Functional Inspection100% tested on professional platforms to ensure stable performance.
GE UR6EH is a NANKMOS industrial automation product record. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.
Brand names are used for identification only.
GE UR6EH is a NANKMOS industrial automation product record. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.
| Manufacturer | GE |
|---|---|
| Application | Industrial Network Communication |
| Part Number / Model | UR6EH |
| Compatible System | PACSystems |
| Series | PACSystems |
| Condition Options | To Confirm |
| Module Type | Communication Module |
| Warranty | 12 Months |
| Packaging | Anti-static Bag / Secure Box |
| Shipping Methods | DHL / FedEx / UPS / Air / Sea |
| Availability | To Confirm |
| Lead Time | To Confirm |
| Documentation | Part number and revision checked before quote |
The GE IC695ETM001 is a high-performance Ethernet/IP communication module engineered for the GE PACSystems RX3i platform. Designed to serve as the backbone of industrial data exchange, the IC695ETM001 bridges field-level devices — sensors, actuators, remote I/O, and variable frequency drives — with upper-layer control and supervisory systems including PLCs, HMIs, SCADA platforms, and edge gateways. In smart factory environments where real-time data integrity and network stability are non-negotiable, this module delivers the protocol-level reliability that modern automation sites demand.
From signal acquisition at the field layer to data visualization at the enterprise level, the IC695ETM001 supports a complete and uninterrupted data flow chain. It enables the PACSystems RX3i controller to communicate seamlessly across Ethernet/IP-based architectures, ensuring that every process variable — temperature, pressure, flow, position, or drive status — is captured, transmitted, and acted upon without latency or data loss.
In a typical smart factory deployment, the IC695ETM001 sits at the heart of the control network, connecting the PACSystems RX3i CPU — such as the IC695CPE330 or IC695CPE302 — to a broader Ethernet/IP fabric. Field-level signals originate from distributed sensors and actuators wired into remote I/O modules like the IC694MDL660 digital input module or the IC694ALG220 analog input module. These signals are aggregated at the RX3i backplane and transmitted upstream via the IC695ETM001 to the supervisory layer.
On the network side, the IC695ETM001 connects through industrial-grade managed switches — such as those in the GE Multilin EDS series or compatible third-party switches supporting IEEE 802.3 — ensuring deterministic packet delivery across the plant floor. Variable frequency drives, including GE AF-650GP series drives, can be integrated as Ethernet/IP adapter nodes, allowing the PACSystems RX3i to issue speed references and read drive fault registers in real time.
HMI panels — including GE QuickPanel+ IC754 series terminals — connect directly to the Ethernet/IP network, pulling live process data from the RX3i controller through the IC695ETM001. This eliminates the need for serial protocol converters and reduces wiring complexity. SCADA platforms such as GE Cimplicity or third-party systems like Ignition by Inductive Automation communicate with the RX3i via OPC-UA or native Ethernet/IP drivers, enabling plant-wide data aggregation, trend logging, and alarm management.
For edge computing and IIoT connectivity, the IC695ETM001 supports integration with edge gateways that forward process data to cloud-based analytics platforms. Data from the RX3i — including cycle counts, energy consumption from power meters, and environmental readings from GE Multilin 850 protection relays — can be packaged and forwarded to MES or ERP systems, closing the loop between the shop floor and business intelligence layers.
Many industrial sites operate with fragmented communication architectures — legacy serial devices running Modbus RTU alongside newer Ethernet/IP nodes, with no unified data path to the SCADA layer. The IC695ETM001 addresses this by providing the PACSystems RX3i with a robust Ethernet/IP interface that can serve as the master node for all IP-addressable field devices, while the RX3i's additional communication slots handle legacy protocol bridging via modules such as the IC695CMM002 serial communications module.
Data silos — where drive data, sensor readings, and PLC diagnostics exist in separate, non-communicating systems — are eliminated when the IC695ETM001 is deployed as the central network interface. All device data converges at the RX3i controller and is made available to SCADA, HMI, and historian systems through a single, standardized Ethernet/IP connection. This architecture supports production line transparency: operators can monitor OEE metrics, track alarm histories, and initiate remote diagnostic sessions without physical access to the control panel.
Remote diagnostics via the IC695ETM001's web-based interface allow maintenance engineers to inspect module health, review communication statistics, and identify network faults from any connected workstation. Alarm feedback loops — from field device fault signals through the RX3i logic to SCADA alarm banners — are completed in milliseconds, enabling rapid response to process deviations. As production capacity grows, additional RX3i racks and Ethernet/IP nodes can be added to the network without architectural redesign, providing a scalable foundation for future smart factory expansion.
Q1: What is the communication latency of the IC695ETM001 in an Ethernet/IP network?The IC695ETM001 supports implicit I/O messaging with configurable Requested Packet Intervals (RPI) as low as 1 ms, making it suitable for time-sensitive control loops. Actual latency depends on network topology, switch configuration, and the number of active connections, but deterministic performance is achievable in properly segmented industrial Ethernet networks.
Q2: Is the IC695ETM001 compatible with third-party SCADA and HMI systems?Yes. The IC695ETM001 communicates via standard Ethernet/IP (CIP) protocol, which is supported by all major SCADA and HMI platforms including Wonderware, Ignition, iFIX, and Citect. OPC-DA and OPC-UA connectivity is available through GE Cimplicity or third-party OPC servers, enabling broad system integration without custom drivers.
Q3: How does the IC695ETM001 support remote diagnostics and network fault isolation?The module provides a built-in web server interface accessible via standard browser, displaying real-time connection status, error counters, and module diagnostics. Combined with the PACSystems RX3i fault table and SCADA alarm integration, maintenance teams can remotely identify communication faults, isolate affected nodes, and initiate corrective actions without on-site intervention.
Q4: What warranty and pre-shipment testing does NANKMOS provide for the IC695ETM001?Every IC695ETM001 unit supplied by NANKMOS undergoes 100% pre-shipment functional testing to verify communication integrity, backplane compatibility, and Ethernet/IP connectivity. All units are covered by a 12-month warranty from the date of shipment. In-stock units are available for immediate dispatch to minimize production downtime.
Functional Inspection100% tested on professional platforms to ensure stable performance.
Anti-static PackagingModules are packed in anti-static bags to prevent electrostatic damage.
Secure Export PackingCushion protection and strong cartons ensure safe transportation.
Worldwide ShippingGlobal logistics network supports air, sea and express delivery.
Documentation CheckPart number, revision and compatibility verified before shipment.
After-sales SupportProfessional technical support to help resolve your issues.