Allen-Bradley 1336-BDB-SP29D 74101-169-53

Allen-Bradley 1336-BDB-SP29D 74101-169-53 is a NANKMOS industrial automation product record Listed under Other series series and Business & Industrial > Automation, Control & Flow Devices. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.

Brand names are used for identification only.
Product Snapshot

Availability & Sourcing Details

Allen-Bradley 1336-BDB-SP29D 74101-169-53 is a NANKMOS industrial automation product record Listed under Other series series and Business & Industrial > Automation, Control & Flow Devices. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.

Automation Part Control System Allen-Bradley
Application
Industrial Automation Maintenance
Condition Options
New / Used / Refurbished
Availability
Confirmed by Email
Warranty
12 Months
Packaging
Anti-static Bag / Secure Box
Shipping
DHL / FedEx / UPS / Air / Sea

Product Information

ManufacturerAllen-Bradley
ApplicationIndustrial Automation Maintenance
Part Number / Model1336-BDB-SP29D 74101-169-53
Compatible SystemConfirmed by inquiry
Condition OptionsTo Confirm
Module TypeAutomation, Control & Flow Devices
Warranty12 Months
PackagingAnti-static Bag / Secure Box
Shipping MethodsDHL / FedEx / UPS / Air / Sea
AvailabilityTo Confirm
Lead TimeTo Confirm
DocumentationPart number and revision checked before quote
Product Details

1336-BDB-SP29D 74101-169-53 Product Description

The Allen-Bradley 1336-BDB-SP29D (Part No. 74101-169-53) is a dedicated communication gateway board engineered for the 1336 PLUS family of AC variable-frequency drives. Designed to bridge the gap between field-level drive hardware and plant-wide industrial networks, this module enables seamless data exchange across DeviceNet, DH-485, and Remote I/O backplane architectures — making it a critical link in any smart factory data chain. Whether you are integrating a single drive into a Logix-based control platform or scaling a multi-drive network across a distributed automation site, the 1336-BDB-SP29D delivers the protocol flexibility and network stability that modern industrial connectivity demands.

In a connected factory environment, the data journey begins at the drive itself. The 1336-BDB-SP29D captures real-time operating parameters — output frequency, motor current, fault codes, and drive status — and transmits them upstream through the network layer to supervisory systems. This live data stream feeds directly into FactoryTalk View SE HMI stations and RSView32 SCADA platforms, where operators can monitor drive health, track production throughput, and respond to alarm conditions without leaving the control room. The board's compatibility with the 1336 PLUS drive series means it slots directly into the existing drive chassis without additional hardware modification, reducing integration time and commissioning risk.

At the network layer, the 1336-BDB-SP29D connects to a ControlLogix or CompactLogix PLC via DeviceNet or DH-485, enabling the controller to issue speed references, start/stop commands, and parameter read/write operations in real time. This bidirectional communication architecture is essential for closed-loop process control in applications such as pump stations, conveyor systems, compressor drives, and HVAC fan arrays. When paired with a 1747-SDN DeviceNet Scanner or a 1756-DNB DeviceNet Bridge module in the ControlLogix rack, the gateway board becomes part of a fully deterministic control loop capable of sub-100ms scan cycle performance.

For sites operating mixed-protocol environments, the 1336-BDB-SP29D serves as a protocol translation point between the drive's internal communication bus and the plant network backbone. Remote I/O racks — such as the 1771-ASB adapter — can be daisy-chained downstream, extending the data collection reach to additional field devices including proximity sensors, pressure transmitters, and flow meters. This architecture eliminates data silos by consolidating field-level signals into a single network path that feeds the SCADA historian and MES layer above.

Remote diagnostics capability is one of the most operationally significant features enabled by the 1336-BDB-SP29D. Maintenance engineers can query drive fault logs, monitor thermal status, and verify parameter configurations from a remote workstation running RSLogix 5000 or Studio 5000 Logix Designer — without requiring physical access to the drive cabinet. This is particularly valuable in hazardous or hard-to-reach installations such as offshore platforms, water treatment facilities, and mining conveyor systems, where unplanned downtime carries significant operational cost.

Data visualization is further enhanced when the 1336-BDB-SP29D is integrated with edge gateway hardware such as the Moxa MGate MB3170 or a Kepware KEPServerEX OPC-UA server. These middleware layers translate the drive's native protocol data into OPC-UA or MQTT streams, making real-time drive metrics available to cloud-based analytics platforms and digital twin environments. This positions the 1336-BDB-SP29D not merely as a legacy communication board, but as a viable component in Industry 4.0 retrofit projects where existing 1336 PLUS drives are being brought into IIoT-connected architectures.

System expansion is straightforward. The 1336-BDB-SP29D supports multi-node network topologies, allowing multiple drives to share a single DeviceNet segment managed by the PLC scanner. As production capacity grows, additional 1336 PLUS drives equipped with the same gateway board can be added to the network without reconfiguring the existing nodes — a significant advantage for phased plant expansion projects. Network stability is maintained through the board's built-in termination and biasing support, which ensures signal integrity across longer cable runs typical of large industrial facilities.

Every 1336-BDB-SP29D unit supplied by NANKMOS undergoes pre-shipment functional testing, including communication handshake verification, parameter read/write validation, and network node address confirmation. Units are shipped with full documentation and are backed by a 12-month warranty covering manufacturing defects and communication failures. Stock is maintained for immediate dispatch, supporting both urgent replacement requirements and planned maintenance schedules.

The 1336-BDB-SP29D sits at the intersection of drive-level hardware and plant-wide network infrastructure. In a typical smart factory deployment, the data flow originates at the 1336 PLUS drive, where the gateway board captures motor speed, torque reference, output current, and fault status in real time. This data is transmitted via DeviceNet to a 1756-DNB DeviceNet Bridge module installed in the ControlLogix chassis, where the PLC processes the drive data alongside inputs from 1734 POINT I/O remote modules and 1769 CompactLogix analog input cards monitoring process variables such as pressure, temperature, and flow rate.

The PLC forwards aggregated process data upstream to a FactoryTalk View SE server, where operators interact with graphical HMI displays showing drive status, alarm history, and production KPIs. Simultaneously, the FactoryTalk Historian captures time-series data from the drive network, enabling trend analysis and predictive maintenance workflows. For sites using third-party SCADA platforms, a Kepware KEPServerEX OPC-DA/UA server bridges the Allen-Bradley network to Wonderware InTouch or Ignition SCADA, ensuring cross-platform data availability. At the edge, a Moxa EDS-308 industrial managed switch provides the Ethernet backbone that interconnects the PLC rack, HMI workstations, and historian server — maintaining network segmentation and deterministic data delivery across the factory floor.

Many industrial sites operating 1336 PLUS drives face a common challenge: the drives contain valuable operational data — fault histories, energy consumption metrics, load profiles — that remains inaccessible to the plant SCADA or MES system due to missing or failed communication hardware. The 1336-BDB-SP29D directly resolves this data gap by restoring the drive's network connectivity, enabling the SCADA system to poll drive parameters on every scan cycle and log fault events with millisecond-level timestamps.

Protocol fragmentation is another frequent barrier. Sites that have evolved from legacy Remote I/O architectures to modern DeviceNet or EtherNet/IP backbones often find that older drives lack the communication boards needed to participate in the new network. The 1336-BDB-SP29D bridges this transition, allowing 1336 PLUS drives to remain productive assets within a modernized control architecture rather than requiring full drive replacement. This approach significantly reduces capital expenditure while extending the operational life of existing drive investments.

For remote monitoring and alarm management, the gateway board enables the SCADA system to receive drive fault notifications in real time, triggering automated alarm workflows that notify maintenance personnel via email or SMS before a fault escalates to an unplanned shutdown. Production line transparency is further improved by mapping drive speed references and actual output values to OEE dashboards, giving plant managers visibility into drive utilization rates and energy efficiency metrics across the entire production floor.

Q1: What communication protocols does the 1336-BDB-SP29D support? The 1336-BDB-SP29D supports DeviceNet, DH-485, and Remote I/O protocols, enabling integration with ControlLogix, CompactLogix, and SLC 500 PLC platforms. It is compatible with 1756-DNB and 1747-SDN scanner modules for DeviceNet network management.

Q2: Can this board be used in an existing 1336 PLUS drive without drive replacement? Yes. The 1336-BDB-SP29D is designed as a plug-in communication option board for the 1336 PLUS drive series. It installs directly into the drive's communication option slot without requiring drive firmware changes or hardware modification, minimizing installation downtime.

Q3: How does the board support remote diagnostics and network stability? Once installed, the 1336-BDB-SP29D allows RSLogix 5000 or Studio 5000 to remotely query drive fault logs, monitor real-time operating parameters, and verify network node status. The board supports standard DeviceNet termination and biasing, ensuring signal integrity across multi-node network segments and reducing the risk of communication dropouts in electrically noisy industrial environments.

Q4: What warranty and pre-shipment testing does NANKMOS provide? Every 1336-BDB-SP29D unit is covered by a 12-month warranty against manufacturing defects and communication failures. Prior to shipment, each unit undergoes functional testing including communication handshake verification, network node address confirmation, and parameter read/write validation. Units are in stock and available for immediate dispatch to support both emergency replacement and planned maintenance requirements.

Quality & Delivery Assurance

Functional InspectionFunctional Inspection

100% tested on professional platforms to ensure stable performance.

Anti-static PackagingAnti-static Packaging

Modules are packed in anti-static bags to prevent electrostatic damage.

Secure Export PackingSecure Export Packing

Cushion protection and strong cartons ensure safe transportation.

Worldwide ShippingWorldwide Shipping

Global logistics network supports air, sea and express delivery.

Documentation CheckDocumentation Check

Part number, revision and compatibility verified before shipment.

After-sales SupportAfter-sales Support

Professional technical support to help resolve your issues.

Related Models Often Requested

View More Related Models