Global Industrial Automation Sourcing

EN  /  CN
NANKMOSEmpower Industry. Advance Future.
Send Inquiry

Siemens 6XU1830-0EH10 6XV1830-0EH10 PROFIBUS Cable

Siemens 6XU1830-0EH10 6XV1830-0EH10 is a NANKMOS industrial automation product record Listed under Other series series and Cables & Connectors. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.

Brand names are used for identification only.
Product Snapshot

Availability & Sourcing Details

Siemens 6XU1830-0EH10 6XV1830-0EH10 is a NANKMOS industrial automation product record Listed under Other series series and Cables & Connectors. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.

Network Interface Control System Siemens
Application
Industrial Network & Bus Termination
Condition Options
New / Used / Refurbished
Availability
Confirmed by Email
Warranty
12 Months
Packaging
Anti-static Bag / Secure Box
Shipping
DHL / FedEx / UPS / Air / Sea

Product Information

ManufacturerSiemens
ApplicationIndustrial Network & Bus Termination
Part Number / Model6XU1830-0EH10 6XV1830-0EH10
Compatible SystemConfirmed by inquiry
Condition OptionsTo Confirm
Module TypeBus / Network Interface Module
Warranty12 Months
PackagingAnti-static Bag / Secure Box
Shipping MethodsDHL / FedEx / UPS / Air / Sea
AvailabilityTo Confirm
Lead TimeTo Confirm
DocumentationPart number and revision checked before quote
Product Details

6XU1830-0EH10 6XV1830-0EH10 Product Description

The Siemens 6XV1830-0EH10 is a standard PROFIBUS bus cable engineered for seamless integration into SIMATIC-based distributed control architectures. Designed to meet the IEC 61158 PROFIBUS specification, this cable serves as the physical communication backbone connecting programmable logic controllers, remote I/O stations, field devices, and intelligent drive systems across multi-node industrial networks. Its violet-sheathed, shielded twisted-pair construction ensures reliable signal transmission at baud rates up to 12 Mbit/s, making it the preferred choice for high-speed, noise-immune fieldbus deployments in demanding industrial environments.

In a layered control architecture, the 6XV1830-0EH10 operates at the field communication layer — the critical link between the control layer and the I/O and execution layers. Its role is not merely passive cable routing; it defines the signal integrity, topology flexibility, and long-term maintainability of the entire PROFIBUS segment. Whether deployed in a linear bus, tree, or star topology using RS-485 repeaters, this cable supports the structural consistency that modern automation platforms demand.

The 6XV1830-0EH10 achieves its full value when considered within the broader SIMATIC automation platform. At the control layer, a Siemens S7-400 CPU 414-3 PN/DP or S7-300 CPU 315-2 DP acts as the PROFIBUS DP master, coordinating cyclic data exchange with all connected slave devices. The cable physically links this master to distributed I/O stations such as the Siemens ET 200M or ET 200S, which host analog and digital I/O modules for process signal acquisition and actuation command delivery.

At the drive and execution layer, the 6XV1830-0EH10 connects the PLC master to Siemens SINAMICS G120 or MICROMASTER 440 variable frequency drives via PROFIBUS DP, enabling parameter read/write, speed reference transmission, and fault diagnostics — all over a single cable pair. This eliminates the need for separate analog setpoint wiring and reduces cabinet complexity significantly.

For network segmentation and long-distance runs, Siemens SIMATIC NET RS-485 Repeater 6ES7972-0AA02-0XA0 units extend segment length and electrically isolate bus sections, preserving signal quality across large plant footprints. Bus termination is handled by PROFIBUS connectors such as the 6ES7972-0BB52-0XA0 (with integrated terminating resistors), which must be correctly installed at both ends of each cable segment to prevent signal reflection and ensure stable communication at high baud rates.

At the HMI layer, Siemens SIMATIC TP1200 Comfort or KTP700 Basic panels connect to the PROFIBUS network either directly or via MPI/PROFIBUS adapters, providing operators with real-time process visualization and alarm management. The physical reliability of the 6XV1830-0EH10 directly supports HMI data refresh rates and alarm response latency — critical in process-intensive applications.

For redundant architectures, the cable supports dual-ring or dual-bus topologies when used with Siemens SCALANCE X204-2 managed switches (for PROFINET migration paths) or dedicated PROFIBUS redundancy couplers. In safety-instrumented systems, the cable integrates with Siemens S7-300F / S7-400F fail-safe CPUs and PROFIsafe-enabled I/O modules, maintaining the deterministic communication required for SIL 2/3 safety loops.

Power supply stability for the entire distributed architecture is ensured by Siemens SITOP PSU100S 24V/10A or SITOP UPS1600 uninterruptible power supplies, which protect against voltage transients that could otherwise corrupt PROFIBUS frame transmission. Together, these components form a cohesive, validated automation platform where the 6XV1830-0EH10 serves as the connective tissue binding every layer into a unified, high-performance control system.

Manufacturing & Discrete Automation: In automotive body-in-white lines and general assembly systems, the 6XV1830-0EH10 interconnects SIMATIC S7 PLCs with robot controllers, servo drives, and vision system gateways over PROFIBUS DP. Its robust shielding handles the high electromagnetic interference generated by welding equipment and servo amplifiers, maintaining deterministic cycle times essential for synchronized multi-axis motion.

Power Generation & Utilities: In thermal power plants and substation automation, PROFIBUS DP networks built on 6XV1830-0EH10 cable connect turbine control systems, excitation regulators, and protection relay panels to the DCS supervisory layer. The cable's low capacitance and precise impedance matching ensure that protection relay trip signals and analog measurement data are transmitted without distortion across long cable runs in high-voltage environments.

Petrochemical & Refinery Process Control: In continuous process plants, the cable links SIMATIC S7-400 process controllers to PROFIBUS PA field instruments — pressure transmitters, flow meters, and control valve positioners — via DP/PA segment couplers. This architecture enables HART-equivalent diagnostics over PROFIBUS, supporting predictive maintenance programs and reducing unplanned shutdowns.

Water & Wastewater Treatment: Municipal water treatment facilities use PROFIBUS networks cabled with 6XV1830-0EH10 to integrate pump drives, dosing systems, level sensors, and SCADA gateways. The cable's UV-resistant PVC sheath and wide operating temperature range support outdoor and partially exposed installation in pump stations and filtration buildings.

Mining, Metallurgy & Heavy Industry: In ore processing plants and steel mills, the cable connects high-power drive systems, conveyor PLCs, and weighing systems across large distances. Its Type A specification supports the maximum segment lengths needed in sprawling plant layouts, while its shielded construction resists interference from high-current motor drives and induction furnaces.

Q1: Is the 6XV1830-0EH10 compatible with all PROFIBUS DP baud rates, and how does cable length affect baud rate selection? Yes. The 6XV1830-0EH10 is a Type A PROFIBUS cable compliant with EN 50170 / IEC 61158, supporting all standard PROFIBUS DP baud rates from 9.6 kbit/s to 12 Mbit/s. Maximum segment length is inversely related to baud rate: at 9.6–187.5 kbit/s, segments up to 1,200 m are supported; at 1.5 Mbit/s, up to 400 m; at 12 Mbit/s, up to 100 m per segment. For longer runs, Siemens RS-485 repeaters can be inserted to extend total network reach while maintaining signal integrity.

Q2: How should bus termination be handled when integrating 6XV1830-0EH10 into an existing SIMATIC PROFIBUS architecture? Bus termination must be applied at both physical ends of each PROFIBUS segment using resistor networks that match the cable's characteristic impedance (typically 220 Ω pull-up, 390 Ω pull-down configuration per RS-485 standard). Siemens PROFIBUS connectors with integrated switchable termination (e.g., 6ES7972-0BB52-0XA0) simplify this process. Incorrect or missing termination causes signal reflections that manifest as intermittent communication errors, especially at baud rates above 1.5 Mbit/s. Only the two end nodes of each segment should have termination enabled.

Q3: What warranty and supply assurance does NANKMOS provide for the 6XV1830-0EH10, and how is pre-shipment quality verified? NANKMOS provides a 12-Month Warranty on all 6XV1830-0EH10 units covering manufacturing defects and electrical performance. Prior to shipment, each cable reel or cut length undergoes pre-shipment testing including conductor continuity verification, insulation resistance measurement, and shield coverage inspection. Units are sourced from verified supply channels and held in climate-controlled storage to prevent sheath degradation. In-stock units are available for immediate dispatch with full traceability documentation. For project-volume orders or urgent requirements, contact [email protected] or +86 18359268345.

Quality & Delivery Assurance

Functional InspectionFunctional Inspection

100% tested on professional platforms to ensure stable performance.

Anti-static PackagingAnti-static Packaging

Modules are packed in anti-static bags to prevent electrostatic damage.

Secure Export PackingSecure Export Packing

Cushion protection and strong cartons ensure safe transportation.

Worldwide ShippingWorldwide Shipping

Global logistics network supports air, sea and express delivery.

Documentation CheckDocumentation Check

Part number, revision and compatibility verified before shipment.

After-sales SupportAfter-sales Support

Professional technical support to help resolve your issues.

Related Models Often Requested