Siemens 6RY1703-1HD02 C98043-A7021-L1-3 Communication Module

Siemens 6RY1703-1HD02 C98043-A7021-L1-3 is a NANKMOS industrial automation product record Listed under SIMOREG series and Drives. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.

Brand names are used for identification only.
Product Snapshot

Availability & Sourcing Details

Siemens 6RY1703-1HD02 C98043-A7021-L1-3 is a NANKMOS industrial automation product record Listed under SIMOREG series and Drives. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.

Network Module Drive System SIMOREG Siemens
Application
Industrial Network Communication
Condition Options
New / Used / Refurbished
Availability
Confirmed by Email
Warranty
12 Months
Packaging
Anti-static Bag / Secure Box
Shipping
DHL / FedEx / UPS / Air / Sea

Product Information

ManufacturerSiemens
ApplicationIndustrial Network Communication
Part Number / Model6RY1703-1HD02 C98043-A7021-L1-3
Compatible SystemSIMOREG
SeriesSIMOREG
Condition OptionsTo Confirm
Module TypeCommunication Module
Warranty12 Months
PackagingAnti-static Bag / Secure Box
Shipping MethodsDHL / FedEx / UPS / Air / Sea
AvailabilityTo Confirm
Lead TimeTo Confirm
DocumentationPart number and revision checked before quote
Product Details

6RY1703-1HD02 C98043-A7021-L1-3 Product Description

The Siemens 6RY1703-1HD02 is a dedicated PROFIBUS-DP communication interface board engineered for the SIMOREG DC Master series of digital DC drive converters. Designed to bridge the gap between high-power DC drive systems and plant-level automation networks, this module enables seamless, real-time data exchange across the full industrial data chain — from field-level signal acquisition through PLC control, SCADA supervision, and enterprise-level data visualisation. In smart factory environments where production transparency, remote diagnostics, and deterministic network performance are non-negotiable, the 6RY1703-1HD02 delivers the protocol backbone that keeps DC drive assets fully visible and controllable.

Installed directly into the SIMOREG DC Master converter's option slot, the 6RY1703-1HD02 exposes the drive's complete parameter set, status words, control words, actual values, and fault registers to the PROFIBUS-DP master — typically a Siemens SIMATIC S7-300 or S7-400 PLC acting as the DP master controller. This tight integration eliminates the need for analogue setpoint wiring and discrete I/O handshaking, replacing them with a single, noise-immune, 12 Mbit/s digital bus connection. The result is faster control loop response, richer diagnostic data, and a dramatically simplified cabinet layout.

Understanding the 6RY1703-1HD02's role requires tracing the complete data flow from the physical process through to the control room. At the field level, current and voltage transducers mounted on the DC motor armature and field circuits feed analogue signals into the SIMOREG DC Master's internal measurement boards. The drive's closed-loop speed and current regulators process these signals in real time, generating armature voltage commands that are executed by the thyristor power stack. With the 6RY1703-1HD02 installed, every one of these internal values — actual speed, armature current, field current, DC bus voltage, drive status word, fault code — is simultaneously packaged into PROFIBUS-DP process data objects (PDOs) and transmitted cyclically to the DP master at the configured baud rate.

The SIMATIC S7-400 PLC acting as PROFIBUS DP master receives this data within each PLC scan cycle, typically under 10 ms at 1.5 Mbit/s, enabling the PLC program to implement supervisory speed references, coordinated multi-drive sequencing, and interlocking logic without any analogue I/O latency. For multi-drive paper machine or rolling mill applications, where several SIMOREG DC Master converters must be synchronised in speed or torque, the PROFIBUS network — managed through the 6RY1703-1HD02 on each drive — provides the deterministic timing backbone that analogue systems cannot match.

Moving up the automation pyramid, the S7 PLC communicates with the plant SCADA layer via Industrial Ethernet. A Siemens SCALANCE X208 managed industrial switch aggregates the Ethernet segments from multiple S7 controllers and routes data to the SCADA server running Siemens WinCC. Operators at the HMI workstation — often a Siemens TP1500 Comfort Panel — can view real-time drive speed trends, armature current curves, and fault history logs sourced directly from the SIMOREG DC Master via the PROFIBUS data chain. Alarm thresholds configured in WinCC trigger pop-up notifications when drive parameters exceed defined limits, enabling rapid operator response before process quality is affected.

For remote diagnostics and predictive maintenance, the SCADA data is forwarded through an industrial edge gateway — such as a Siemens SINEMA Remote Connect-enabled router — to cloud-based analytics platforms. Maintenance engineers can remotely interrogate the SIMOREG DC Master's parameter set, review historical fault logs, and even initiate controlled parameter changes through the PROFIBUS acyclic services (DP V1) supported by the 6RY1703-1HD02, all without physical access to the switchgear room. This capability is particularly valuable for remote mining, offshore, or multi-site manufacturing operations where on-site service visits are costly.

The data chain also extends downward to auxiliary field devices. A Siemens ET 200S distributed I/O station on the same PROFIBUS segment can collect digital status signals from motor protection relays, cooling fan contactors, and field excitation units, feeding these into the same PLC program that manages the SIMOREG DC Master. Similarly, a SIRIUS 3RW44 soft starter or auxiliary MICROMASTER 440 AC drive on a secondary PROFIBUS segment can be coordinated with the DC drive system through the PLC, enabling mixed AC/DC drive architectures within a single unified network. The 6RY1703-1HD02 is the critical link that brings the SIMOREG DC Master into this unified data ecosystem.

Protocol fragmentation is one of the most persistent challenges in brownfield industrial sites. Older DC drive installations often rely on proprietary serial interfaces or analogue speed references that cannot be read by modern PROFIBUS or Profinet-based PLC systems. The 6RY1703-1HD02 resolves this by providing a standards-compliant PROFIBUS-DP interface that any DP master can address using standard GSD file configuration, eliminating the need for custom protocol converters or legacy communication adapters.

Data islands — where drive data exists only within the drive itself and is inaccessible to the plant control system — are eliminated once the 6RY1703-1HD02 is installed. All SIMOREG DC Master parameters become readable and writable from the PLC and SCADA layers, enabling centralised parameter management, remote commissioning, and automated fault logging. Production engineers gain full visibility into drive operating hours, energy consumption, and thermal loading without requiring local keypad access.

Remote monitoring gaps are addressed through the PROFIBUS acyclic channel (DP V1), which allows the SCADA system to read any of the SIMOREG DC Master's 900+ parameters on demand, not just the cyclic process data. This means that predictive maintenance algorithms running in WinCC or a third-party MES can poll drive health indicators — motor temperature, thyristor junction temperature estimates, cooling airflow status — and generate maintenance work orders automatically before failures occur.

Production line transparency is enhanced by integrating the 6RY1703-1HD02 data stream into OEE (Overall Equipment Effectiveness) dashboards. By correlating drive speed actual values with upstream and downstream process sensors — tension transducers, thickness gauges, flow meters — plant managers can identify speed-related quality deviations in real time and trace them back to specific drive events logged in the PROFIBUS data record.

System expansion is straightforward: the PROFIBUS-DP network supports up to 126 node addresses, so additional SIMOREG DC Master drives, ET 200 I/O stations, or other PROFIBUS-capable devices can be added to the network without architectural changes, provided the total cable length and segment loading remain within specification. The 6RY1703-1HD02's auto-baud detection ensures that new drives integrate into the existing network at the correct transmission rate without manual configuration.

Q1: What is the maximum PROFIBUS-DP baud rate supported by the 6RY1703-1HD02, and does it affect control loop performance? The 6RY1703-1HD02 supports PROFIBUS-DP baud rates from 9.6 kbit/s up to 12 Mbit/s with automatic baud rate detection. At 1.5 Mbit/s — the most common industrial setting — cyclic data exchange completes within a single PLC scan cycle (typically 5–10 ms), which is fast enough for supervisory speed reference updates and status monitoring. The SIMOREG DC Master's internal current and speed regulators operate independently of the PROFIBUS cycle, so network latency does not degrade closed-loop drive performance.

Q2: Is the 6RY1703-1HD02 compatible with third-party PROFIBUS DP masters, or only Siemens SIMATIC PLCs? The 6RY1703-1HD02 is fully compliant with the PROFIBUS-DP standard (EN 50170 / IEC 61158) and ships with a standard GSD (General Station Description) file. It is compatible with any certified PROFIBUS-DP V0/V1 master, including controllers from Rockwell Automation, Schneider Electric, ABB, Beckhoff, and other vendors. Configuration is performed by importing the GSD file into the master's engineering tool and assigning the drive's PROFIBUS node address via the SIMOREG DC Master's parameter settings.

Q3: How does the 6RY1703-1HD02 support remote diagnostics and fault tracing without on-site access? Using PROFIBUS DP V1 acyclic services, the SCADA or maintenance system can read the SIMOREG DC Master's complete fault buffer, alarm history, and operating hour counters on demand. Combined with a remote access solution such as Siemens SINEMA Remote Connect, maintenance engineers can retrieve fault codes, review parameter snapshots taken at the moment of a trip, and perform guided parameter adjustments remotely. This capability significantly reduces mean time to repair (MTTR) for remote or unmanned installations.

Q4: What warranty and pre-shipment testing does the 6RY1703-1HD02 come with? Every 6RY1703-1HD02 unit supplied by NANKMOS carries a 12-month warranty covering manufacturing defects and functional failures under normal operating conditions. Each unit undergoes functional communication testing prior to shipment to verify PROFIBUS-DP initialisation, cyclic data exchange, and parameter access. Units are held in-stock and available for immediate dispatch, with lead times confirmed at the time of order. For volume procurement or project-specific requirements, contact NANKMOS at [email protected] or +86 18359268345.

Quality & Delivery Assurance

Functional InspectionFunctional Inspection

100% tested on professional platforms to ensure stable performance.

Anti-static PackagingAnti-static Packaging

Modules are packed in anti-static bags to prevent electrostatic damage.

Secure Export PackingSecure Export Packing

Cushion protection and strong cartons ensure safe transportation.

Worldwide ShippingWorldwide Shipping

Global logistics network supports air, sea and express delivery.

Documentation CheckDocumentation Check

Part number, revision and compatibility verified before shipment.

After-sales SupportAfter-sales Support

Professional technical support to help resolve your issues.

Related Models Often Requested

View More Related Models