Water and Wastewater Treatment: Municipal water treatment facilities and pumping stations use the UR Series platform for pump motor protection and feeder protection. The UR9NV's wide operating temperature range supports installation in outdoor switchgear enclosures and remote pumping station panels where environmental conditions are less controlled than in dedicated relay rooms.

Marine and Offshore Applications: Offshore platforms and marine vessel power systems deploy the UR Series for generator protection and bus tie protection. The UR9NV's robust input filtering and wide voltage acceptance range accommodate the power quality variations inherent in isolated marine power systems, including harmonic distortion from variable-frequency drives and generator AVR interactions.

Q1: Can the UR9NV be used in a redundant power supply configuration, and what is the switchover behavior? Yes. Compatible UR Series chassis variants support installation of two UR9NV modules in designated power supply slots. The modules operate in active-standby mode with automatic, bumpless switchover upon detection of a primary supply failure. The switchover does not interrupt relay protection functions, reset the CPU module, or generate a trip output. Switchover events are logged in the relay's event recorder and can be mapped to SCADA alarm points via the IEC 61850 or DNP3 interface. This configuration meets the redundancy requirements of IEC 61850-4 engineering guidelines for protection relay power supply systems.

Q2: Is the UR9NV compatible with both 125 VDC and 250 VDC station battery systems, and are there any derating requirements? The UR9NV is designed with a wide input voltage range that accommodates both 125 VDC and 250 VDC nominal station battery systems, including the voltage excursions that occur during battery charging (up to approximately 140 VDC and 280 VDC respectively) and during battery discharge under load. No output derating is required across the full input voltage range within the specified operating temperature envelope of −40°C to +60°C. For installations in high-ambient-temperature environments above +55°C, consult the GE UR Series hardware manual for any applicable thermal derating guidelines specific to the chassis configuration.

Q3: What does the 12-Month Warranty cover, and what is the process for warranty claims on UR9NV units supplied by NANKMOS? All UR9NV units supplied by NANKMOS are covered by a 12-Month Warranty from the date of shipment, covering manufacturing defects, component failures, and functional non-conformance to GE UR Series specifications. The warranty does not cover damage resulting from incorrect installation, overvoltage events beyond the specified input range, or physical damage during handling. To initiate a warranty claim, contact NANKMOS at [email protected] or +86 18359268345 with the unit serial number, purchase order reference, and a description of the observed fault. NANKMOS will arrange for unit inspection, repair, or replacement within the warranty period, with technical support available throughout the process.

Quality & Delivery Assurance

Functional InspectionFunctional Inspection

100% tested on professional platforms to ensure stable performance.

Anti-static PackagingAnti-static Packaging

Modules are packed in anti-static bags to prevent electrostatic damage.

Secure Export PackingSecure Export Packing

Cushion protection and strong cartons ensure safe transportation.

Worldwide ShippingWorldwide Shipping

Global logistics network supports air, sea and express delivery.

Documentation CheckDocumentation Check

Part number, revision and compatibility verified before shipment.

After-sales SupportAfter-sales Support

Professional technical support to help resolve your issues.

Related Models Often Requested

View More Related Models