Global Industrial Automation Sourcing

EN  /  CN
NANKMOSEmpower Industry. Advance Future.
Send Inquiry

Bosch Rexroth BM-DP12 1070075887-304

Bosch Rexroth BM-DP12 1070075887-304 is a NANKMOS industrial automation product record Listed under Other series series and Business & Industrial > Automation, Control & Flow Devices > Programmable Logic Controllers. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.

Brand names are used for identification only.
Product Snapshot

Availability & Sourcing Details

Bosch Rexroth BM-DP12 1070075887-304 is a NANKMOS industrial automation product record Listed under Other series series and Business & Industrial > Automation, Control & Flow Devices > Programmable Logic Controllers. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.

Controller Module PLC System Bosch Rexroth
Application
Controller Processing & System Control
Condition Options
New / Used / Refurbished
Availability
Confirmed by Email
Warranty
12 Months
Packaging
Anti-static Bag / Secure Box
Shipping
DHL / FedEx / UPS / Air / Sea

Product Information

ManufacturerBosch Rexroth
ApplicationController Processing & System Control
Part Number / ModelBM-DP12 1070075887-304
Compatible SystemConfirmed by inquiry
Condition OptionsTo Confirm
Module TypeController / CPU Module
Warranty12 Months
PackagingAnti-static Bag / Secure Box
Shipping MethodsDHL / FedEx / UPS / Air / Sea
AvailabilityTo Confirm
Lead TimeTo Confirm
DocumentationPart number and revision checked before quote
Product Details

BM-DP12 1070075887-304 Product Description

The Bosch Rexroth BM-DP12 (Part No. 1070075887-304) is a dedicated PROFIBUS DP communication interface module engineered for seamless integration within the IndraControl modular control platform. Designed to serve as the fieldbus backbone connector between the controller layer and distributed I/O or drive systems, the BM-DP12 enables deterministic, high-speed cyclic data exchange across complex automation architectures. Whether deployed in discrete manufacturing, process control, or energy management environments, this module delivers the communication reliability, diagnostic transparency, and architectural scalability that modern industrial systems demand.

In a fully layered automation architecture, the BM-DP12 occupies a critical position at the communication layer — bridging the IndraControl CPU (such as the IndraControl L25, L45, or L65 series) with field-level devices including distributed I/O stations, servo drives, frequency inverters, and intelligent sensors. Its PROFIBUS DP master/slave capability ensures that control signals, process values, and diagnostic data flow with sub-millisecond cycle consistency, supporting both standard DP-V0 cyclic communication and DP-V1 acyclic parameter access for advanced device management.

The module's rack-mount form factor integrates directly into the IndraControl backplane system, sharing the internal system bus with CPU modules, power supply units, and supplementary communication cards. This tight hardware integration eliminates external wiring complexity, reduces cabinet footprint, and ensures that the BM-DP12 participates fully in the platform's coordinated diagnostics and fault-management framework — a key advantage for engineers commissioning multi-axis or multi-zone control systems.

The BM-DP12 achieves its full value when considered as a component within a cohesive, multi-layer automation platform rather than a standalone communication card. In a typical IndraControl-based control cabinet, the module operates alongside the IndraControl L45 or L65 CPU as the master controller, coordinating real-time task execution and fieldbus management. The IndraControl PS power supply module provides regulated 24 VDC to the backplane, ensuring stable operation of the BM-DP12 and co-installed modules under variable load conditions.

At the I/O layer, the BM-DP12 connects to Rexroth Inline I/O stations (such as the IL series distributed I/O nodes) via the PROFIBUS DP segment, enabling remote digital and analog signal acquisition without additional point-to-point wiring. For drive integration, the module communicates directly with IndraDrive C (HCS) and IndraDrive M (HMS/HMD) servo drive systems, transmitting motion commands and receiving status feedback within the same PROFIBUS cycle — a configuration widely used in multi-axis coordinated motion applications.

Where OPC-UA or Ethernet-based supervisory connectivity is required, the IndraControl XM or CML65 communication gateway can be co-deployed on the same backplane, providing parallel fieldbus and Ethernet paths without disrupting the PROFIBUS DP segment managed by the BM-DP12. For HMI integration, Rexroth IndraControl V (ICV) operator panels connect to the supervisory Ethernet layer, while the BM-DP12 continues to manage field-level cyclic communication independently — preserving determinism at the control layer.

Signal conditioning and isolation are addressed through Phoenix Contact or Weidmüller signal isolators and terminal blocks installed within the same control cabinet, ensuring that analog signals from field transmitters reach the PROFIBUS I/O stations with full galvanic isolation. For applications requiring network redundancy, a secondary BM-DP12 module can be configured in a redundant master topology, with automatic switchover managed at the CPU level — a design pattern common in power generation and water treatment facilities where unplanned downtime carries significant operational cost.

Industrial Ethernet switches (such as the Hirschmann RS20 or Scalance X series) are typically deployed in the same cabinet to manage the supervisory PROFINET or Modbus TCP layer, while the BM-DP12 maintains the dedicated PROFIBUS DP segment for field devices — a dual-network architecture that separates real-time control traffic from IT-level data collection and SCADA integration.

Discrete Manufacturing & Assembly Lines: In automotive body-in-white or electronics assembly environments, the BM-DP12 manages PROFIBUS DP communication between the IndraControl CPU and distributed I/O stations mounted at each workstation. Cyclic data exchange ensures that conveyor interlocks, pneumatic valve commands, and sensor feedback are processed within the PLC scan cycle, supporting line speeds that demand sub-10 ms response times. The module's auto-baud detection simplifies commissioning when integrating legacy PROFIBUS devices from multiple vendors.

Power Generation & Electrical Substations: In turbine control and substation automation applications, the BM-DP12 provides the PROFIBUS DP link between the IndraControl master and protection relays, energy meters, and switchgear controllers. Its DP-V1 acyclic communication capability allows SCADA systems to read and write device parameters without interrupting the cyclic control loop — a critical requirement for IEC 61850-adjacent architectures where configuration changes must not affect real-time protection functions.

Petrochemical & Process Industries: In continuous process plants handling hazardous materials, the BM-DP12 connects the control layer to PROFIBUS PA field instruments (via DP/PA couplers), including pressure transmitters, flow meters, and positioners. The module's support for up to 125 slave nodes per segment allows a single BM-DP12 to manage an entire process unit's instrumentation loop, reducing the number of communication cards required and simplifying the overall control cabinet layout.

Water Treatment & Municipal Infrastructure: Pump station and water treatment plant automation systems benefit from the BM-DP12's long-distance PROFIBUS DP capability (up to 1,200 m at 93.75 kbps), enabling remote I/O stations to be distributed across large facility footprints without repeaters. Combined with the IndraControl platform's redundancy features, this configuration supports the high-availability requirements typical of critical infrastructure applications.

Mining & Metallurgy: In ore processing and smelting environments, the BM-DP12 operates reliably in high-vibration, high-EMI conditions when installed in properly shielded control cabinets. Its integration with IndraDrive systems enables coordinated control of conveyor drives, crusher motors, and cooling system actuators from a single IndraControl CPU, with PROFIBUS DP providing the real-time communication backbone across the entire drive network.

Q1: Is the BM-DP12 1070075887-304 compatible with all IndraControl L-Series CPUs, and can it coexist with other communication modules on the same backplane?The BM-DP12 is designed for the IndraControl modular backplane system and is compatible with IndraControl L25, L45, and L65 CPU modules. Multiple communication modules — including additional BM-DP12 cards, Ethernet interface modules, and serial communication cards — can be installed on the same backplane, subject to the slot capacity and power budget of the specific IndraControl chassis. Each module is addressed independently via the internal system bus, and the IndraControl engineering software (IndraWorks) provides a unified configuration environment for all installed modules. For multi-protocol architectures requiring simultaneous PROFIBUS DP and PROFINET connectivity, the BM-DP12 can operate in parallel with an Ethernet communication module without mutual interference.

Q2: What commissioning steps are required to integrate the BM-DP12 into an existing PROFIBUS DP network, and how are slave devices configured?Commissioning the BM-DP12 involves importing the GSD (General Station Description) file for each PROFIBUS DP slave device into IndraWorks, assigning station addresses (0–125), and configuring the cyclic I/O data mapping between the PROFIBUS process image and the IndraControl CPU's task variables. The BM-DP12 supports auto-baud detection, so the communication speed is automatically matched to the existing network segment — eliminating manual baud rate configuration during integration into brownfield installations. For DP-V1 devices requiring acyclic parameter access, the IndraWorks function block library provides standardized read/write function blocks that can be called from the PLC application program. NANKMOS supplies the BM-DP12 with a pre-shipment functional test report, and our technical team can provide GSD file sourcing and configuration guidance as part of the 12-Month Warranty support package.

Q3: What does the 12-Month Warranty cover, and what is the typical lead time and stock availability for the BM-DP12 1070075887-304?NANKMOS provides a 12-Month Warranty on the BM-DP12 1070075887-304 covering manufacturing defects, functional failures under normal operating conditions, and firmware-related communication faults identified during the warranty period. Each unit undergoes a pre-shipment functional test — including PROFIBUS DP communication verification, backplane interface check, and visual inspection — before dispatch. Replacement or repair is arranged within the warranty period at no additional cost to the customer. Regarding availability: NANKMOS maintains stock of the BM-DP12 and related IndraControl communication modules to support urgent project timelines. Standard lead time is 3–7 business days for in-stock units, with expedited shipping available for critical maintenance requirements. For volume procurement or long-term supply agreements, please contact [email protected] or call +86 18359268345 to discuss scheduling and pricing.

Quality & Delivery Assurance

Functional InspectionFunctional Inspection

100% tested on professional platforms to ensure stable performance.

Anti-static PackagingAnti-static Packaging

Modules are packed in anti-static bags to prevent electrostatic damage.

Secure Export PackingSecure Export Packing

Cushion protection and strong cartons ensure safe transportation.

Worldwide ShippingWorldwide Shipping

Global logistics network supports air, sea and express delivery.

Documentation CheckDocumentation Check

Part number, revision and compatibility verified before shipment.

After-sales SupportAfter-sales Support

Professional technical support to help resolve your issues.

Related Models Often Requested

View More Related Models