Functional Inspection100% tested on professional platforms to ensure stable performance.
Allen-Bradley 1426-M5E-DNT is a NANKMOS industrial automation product record Listed under Other series series and Business & Industrial > Automation, Control & Flow Devices. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.
Brand names are used for identification only.
Allen-Bradley 1426-M5E-DNT is a NANKMOS industrial automation product record Listed under Other series series and Business & Industrial > Automation, Control & Flow Devices. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.
| Manufacturer | Allen-Bradley |
|---|---|
| Application | Control System Power Support |
| Part Number / Model | 1426-M5E-DNT |
| Compatible System | Confirmed by inquiry |
| Condition Options | To Confirm |
| Module Type | Power Supply Module |
| Warranty | 12 Months |
| Packaging | Anti-static Bag / Secure Box |
| Shipping Methods | DHL / FedEx / UPS / Air / Sea |
| Availability | To Confirm |
| Lead Time | To Confirm |
| Documentation | Part number and revision checked before quote |
The Allen-Bradley 1426-M5E-DNT is a dual-protocol power monitoring module from the PowerMonitor 5000 series, engineered to bridge energy data from field-level electrical infrastructure into the broader industrial automation network. Supporting both EtherNet/IP and DeviceNet simultaneously, this unit enables seamless data flow from power distribution panels and motor control centers directly into PLC controllers, SCADA platforms, HMI terminals, and enterprise energy management systems — forming a critical node in the smart factory data chain.
In modern manufacturing environments, energy visibility is no longer optional. The 1426-M5E-DNT captures real-time voltage, current, power factor, harmonic distortion, and demand data at the point of consumption, then transmits structured measurement packets across the plant network. Whether integrated with a ControlLogix L83E or CompactLogix L33ER controller via EtherNet/IP, or connected to a legacy DeviceNet trunk alongside PowerFlex 755 drives and 1734 POINT I/O modules, this monitor ensures that energy data is always available where decisions are made.
The 1426-M5E-DNT sits at the intersection of power infrastructure and automation data networks, making it a foundational component in any smart factory energy architecture. At the field level, it monitors incoming power feeds to critical loads — including motor starters, variable frequency drives such as the PowerFlex 523 and PowerFlex 755, and large process equipment. The measured electrical parameters are encoded into CIP (Common Industrial Protocol) data objects and transmitted over EtherNet/IP to the plant's control backbone.
Within a typical ControlLogix rack, the L85E or L83E processor receives cyclic energy data from the 1426-M5E-DNT via Produced/Consumed tags, making real-time power consumption visible in ladder logic and function block programs without additional polling overhead. This same data can be simultaneously consumed by a FactoryTalk View SE SCADA server, where energy dashboards display per-zone consumption trends, peak demand windows, and power quality alarms — all updated in sub-second intervals.
On the DeviceNet side, the 1426-M5E-DNT connects to the same trunk as 1734 POINT I/O adapters, 1756-DNB scanner modules, and legacy SLC 500 controllers, enabling energy data to flow into older automation architectures without requiring network upgrades. This dual-protocol capability is particularly valuable in brownfield facilities where EtherNet/IP and DeviceNet coexist across different production zones.
For remote diagnostics and predictive maintenance, the 1426-M5E-DNT's EtherNet/IP port supports integration with edge gateway devices and IoT data collectors. Platforms such as Rockwell's FactoryTalk Analytics or third-party MQTT brokers can subscribe to energy data streams, enabling cloud-based visualization, anomaly detection, and long-term trend analysis. When power quality events such as voltage sags, current imbalances, or harmonic spikes are detected, the module generates alarm objects that propagate through the network to operator HMI panels and SCADA alarm management systems — ensuring rapid response and minimizing unplanned downtime.
In multi-zone factory layouts, multiple 1426-M5E-DNT units can be deployed across substations and distribution boards, with all data aggregating through managed industrial Ethernet switches into a centralized energy management server. Combined with 1426-M5E (EtherNet/IP only) units in lower-priority zones and 1426-M5 base modules in standalone metering applications, the PowerMonitor 5000 family provides a scalable, network-aware energy monitoring architecture that grows with the facility.
Many industrial facilities face persistent challenges in energy visibility: power meters that cannot communicate with modern SCADA systems, isolated energy data that never reaches the control layer, and no mechanism for remote diagnostics when electrical anomalies occur. The 1426-M5E-DNT directly addresses these gaps.
Its dual-protocol design eliminates the need for protocol converters or intermediate gateways between EtherNet/IP and DeviceNet segments — a common source of latency and data loss in mixed-network environments. By natively speaking both protocols, the module ensures that energy data reaches every layer of the automation hierarchy, from field-level PLCs to plant-wide MES and ERP systems.
For facilities struggling with data silos, the 1426-M5E-DNT's CIP-native data model means energy measurements are immediately accessible as standard controller tags — no custom drivers, no OPC workarounds, no manual data entry. Production supervisors gain real-time energy cost visibility per production line, enabling informed decisions about load scheduling, demand response, and energy efficiency initiatives.
Remote monitoring capabilities allow maintenance engineers to diagnose power quality issues, review historical demand profiles, and configure alarm thresholds from any networked workstation — without requiring physical access to the switchgear room. This is particularly valuable for multi-site operations where centralized energy management teams need consistent visibility across geographically distributed facilities.
Every 1426-M5E-DNT unit supplied by NANKMOS undergoes pre-shipment functional testing to verify communication integrity on both EtherNet/IP and DeviceNet interfaces, measurement accuracy across all monitored parameters, and alarm output functionality. This ensures that the module is ready for immediate commissioning upon arrival, reducing installation time and eliminating field troubleshooting of hardware defects.
Q: Can the 1426-M5E-DNT operate on EtherNet/IP and DeviceNet simultaneously?A: Yes. The 1426-M5E-DNT is designed for concurrent dual-protocol operation. It maintains independent communication sessions on both EtherNet/IP and DeviceNet simultaneously, allowing data to be consumed by ControlLogix controllers via EtherNet/IP while legacy SLC 500 or DeviceNet-based systems access the same measurement data on the DeviceNet trunk — with no performance degradation on either network.
Q: What SCADA and HMI platforms are compatible with the 1426-M5E-DNT?A: The module is natively compatible with Rockwell Automation's FactoryTalk View SE and ME platforms via EtherNet/IP. It also integrates with third-party SCADA systems including Ignition (Inductive Automation), Wonderware System Platform, and any OPC-DA/UA server that supports EtherNet/IP drivers. DeviceNet connectivity extends compatibility to RSView32 and older FactoryTalk View installations.
Q: How does the 1426-M5E-DNT support remote diagnostics and predictive maintenance?A: The module exposes detailed power quality data — including harmonic spectrum, voltage unbalance, and demand interval records — as CIP data objects accessible over EtherNet/IP. This data can be polled by edge gateways, IoT platforms, or FactoryTalk Analytics for trend analysis and anomaly detection. Configurable alarm thresholds trigger network-visible fault objects that integrate with SCADA alarm management workflows, enabling remote diagnosis without physical site access.
Q: What warranty and quality assurance does NANKMOS provide for the 1426-M5E-DNT?A: All 1426-M5E-DNT units are covered by a 12-Month Warranty from the date of shipment. Each unit undergoes pre-shipment testing covering EtherNet/IP and DeviceNet communication verification, measurement accuracy validation, and alarm output confirmation. Units are shipped from verified in-stock inventory, with typical lead times of 1–3 business days. For volume orders or urgent requirements, contact [email protected] or +86 18359268345.
Functional Inspection100% tested on professional platforms to ensure stable performance.
Anti-static PackagingModules are packed in anti-static bags to prevent electrostatic damage.
Secure Export PackingCushion protection and strong cartons ensure safe transportation.
Worldwide ShippingGlobal logistics network supports air, sea and express delivery.
Documentation CheckPart number, revision and compatibility verified before shipment.
After-sales SupportProfessional technical support to help resolve your issues.