Functional Inspection100% tested on professional platforms to ensure stable performance.
Phoenix Contact PSR-SCP-24DC/ESP4/2X1/1X2 2981020 is a NANKMOS industrial automation product record Listed under Other series series and Business & Industrial > Automation, Control & Flow Devices. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.
Brand names are used for identification only.
Phoenix Contact PSR-SCP-24DC/ESP4/2X1/1X2 2981020 is a NANKMOS industrial automation product record Listed under Other series series and Business & Industrial > Automation, Control & Flow Devices. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.
| Manufacturer | Phoenix Contact |
|---|---|
| Application | Industrial Automation Maintenance |
| Part Number / Model | PSR-SCP-24DC/ESP4/2X1/1X2 2981020 |
| Compatible System | Confirmed by inquiry |
| Condition Options | To Confirm |
| Module Type | Automation, Control & Flow Devices |
| Warranty | 12 Months |
| Packaging | Anti-static Bag / Secure Box |
| Shipping Methods | DHL / FedEx / UPS / Air / Sea |
| Availability | To Confirm |
| Lead Time | To Confirm |
| Documentation | Part number and revision checked before quote |
The Phoenix Contact PSR-SCP-24DC/ESP4/2X1/1X2 (Part No. 2981020) is a compact, high-reliability safety relay engineered for integration into modern industrial communication architectures. Designed to operate at 24 V DC with dual-channel emergency stop and safety door monitoring capability, this relay serves as a critical node in the safety data chain — bridging field-level devices with supervisory control systems across smart factory environments. Whether deployed in discrete manufacturing, process automation, or energy infrastructure, the PSR-SCP-24DC/ESP4/2X1/1X2 delivers deterministic response times and robust signal integrity that modern IIoT-connected plants demand.
In a connected factory, safety is not an isolated function — it is a live data stream. The PSR-SCP-24DC/ESP4/2X1/1X2 integrates seamlessly into safety-rated control architectures where real-time status feedback, remote diagnostics, and alarm traceability are non-negotiable. Its output relay contacts and enable circuit design make it compatible with Phoenix Contact's broader PSR safety relay family, including the PSR-MC22 modular safety controller and PSR-TRISAFE configurable safety systems, enabling scalable safety logic without rewiring.
In a fully networked automation site, the PSR-SCP-24DC/ESP4/2X1/1X2 occupies a foundational role in the safety signal chain. At the field level, emergency stop buttons, light curtains, and safety door switches feed dual-channel signals directly into the relay's monitored input circuit. The relay's enable contacts then control downstream actuators — motor starters, servo drives, or pneumatic valves — while simultaneously providing a feedback signal to the safety I/O layer.
This feedback signal is captured by a Phoenix Contact AXL F BK PN (PROFINET bus coupler) or a Axioline F safety I/O module, which transmits real-time safety status over PROFINET to a Siemens S7-1500F or Allen-Bradley GuardLogix safety PLC. The PLC processes the safety state and forwards structured data packets upstream via an industrial Ethernet backbone — typically managed through a Phoenix Contact FL SWITCH 2000 series managed industrial Ethernet switch — ensuring deterministic, low-latency data delivery across the plant network.
At the supervisory layer, a Phoenix Contact TC ROUTER 3002T or compatible industrial router aggregates safety event data and forwards it to the SCADA platform — such as Wonderware, Ignition, or Siemens WinCC — where operators monitor safety relay states, acknowledge alarms, and track trip histories in real time. HMI panels connected via Ethernet display live relay status, enabling operators on the floor to identify fault conditions without leaving the workstation.
For sites requiring remote diagnostics, a Phoenix Contact mGuard RS4000 industrial security router or an FL mGuard VPN gateway enables encrypted remote access to the safety network. Maintenance engineers can remotely inspect relay status, review alarm logs, and validate safety circuit continuity — reducing unplanned downtime and eliminating the need for on-site intervention for routine diagnostics.
Power integrity across the safety circuit is maintained by a Phoenix Contact QUINT POWER 24 V DC power supply with SFB (Selective Fuse Breaking) technology, ensuring that a short circuit in one branch does not cascade into adjacent safety circuits. This power architecture, combined with the PSR-SCP-24DC/ESP4/2X1/1X2's self-monitoring relay design, creates a resilient, fault-tolerant safety data link from sensor to cloud.
Protocol Fragmentation: Many legacy plants operate with a mix of hardwired safety circuits, PROFIBUS DP networks, and newer PROFINET or EtherNet/IP backbones. The PSR-SCP-24DC/ESP4/2X1/1X2, when paired with Phoenix Contact's GW PB DP/MODBUS TCP protocol gateway, bridges hardwired safety status into Modbus TCP or PROFIBUS data frames — eliminating protocol islands and enabling unified SCADA visibility across mixed-generation equipment.
Data Silos and Production Transparency: Safety relay trip events are often siloed in local control panels, invisible to plant-level MES or ERP systems. By routing PSR-SCP status signals through the Axioline F I/O bus and PROFINET backbone, trip events become structured data records — timestamped, tagged by zone, and available for OEE analysis, shift reporting, and predictive maintenance workflows.
Remote Monitoring and Alarm Traceability: Without network-connected safety diagnostics, alarm root-cause analysis requires physical inspection. The PSR-SCP-24DC/ESP4/2X1/1X2's feedback circuit, integrated with SCADA alarm management, enables automatic alarm logging with relay ID, trip time, and reset confirmation — supporting IEC 62682-compliant alarm rationalization and audit trail requirements.
System Scalability: As production lines expand, safety architectures must scale without full redesign. The PSR-SCP-24DC/ESP4/2X1/1X2's DIN rail form factor and compatibility with the PSR modular safety relay family allow zone-by-zone expansion — adding new emergency stop loops or safety door circuits without disrupting existing network topology or PLC safety program structure.
Q1: Can the PSR-SCP-24DC/ESP4/2X1/1X2 2981020 be integrated into a PROFINET or EtherNet/IP network for real-time safety status monitoring? The PSR-SCP-24DC/ESP4/2X1/1X2 uses hardwired dual-channel safety inputs and relay outputs. Its enable and signaling contacts can be wired to Phoenix Contact Axioline F or Inline safety I/O modules, which communicate over PROFINET or EtherNet/IP to the safety PLC. This allows real-time safety state data — including relay energized/de-energized status and feedback loop integrity — to be visible in SCADA and HMI systems with cycle-time resolution.
Q2: What is the communication latency for safety trip detection and upstream SCADA alarm generation? The PSR-SCP-24DC/ESP4/2X1/1X2 achieves response times compliant with EN ISO 13849-1 Category 4 / PLe requirements. Hardwired trip detection is sub-20 ms at the relay level. Upstream SCADA alarm propagation depends on the PROFINET cycle time (typically 1–10 ms) and SCADA polling interval, with end-to-end alarm visibility achievable within 100–500 ms in well-configured networks — well within IEC 62682 alarm response benchmarks.
Q3: How does the PSR-SCP-24DC/ESP4/2X1/1X2 support remote diagnostics and predictive maintenance in a smart factory? By integrating the relay's feedback contacts into the plant's safety I/O bus and forwarding status data via PROFINET to the SCADA layer, maintenance teams can monitor relay health remotely through VPN-secured access (e.g., via Phoenix Contact mGuard routers). Trip frequency analysis, contact wear trending, and alarm pattern recognition can be performed without physical access — enabling condition-based maintenance scheduling and reducing unplanned downtime.
Q4: What warranty and pre-shipment testing does the PSR-SCP-24DC/ESP4/2X1/1X2 2981020 carry? Every PSR-SCP-24DC/ESP4/2X1/1X2 2981020 unit supplied by NANKMOS is covered by a 12-Month Warranty and undergoes pre-shipment functional verification — including input channel monitoring, output relay actuation, and feedback loop continuity checks — before dispatch. Stock is maintained for immediate availability, with rapid fulfillment to support both project timelines and emergency replacement requirements.
Functional Inspection100% tested on professional platforms to ensure stable performance.
Anti-static PackagingModules are packed in anti-static bags to prevent electrostatic damage.
Secure Export PackingCushion protection and strong cartons ensure safe transportation.
Worldwide ShippingGlobal logistics network supports air, sea and express delivery.
Documentation CheckPart number, revision and compatibility verified before shipment.
After-sales SupportProfessional technical support to help resolve your issues.