Global Industrial Automation Sourcing

EN  /  CN
NANKMOSEmpower Industry. Advance Future.
Send Inquiry

Siemens 6AV2124-0JC01-0AX0 HMI Touch Panel

Siemens 6AV2124-0JC01-0AX0 is a NANKMOS industrial automation product record Listed under SIMATIC series and HMI Panels. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.

Brand names are used for identification only.
Product Snapshot

Availability & Sourcing Details

Siemens 6AV2124-0JC01-0AX0 is a NANKMOS industrial automation product record Listed under SIMATIC series and HMI Panels. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.

Automation Part Control System SIMATIC Siemens
Application
Industrial Automation Maintenance
Condition Options
New / Used / Refurbished
Availability
Confirmed by Email
Warranty
12 Months
Packaging
Anti-static Bag / Secure Box
Shipping
DHL / FedEx / UPS / Air / Sea

Product Information

ManufacturerSiemens
ApplicationIndustrial Automation Maintenance
Part Number / Model6AV2124-0JC01-0AX0
Compatible SystemSIMATIC
SeriesSIMATIC
Condition OptionsTo Confirm
Module TypeHMI Panels
Warranty12 Months
PackagingAnti-static Bag / Secure Box
Shipping MethodsDHL / FedEx / UPS / Air / Sea
AvailabilityTo Confirm
Lead TimeTo Confirm
DocumentationPart number and revision checked before quote
Product Details

6AV2124-0JC01-0AX0 Product Description

The Siemens 6AV2124-0JC01-0AX0 TP900 Comfort Panel is a 9-inch widescreen touch HMI engineered for high-density industrial data environments. Designed to serve as the primary visualization and control node in smart factory architectures, this panel bridges field-level devices — sensors, actuators, and remote I/O modules — with upper-level SCADA platforms, MES systems, and cloud-based analytics engines. Its native PROFINET interface, combined with MPI/PROFIBUS DP support, makes it a versatile gateway across heterogeneous automation networks, enabling seamless protocol convergence without additional conversion hardware.

In modern smart manufacturing, the ability to visualize, interact with, and respond to real-time process data is not optional — it is the operational backbone. The 6AV2124-0JC01-0AX0 delivers exactly this capability: a high-resolution 800×480 display with multi-touch input, paired with a robust communication stack that supports simultaneous connections to Siemens S7-1200, S7-1500, and S7-300/400 PLC families. Whether deployed on a discrete assembly line, a continuous process plant, or a hybrid smart factory cell, this panel provides the operator interface layer that transforms raw automation signals into actionable production intelligence.

The 6AV2124-0JC01-0AX0 sits at the intersection of field instrumentation and supervisory control, functioning as the real-time data aggregation and visualization node in a layered smart factory network. At the field level, process signals originate from distributed sensors — pressure transmitters, flow meters, temperature probes, and proximity switches — connected to remote I/O modules such as the Siemens ET 200SP or ET 200MP. These I/O stations communicate upstream via PROFINET, delivering structured process data to the S7-1500 PLC controller, which executes the core automation logic.

The 6AV2124-0JC01-0AX0 connects directly to the S7-1500 over PROFINET RT, rendering live process variables, alarm states, and production KPIs on its 9-inch multi-touch display. Operators can interact with the panel to issue setpoint changes, acknowledge alarms, and navigate between production screens — all without leaving the machine cell. For legacy equipment still running on PROFIBUS DP or MPI networks — such as older S7-300 controllers or third-party variable frequency drives (VFDs) — the panel's RS-422/485 port provides a direct communication path, eliminating the need for a standalone PROFIBUS-to-PROFINET gateway module.

At the network layer, the panel integrates into the plant's industrial Ethernet backbone via managed industrial switches — for example, Siemens SCALANCE X208 or X308-2M — which enforce VLAN segmentation, PROFINET Media Redundancy Protocol (MRP) ring topology, and Quality of Service (QoS) prioritization for time-critical IRT traffic. This ensures that HMI polling cycles remain deterministic even under high network load from concurrent SCADA polling, historian writes, and OPC UA data publishing.

Upstream, the SCADA layer — typically WinCC Runtime Professional or a third-party platform such as Ignition SCADA — connects to the same PROFINET segment, subscribing to process tags published by the S7-1500. The 6AV2124-0JC01-0AX0 complements this architecture by providing localized operator control at the machine level, while the SCADA system aggregates data plant-wide for trend analysis, batch reporting, and regulatory compliance logging. Edge gateway devices — such as the Siemens SINEMA Remote Connect or an IIoT-capable edge computing module — can further extend this data chain to cloud analytics platforms, enabling predictive maintenance models and OEE dashboards fed by the same real-time data stream that the panel visualizes locally.

For drive integration, the panel communicates with Siemens SINAMICS G120 or S120 variable frequency drives via PROFINET, enabling direct speed reference commands, fault acknowledgment, and energy consumption monitoring from the HMI screen. This eliminates the need for separate drive operator panels on each VFD, reducing cabinet complexity and centralizing drive diagnostics within the plant's unified HMI/SCADA architecture. Power supply integrity for the panel and associated field devices is maintained by Siemens SITOP PSU8600 modular power supplies, which provide 24 V DC with diagnostic output signaling — feeding status data back into the PROFINET network for centralized power health monitoring.

Industrial sites operating with mixed-generation equipment frequently encounter data fragmentation: legacy PROFIBUS DP devices cannot natively communicate with modern PROFINET controllers, creating protocol islands that prevent unified monitoring. The 6AV2124-0JC01-0AX0 addresses this directly through its dual-protocol architecture — PROFINET on the Ethernet side and MPI/PROFIBUS DP on the serial side — acting as a transparent bridge that unifies data from both network generations into a single operator view.

Remote monitoring gaps are equally common. Without a network-connected HMI at the machine level, maintenance engineers must physically visit each cell to diagnose faults. The 6AV2124-0JC01-0AX0, integrated with Siemens SINEMA Remote Connect, enables secure remote desktop access to the panel over VPN, allowing engineers to view live process screens, acknowledge alarms, and perform parameter adjustments from any location — reducing mean time to repair (MTTR) and eliminating unnecessary site visits.

Production line transparency is achieved through the panel's alarm management system, which logs fault events with timestamps, operator acknowledgments, and duration data. This alarm history feeds into WinCC's reporting engine, providing shift supervisors with structured downtime analysis and enabling root-cause investigations without relying on manual logbooks. For sites scaling toward Industry 4.0, the panel's OPC UA server capability (via the connected S7-1500) allows third-party MES and ERP systems to subscribe to production data in real time, closing the loop between shop-floor execution and enterprise planning without custom middleware development.

Q1: What is the communication latency between the 6AV2124-0JC01-0AX0 and a connected S7-1500 PLC over PROFINET? With PROFINET RT (Real-Time) configured, typical cycle times are 1–4 ms, sufficient for most HMI visualization and operator control applications. For motion-critical applications requiring sub-millisecond synchronization, PROFINET IRT (Isochronous Real-Time) can be configured on compatible SCALANCE switches, achieving cycle times down to 250 µs.

Q2: Can the 6AV2124-0JC01-0AX0 communicate simultaneously with both PROFINET and PROFIBUS DP devices? Yes. The panel supports concurrent communication via its PROFINET RJ45 ports and its RS-422/485 MPI/PROFIBUS DP interface. This allows it to display data from both modern S7-1500 controllers on PROFINET and legacy S7-300 or third-party PROFIBUS DP devices on the same operator screen, without requiring a separate gateway module.

Q3: How is network stability maintained in ring topology deployments? The 6AV2124-0JC01-0AX0 supports PROFINET Media Redundancy Protocol (MRP) when deployed with MRP-capable managed switches such as the Siemens SCALANCE X308-2M. In the event of a single cable or switch port failure, MRP reconfigures the ring within 200 ms, maintaining continuous HMI communication and preventing operator screen blackouts during network faults.

Q4: What warranty and pre-shipment testing does NANKMOS provide for the 6AV2124-0JC01-0AX0? Every unit ships with a 12-Month Warranty covering hardware defects and communication interface failures. Prior to dispatch, each panel undergoes functional power-on testing, PROFINET port verification, and display integrity checks. Units are sourced from authorized distribution channels and stored in ESD-safe, climate-controlled inventory. In-stock units are available for same-week dispatch with full traceability documentation.

Quality & Delivery Assurance

Functional InspectionFunctional Inspection

100% tested on professional platforms to ensure stable performance.

Anti-static PackagingAnti-static Packaging

Modules are packed in anti-static bags to prevent electrostatic damage.

Secure Export PackingSecure Export Packing

Cushion protection and strong cartons ensure safe transportation.

Worldwide ShippingWorldwide Shipping

Global logistics network supports air, sea and express delivery.

Documentation CheckDocumentation Check

Part number, revision and compatibility verified before shipment.

After-sales SupportAfter-sales Support

Professional technical support to help resolve your issues.

Related Models Often Requested