Functional Inspection100% tested on professional platforms to ensure stable performance.
Bosch Rexroth 1070080132-103 is a NANKMOS industrial automation product record Listed under Other series series and Drives. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.
Brand names are used for identification only.
Bosch Rexroth 1070080132-103 is a NANKMOS industrial automation product record Listed under Other series series and Drives. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.
| Manufacturer | Bosch Rexroth |
|---|---|
| Application | Industrial Network Communication |
| Part Number / Model | 1070080132-103 |
| Compatible System | Confirmed by inquiry |
| Condition Options | To Confirm |
| Module Type | Communication Module |
| Warranty | 12 Months |
| Packaging | Anti-static Bag / Secure Box |
| Shipping Methods | DHL / FedEx / UPS / Air / Sea |
| Availability | To Confirm |
| Lead Time | To Confirm |
| Documentation | Part number and revision checked before quote |
The Bosch Rexroth 1070080132-103 is a precision-engineered industrial network interface module designed for seamless integration within the IndraControl servo and drive architecture. Built to bridge field-level devices with upper-layer control and monitoring systems, this module serves as a critical data link in smart factory environments where real-time communication, protocol reliability, and system transparency are non-negotiable. Whether deployed in a high-speed servo axis application or a distributed motion control network, the 1070080132-103 delivers the connectivity backbone that modern automation sites demand.
In today's industrial landscape, the ability to move data accurately and continuously across every layer of the automation pyramid — from sensor and actuator to SCADA and MES — defines the competitive edge of a smart factory. The 1070080132-103 is engineered precisely for this role, supporting SERCOS (Serial Real-time Communication System) and PROFIBUS protocols that are foundational to Bosch Rexroth's IndraControl ecosystem. These protocols ensure deterministic, low-latency data exchange between the drive controller and the PLC or motion controller, enabling tight synchronisation across multi-axis systems.
The 1070080132-103 sits at the intersection of field-level drive control and plant-wide data visibility. In a typical smart factory deployment, the data flow begins at the servo motor and encoder level, where position, velocity, and torque feedback are captured in real time. This data travels via the SERCOS ring to the Bosch Rexroth IndraControl XM22 or IndraControl L45 motion controller, which processes axis commands and synchronises multi-drive sequences with microsecond precision.
From the motion controller, process data is forwarded upstream via PROFIBUS DP to a Siemens S7-300 or S7-400 PLC, where the broader production logic resides. The PLC aggregates drive status, fault codes, and cycle data, then passes structured information to an HMI panel — such as a Bosch Rexroth IndraControl VPP or a third-party SCADA terminal — for operator visualisation and alarm management.
For facilities running a WinCC or InTouch SCADA platform, the 1070080132-103 enables the drive network to appear as a transparent data source, feeding real-time axis states, energy consumption metrics, and fault histories into the supervisory layer. This integration supports predictive maintenance workflows, where anomalies in torque ripple or velocity deviation trigger automated alerts before mechanical failure occurs.
In distributed architectures, the module also interfaces with remote I/O stations — such as Bosch Rexroth's own I/O expansion modules or third-party PROFIBUS remote I/O racks — extending the control network to field cabinets and junction boxes across the production floor. Edge gateway devices, including Hilscher netTAP NT 100 or similar PROFIBUS-to-Ethernet gateways, can bridge the drive data into an OPC-UA or MQTT stream for cloud-based analytics and digital twin applications.
Variable frequency drives (VFDs) and servo amplifiers within the same PROFIBUS segment — such as Bosch Rexroth IndraDrive Cs or IndraDrive Mi units — share the same network backbone, allowing the 1070080132-103 to act as a cohesive link across the entire drive train. Industrial Ethernet switches with PROFIBUS-compatible managed ports ensure network segmentation and traffic prioritisation, maintaining deterministic performance even under high-load conditions.
Power supply modules and 24 VDC distribution units within the control cabinet are monitored via the same data chain, with energy management data routed through the SCADA layer for consumption tracking and load balancing. The complete data loop — from encoder signal to cloud dashboard — is made possible by the reliable, field-proven connectivity of the 1070080132-103.
Many industrial sites operate with a fragmented automation landscape: legacy PROFIBUS devices alongside newer SERCOS-based servo systems, proprietary HMI platforms that cannot natively read drive diagnostics, and SCADA systems that receive only summary-level data rather than granular axis telemetry. The 1070080132-103 directly addresses these integration challenges.
Protocol Fragmentation: By supporting both SERCOS and PROFIBUS within the IndraControl framework, this module eliminates the need for external protocol converters between the drive layer and the PLC network. Data flows natively, reducing latency and eliminating translation errors that can corrupt position or velocity setpoints.
Data Silos: Drive-level diagnostics — including following error, overtemperature warnings, and encoder fault codes — are surfaced directly to the SCADA and HMI layers, breaking down the information barriers that typically isolate the drive network from the plant operations team.
Remote Monitoring: With PROFIBUS connectivity feeding into an OPC-UA gateway, maintenance engineers can access live drive parameters from a remote workstation or mobile device, enabling off-site diagnostics without requiring physical access to the control cabinet.
Production Line Transparency: Cycle time data, axis utilisation rates, and fault frequency statistics are made available to MES and ERP systems, supporting OEE (Overall Equipment Effectiveness) calculations and production reporting without manual data entry.
Alarm Traceability: Timestamped fault logs from the drive network are forwarded to the SCADA historian, enabling root-cause analysis of production stoppages and supporting continuous improvement initiatives.
System Scalability: The PROFIBUS segment supported by the 1070080132-103 can accommodate up to 126 nodes, allowing the network to grow as additional drives, I/O modules, and sensors are added to the production line without requiring infrastructure redesign.
Q1: What communication protocols does the 1070080132-103 support, and are they compatible with third-party PLCs?The 1070080132-103 supports SERCOS for real-time drive-to-controller communication and PROFIBUS DP for integration with the broader PLC network. PROFIBUS DP is an open, IEC-standardised protocol widely supported by Siemens, ABB, Schneider Electric, and other major PLC manufacturers, ensuring broad compatibility beyond the Bosch Rexroth ecosystem.
Q2: What is the typical communication latency on the SERCOS ring with this module?SERCOS operates with cycle times as low as 62.5 µs in high-performance configurations, providing deterministic, jitter-free communication suitable for multi-axis synchronisation and high-speed servo applications. Actual cycle time depends on the number of drives on the ring and the IndraControl firmware version in use.
Q3: Can this module be integrated into an existing SCADA or remote monitoring system?Yes. Via PROFIBUS DP and an appropriate gateway (e.g., PROFIBUS-to-OPC-UA or PROFIBUS-to-Modbus TCP), the 1070080132-103 can feed drive data into SCADA platforms such as Siemens WinCC, Wonderware InTouch, or Ignition. This enables real-time visualisation, alarm management, and historical data logging without modifying the core drive configuration.
Q4: What quality assurance and warranty coverage is provided with this module?Every 1070080132-103 unit supplied by NANKMOS undergoes functional testing prior to shipment, verifying communication integrity, interface connectivity, and firmware compatibility. A 12-month warranty is included as standard, covering manufacturing defects and verified functional failures. In-stock units are available for immediate dispatch to global destinations.
Functional Inspection100% tested on professional platforms to ensure stable performance.
Anti-static PackagingModules are packed in anti-static bags to prevent electrostatic damage.
Secure Export PackingCushion protection and strong cartons ensure safe transportation.
Worldwide ShippingGlobal logistics network supports air, sea and express delivery.
Documentation CheckPart number, revision and compatibility verified before shipment.
After-sales SupportProfessional technical support to help resolve your issues.