Global Industrial Automation Sourcing

EN  /  CN
NANKMOSEmpower Industry. Advance Future.
Send Inquiry

MKS Instruments 1179AX11CR14V26 PF802-ADS E17601520 E1929945

MKS Instruments 1179AX11CR14V26 PF802-ADS E17601520 E19299450 is a NANKMOS industrial automation product record Listed under Other series series and Business & Industrial > Automation, Control & Flow Devices > Programmable Logic Controllers. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.

Brand names are used for identification only.
Product Snapshot

Availability & Sourcing Details

MKS Instruments 1179AX11CR14V26 PF802-ADS E17601520 E19299450 is a NANKMOS industrial automation product record Listed under Other series series and Business & Industrial > Automation, Control & Flow Devices > Programmable Logic Controllers. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.

Controller Module PLC System MKS Instruments
Application
Controller Processing & System Control
Condition Options
New / Used / Refurbished
Availability
Confirmed by Email
Warranty
12 Months
Packaging
Anti-static Bag / Secure Box
Shipping
DHL / FedEx / UPS / Air / Sea

Product Information

ManufacturerMKS Instruments
ApplicationController Processing & System Control
Part Number / Model1179AX11CR14V26 PF802-ADS E17601520 E19299450
Compatible SystemConfirmed by inquiry
Condition OptionsTo Confirm
Module TypeController / CPU Module
Warranty12 Months
PackagingAnti-static Bag / Secure Box
Shipping MethodsDHL / FedEx / UPS / Air / Sea
AvailabilityTo Confirm
Lead TimeTo Confirm
DocumentationPart number and revision checked before quote
Product Details

1179AX11CR14V26 PF802-ADS E17601520 E19299450 Product Description

The MKS 1179AX11CR14V26 is a precision analog Mass Flow Controller (MFC) engineered for seamless integration into modern smart factory data architectures. Designed by MKS Instruments, this unit delivers stable, repeatable gas flow control with native support for 0–5 VDC and 4–20 mA analog protocols, making it a reliable node in any industrial signal chain — from field-level sensors to SCADA supervisory systems. Whether deployed in semiconductor fabrication, petrochemical processing, or precision gas delivery systems, the 1179AX11CR14V26 bridges the gap between physical process control and digital data visibility.

In a connected factory environment, every device must contribute to the data flow. The MKS 1179AX11CR14V26 outputs real-time flow rate signals that feed directly into PLC analog input modules — such as Siemens S7-1200 AI cards or Allen-Bradley 1769-IF4 CompactLogix modules — enabling closed-loop control logic without additional signal conditioning. Its 4–20 mA current loop output is inherently noise-immune over long cable runs, a critical advantage in electrically noisy industrial environments where signal integrity directly impacts process yield.

The MKS 1179AX11CR14V26 sits at the field device layer of a multi-tier industrial data architecture. Its analog output signal is the starting point of a data chain that ultimately reaches enterprise-level MES and ERP systems. Here is how a typical smart factory data flow is constructed around this MFC:

Signal Acquisition: The 1179AX11CR14V26 measures gas flow and outputs a proportional 0–5 V or 4–20 mA signal. This signal is wired to an analog input module — for example, a Siemens ET 200SP AI 4xU/I 2-wire remote I/O module or an Advantech ADAM-6017 analog input module with Modbus TCP output. These modules digitize the analog signal and make it available on the industrial network.

Protocol Conversion and Network Transmission: Where the PLC or DCS does not natively support the analog signal format, a protocol gateway such as the Moxa MGate MB3180 (Modbus RTU to Modbus TCP) or the HMS Anybus Communicator can bridge the field signal to higher-level industrial Ethernet networks including PROFINET, EtherNet/IP, or Modbus TCP. This enables the MFC's real-time flow data to be transmitted across the plant network without signal degradation.

PLC Control Logic: The digitized flow value is processed by the PLC — such as an Allen-Bradley ControlLogix L73 or a Siemens S7-1500 CPU 1515 — which executes closed-loop PID control. The PLC compares the actual flow rate from the 1179AX11CR14V26 against the setpoint defined in the recipe management system and adjusts the analog command signal accordingly, maintaining precise gas delivery throughout the process cycle.

HMI Visualization: Operators monitor the MFC's real-time flow rate on an HMI panel — such as a Siemens SIMATIC TP1200 Comfort or a Weintek MT8102iE — where trend graphs, alarm thresholds, and setpoint adjustments are accessible. The HMI communicates with the PLC over PROFINET or EtherNet/IP, ensuring that the flow data displayed is always synchronized with the physical process.

SCADA Integration and Remote Diagnostics: At the supervisory level, platforms such as Ignition SCADA by Inductive Automation or Wonderware System Platform aggregate flow data from multiple MFCs across the production line. Historical trending, batch reporting, and alarm management are handled at this layer. Remote engineers can access live flow data, review alarm logs, and perform remote diagnostics without being physically present on the production floor — a key requirement for multi-site semiconductor and specialty gas operations.

Edge Gateway and Cloud Connectivity: For facilities implementing IIoT strategies, an edge gateway such as the Advantech ECU-1251 or Moxa UC-8112 can collect data from multiple analog MFCs via Modbus TCP and forward aggregated datasets to cloud platforms (AWS IoT, Azure IoT Hub) for long-term analytics, predictive maintenance modeling, and OEE calculation. The 1179AX11CR14V26's stable analog output ensures consistent data quality at the edge layer.

Power Infrastructure: Reliable operation of the MFC and its associated I/O modules depends on clean, stable DC power. Industrial DIN-rail power supplies such as the Phoenix Contact QUINT-PS/1AC/24DC/10 or MEAN WELL DR-120-24 provide the regulated ±15 VDC and 24 VDC required by the MFC and its signal conditioning hardware, ensuring uninterrupted data flow even during grid fluctuations.

Many industrial facilities face persistent data gaps that undermine production transparency and process control. The MKS 1179AX11CR14V26, when properly integrated, addresses several of the most common challenges:

Protocol Fragmentation: Legacy analog devices and modern digital networks often cannot communicate directly. By pairing the 1179AX11CR14V26 with an analog-to-Modbus gateway, facilities can unify their field device data onto a single industrial Ethernet backbone, eliminating the protocol silos that prevent cross-system visibility.

Data Islands and Production Blind Spots: Without real-time flow data from MFCs, process engineers cannot detect drift, contamination events, or equipment degradation until a batch failure occurs. The 1179AX11CR14V26's continuous analog output, when digitized and integrated into SCADA, provides the real-time visibility needed to catch anomalies before they become yield losses.

Remote Monitoring Limitations: In facilities where engineers cannot be on-site 24/7, remote access to MFC performance data is essential. By routing the 1179AX11CR14V26's data through a SCADA system with VPN-secured remote access, process engineers can monitor gas flow, review alarm histories, and adjust setpoints from any location — reducing response time to process deviations from hours to minutes.

Production Line Transparency: Integrating the MFC's data into an MES or ERP system enables recipe-driven automation, where gas flow setpoints are automatically loaded for each product batch, and actual flow data is recorded for traceability and compliance reporting. This closes the loop between process execution and production planning.

Alarm Tracking and Escalation: SCADA alarm management systems can be configured to trigger notifications when the 1179AX11CR14V26's flow reading deviates beyond defined limits — alerting operators via HMI, email, or SMS. This structured alarm response reduces unplanned downtime and supports root cause analysis.

System Scalability: As production capacity expands, additional MKS 1179-series MFCs can be added to the analog I/O network without architectural changes. The standardized 4–20 mA interface ensures that new devices integrate seamlessly with existing PLC programs and SCADA configurations, protecting the facility's automation investment.

Q1: What communication protocols does the MKS 1179AX11CR14V26 support natively?The 1179AX11CR14V26 uses analog protocols: 0–5 VDC setpoint/readback and 4–20 mA current loop. It does not natively support digital fieldbus protocols such as Modbus RTU, PROFIBUS, or EtherNet/IP. However, by connecting its analog output to a protocol gateway (e.g., Advantech ADAM-4117 or Moxa MGate series), the flow data can be converted to Modbus TCP or other digital protocols for integration into PLC, SCADA, and HMI systems.

Q2: How is network stability and signal integrity maintained over long cable runs?The 4–20 mA current loop output of the 1179AX11CR14V26 is inherently resistant to electromagnetic interference and voltage drop over cable distances up to several hundred meters. For installations in high-noise environments (near VFDs, servo drives, or high-voltage switchgear), shielded twisted-pair cable with proper grounding at one end is recommended. This ensures that the flow signal arriving at the PLC analog input module accurately reflects the actual gas flow rate without noise-induced errors.

Q3: Can the MKS 1179AX11CR14V26 be integrated into an existing SCADA or remote diagnostics system?Yes. The MFC's analog output can be connected to any PLC or DCS with analog input capability, and the digitized data can then be published to SCADA platforms such as Ignition, Wonderware, or iFIX via OPC-UA or Modbus TCP. Remote diagnostics — including real-time flow trending, alarm acknowledgment, and setpoint adjustment — can be performed through the SCADA client interface over a secured industrial network or VPN connection.

Q4: What does the 12-month warranty cover, and how is pre-shipment testing conducted?Every MKS 1179AX11CR14V26 unit supplied by NANKMOS is covered by a 12-month warranty from the date of shipment. Pre-shipment testing includes functional verification of the analog setpoint response, flow accuracy calibration check, and connector integrity inspection. Units that do not meet MKS Instruments' original performance specifications are not shipped. In the event of a warranty claim, NANKMOS provides technical support and coordinates replacement or repair to minimize production downtime.

Quality & Delivery Assurance

Functional InspectionFunctional Inspection

100% tested on professional platforms to ensure stable performance.

Anti-static PackagingAnti-static Packaging

Modules are packed in anti-static bags to prevent electrostatic damage.

Secure Export PackingSecure Export Packing

Cushion protection and strong cartons ensure safe transportation.

Worldwide ShippingWorldwide Shipping

Global logistics network supports air, sea and express delivery.

Documentation CheckDocumentation Check

Part number, revision and compatibility verified before shipment.

After-sales SupportAfter-sales Support

Professional technical support to help resolve your issues.

Related Models Often Requested

View More Related Models