Global Industrial Automation Sourcing

EN  /  CN
NANKMOSEmpower Industry. Advance Future.
Send Inquiry

Schneider Electric PN072139P904

Schneider Electric PN072139P904 is a NANKMOS industrial automation product record. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.

Brand names are used for identification only.
Product Snapshot

Availability & Sourcing Details

Schneider Electric PN072139P904 is a NANKMOS industrial automation product record. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.

Drive Module Drive System Altivar Schneider Electric
Application
Motion Control & Drive System
Condition Options
New / Used / Refurbished
Availability
Confirmed by Email
Warranty
12 Months
Packaging
Anti-static Bag / Secure Box
Shipping
DHL / FedEx / UPS / Air / Sea

Product Information

ManufacturerSchneider Electric
ApplicationMotion Control & Drive System
Part Number / ModelPN072139P904
Compatible SystemAltivar
SeriesAltivar
Condition OptionsTo Confirm
Module TypeServo / Drive Module
Warranty12 Months
PackagingAnti-static Bag / Secure Box
Shipping MethodsDHL / FedEx / UPS / Air / Sea
AvailabilityTo Confirm
Lead TimeTo Confirm
DocumentationPart number and revision checked before quote
Product Details

PN072139P904 Product Description

The Schneider Electric PN072139P904 is a high-performance industrial network interface card engineered for Altivar variable frequency drive systems. Designed to bridge field-level devices with upper-layer control and monitoring platforms, this communication board enables seamless protocol conversion, real-time data exchange, and remote diagnostics across complex automation architectures. Whether deployed in power generation, petrochemical processing, water treatment, or advanced manufacturing, the PN072139P904 delivers the connectivity backbone that modern smart factories demand.

In today's Industry 4.0 environment, data continuity from the motor shaft to the SCADA dashboard is no longer optional — it is the operational standard. The PN072139P904 fulfills this requirement by acting as a certified protocol gateway between Altivar drive platforms and industrial fieldbus or Ethernet networks, eliminating data silos and enabling full-spectrum device visibility.

The PN072139P904 sits at the intersection of field instrumentation and enterprise data systems, enabling a complete and uninterrupted data flow chain across the automation hierarchy. At the field level, sensors — including vibration transducers, temperature probes, and pressure transmitters — feed analog or digital signals into the Altivar drive. The PN072139P904 captures this operational data and converts it into structured network packets compatible with upstream control systems.

In a typical smart factory deployment, the PN072139P904 connects the Altivar drive to a Schneider Electric Modicon M340 or M580 PLC via Modbus TCP over an industrial Ethernet backbone. The PLC aggregates drive status, speed reference, current draw, fault codes, and energy consumption data, forwarding it to a Wonderware InTouch or Vijeo Citect SCADA platform for real-time visualization and alarm management. Simultaneously, a Magelis HMIGTO HMI panel mounted at the control cabinet provides operators with live drive parameters and one-touch fault acknowledgment.

For distributed architectures, the PN072139P904 integrates with Schneider Electric ConneXium industrial Ethernet switches to maintain deterministic network timing across multi-node topologies. Remote I/O modules such as the Advantys STB series extend the network reach to field junction boxes, while Moxa NPort serial device servers bridge legacy RS-485 Modbus RTU instruments into the Ethernet segment without requiring hardware replacement.

At the edge, Schneider Electric EcoStruxure Machine Advisor or third-party edge gateways collect drive telemetry from the PN072139P904 and push it to cloud-based analytics platforms. This enables predictive maintenance algorithms to monitor motor load trends, detect bearing wear signatures, and schedule preventive interventions before unplanned downtime occurs. Energy metering modules such as the PowerLogic PM5000 series can be co-deployed on the same Modbus TCP segment, providing a unified energy and process data layer for MES reporting.

For PROFIBUS DP environments, the PN072139P904 connects directly to Siemens S7-300/S7-400 PLC DP master stations or Siemens ET 200S remote I/O distributed peripherals, enabling cross-vendor interoperability without protocol translation middleware. CANopen variants support integration with Lenze or SEW-Eurodrive motion controllers in coordinated multi-axis applications.

Many industrial facilities operate with fragmented communication architectures — legacy drives running proprietary serial protocols, newer PLCs expecting Ethernet-based data, and SCADA systems unable to reach field devices without manual data entry. The PN072139P904 directly resolves these structural data gaps.

Protocol Unification: Sites running mixed Modbus RTU, PROFIBUS, and CANopen networks can standardize drive communication through the PN072139P904, eliminating the need for external protocol converters and reducing wiring complexity. A single card installed in the Altivar drive option slot transforms the drive into a fully network-addressable node.

Eliminating Data Silos: Without a network interface, drive data — including fault history, energy consumption, and load profiles — remains trapped inside the drive's local memory. The PN072139P904 exposes this data to SCADA historians and MES databases in real time, enabling production transparency and regulatory compliance reporting.

Remote Monitoring and Diagnostics: Maintenance engineers can remotely read drive parameters, acknowledge faults, and adjust speed references from the SCADA workstation or mobile HMI without physical access to the control cabinet. This capability is critical for unmanned substations, offshore platforms, and geographically distributed pump stations.

Production Line Transparency: By integrating Altivar drives into the plant-wide data network via the PN072139P904, production managers gain real-time visibility into conveyor speeds, pump flow rates, compressor loads, and fan performance — all correlated with process variables from connected sensors and instruments.

Alarm Tracking and Event Logging: The PN072139P904 enables drive fault events to be timestamped and logged in the SCADA historian, supporting root-cause analysis, maintenance scheduling, and audit trail requirements for ISO 9001 and IEC 62443 compliance frameworks.

System Scalability: As production capacity expands, additional Altivar drives equipped with PN072139P904 cards can be added to the existing network segment without infrastructure changes, supporting phased automation upgrades and greenfield expansions alike.

Q1: What communication protocols does the PN072139P904 support, and is it compatible with my existing PLC network? The PN072139P904 supports Modbus TCP/IP, PROFIBUS DP, and CANopen protocols depending on the specific variant ordered. It is compatible with Schneider Electric Modicon PLCs, Siemens S7 series, ABB AC500, and other major PLC platforms that support these standard industrial protocols. Confirm your network protocol before ordering to ensure the correct variant is selected.

Q2: What is the typical communication latency, and is it suitable for real-time control applications? The PN072139P904 is designed for deterministic, low-latency data exchange. Modbus TCP cycle times are typically under 10 ms on a properly segmented industrial Ethernet network. PROFIBUS DP variants support cycle times as low as 1–5 ms depending on the number of nodes and baud rate configuration. It is suitable for real-time speed reference and torque control applications in coordinated drive systems.

Q3: Can the PN072139P904 be used for remote diagnostics and parameter configuration without on-site access? Yes. Once integrated into a SCADA or DCS network, the PN072139P904 exposes the full Altivar parameter set for remote read and write operations. Maintenance teams can remotely adjust acceleration ramps, current limits, and protection thresholds, as well as read fault codes and reset alarms — all without physical access to the drive. This capability is particularly valuable for remote pump stations, offshore installations, and unmanned substations.

Q4: Does the PN072139P904 come with a warranty, and has it been tested before shipment? Every PN072139P904 unit supplied by NANKMOS carries a 12-month warranty and undergoes pre-shipment functional testing to verify communication integrity, protocol handshake, and electrical compliance. In-stock units are available for immediate dispatch, supporting urgent maintenance and project commissioning timelines.

Quality & Delivery Assurance

Functional InspectionFunctional Inspection

100% tested on professional platforms to ensure stable performance.

Anti-static PackagingAnti-static Packaging

Modules are packed in anti-static bags to prevent electrostatic damage.

Secure Export PackingSecure Export Packing

Cushion protection and strong cartons ensure safe transportation.

Worldwide ShippingWorldwide Shipping

Global logistics network supports air, sea and express delivery.

Documentation CheckDocumentation Check

Part number, revision and compatibility verified before shipment.

After-sales SupportAfter-sales Support

Professional technical support to help resolve your issues.

Related Models Often Requested

View More Related Models