Functional Inspection100% tested on professional platforms to ensure stable performance.
Allen-Bradley 1336-MOD-KB010 is a NANKMOS industrial automation product record. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.
Brand names are used for identification only.
Allen-Bradley 1336-MOD-KB010 is a NANKMOS industrial automation product record. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.
| Manufacturer | Allen-Bradley |
|---|---|
| Application | Industrial Network Communication |
| Part Number / Model | 1336-MOD-KB010 |
| Compatible System | Confirmed by inquiry |
| Condition Options | To Confirm |
| Module Type | Communication Module |
| Warranty | 12 Months |
| Packaging | Anti-static Bag / Secure Box |
| Shipping Methods | DHL / FedEx / UPS / Air / Sea |
| Availability | To Confirm |
| Lead Time | To Confirm |
| Documentation | Part number and revision checked before quote |
The Allen-Bradley 1336-MOD-KB010 is a dedicated network interface module engineered for the 1336 PLUS family of AC variable frequency drives, enabling seamless integration into DeviceNet and Data Highway Plus (DH+) industrial communication architectures. In modern smart factory environments, the ability to connect drive-level assets directly into the plant-wide data backbone is no longer optional — it is the foundation of real-time production visibility, predictive maintenance, and closed-loop automation. The 1336-MOD-KB010 serves as the critical data bridge between the drive's internal control logic and the upper-layer control and monitoring systems that govern the entire production line.
Deployed across manufacturing, energy, water treatment, and process industries, this module enables the 1336 PLUS drive to participate fully in a networked automation cell. Drive status, speed reference, output frequency, fault codes, and operational parameters are continuously transmitted across the DeviceNet segment to the controlling PLC — typically a Rockwell Automation ControlLogix or CompactLogix platform — where they are processed, logged, and acted upon in real time. This eliminates the traditional reliance on hardwired analog and discrete I/O for drive supervision, replacing it with a single, deterministic digital communication channel that carries both command and diagnostic data simultaneously.
Understanding the 1336-MOD-KB010 requires viewing it within the complete industrial data chain rather than as a standalone component. In a typical smart factory deployment, the data flow originates at the field device level — sensors, encoders, and process transmitters feed real-time signals into the 1336 PLUS drive, which regulates motor speed and torque in response. The 1336-MOD-KB010 then captures the drive's operational state and transmits it upstream via DeviceNet to a 1756-DNB DeviceNet Scanner module seated in a ControlLogix chassis. From there, the data enters the ControlLogix backplane and is processed by the L7x series controller, which executes the automation logic and forwards aggregated production data to the plant SCADA layer.
At the SCADA and HMI level, platforms such as Rockwell FactoryTalk View SE or PanelView Plus 7 terminals consume the drive data to display real-time speed, current draw, fault status, and energy consumption on operator dashboards. Alongside the 1336-MOD-KB010, installations commonly incorporate 1336 PLUS peripheral modules such as the 1336-MOD-L2 for additional I/O expansion, and 1336-BRF series dynamic braking resistors for controlled deceleration in high-inertia applications. The network segment itself is typically managed through 1783-MS10T Stratix managed industrial Ethernet switches, which provide the Layer 2 infrastructure for time-sensitive data delivery across the production floor.
For remote I/O integration, POINT I/O 1734-AENT adapters and FLEX I/O 1794-AENT modules extend the network reach to distributed field panels, collecting discrete and analog signals from proximity sensors, pressure transmitters, and flow meters. These signals are synchronized with the drive data from the 1336-MOD-KB010 to provide a unified process view within the ControlLogix controller. In facilities running multi-drive architectures, the 1336-MOD-KB010 enables each drive node on the DeviceNet segment to be individually addressed, monitored, and commanded — supporting up to 64 nodes per network segment without requiring additional gateways or protocol converters. Edge computing nodes such as the Rockwell 1756-EN2T EtherNet/IP bridge module can further aggregate this data and forward it to cloud-based MES or ERP platforms for production analytics and OEE reporting.
Many industrial facilities operating legacy 1336 PLUS drive installations face a common set of challenges: drives that run in isolation without network visibility, fault events that go unlogged until a production stoppage occurs, and maintenance teams that must physically walk the floor to check drive status. The 1336-MOD-KB010 directly resolves these data gaps by bringing every connected drive into the plant network as a fully addressable, data-producing node.
Protocol fragmentation is one of the most persistent barriers to plant-wide transparency. Sites that mix DeviceNet-based drive control with DH+ legacy PLC networks — common in facilities running SLC 500 or PLC-5 controllers alongside newer ControlLogix systems — benefit from the 1336-MOD-KB010's dual-protocol support, which allows the drive to communicate across both network types without requiring a separate protocol gateway. This eliminates a common source of data islands where drive-level information is trapped behind incompatible communication layers.
Remote diagnostics capability is another critical value delivered by this module. When a 1336 PLUS drive enters a fault condition — whether due to overcurrent, overtemperature, or communication loss — the 1336-MOD-KB010 transmits the fault code and timestamp directly to the SCADA historian, enabling maintenance engineers to diagnose the root cause remotely before dispatching a technician. This reduces mean time to repair (MTTR) and supports the shift from reactive to predictive maintenance strategies. For facilities pursuing IIoT and Industry 4.0 roadmaps, the 1336-MOD-KB010 provides the foundational connectivity layer that makes drive-level data available for advanced analytics, alarm management, and digital twin modeling.
Q1: What communication protocols does the 1336-MOD-KB010 support, and is it compatible with modern ControlLogix systems? The 1336-MOD-KB010 supports DeviceNet and Data Highway Plus (DH+) protocols. It is fully compatible with ControlLogix and CompactLogix platforms via a 1756-DNB DeviceNet Scanner, as well as legacy SLC 500 and PLC-5 systems on DH+ networks. This dual-protocol capability makes it suitable for both greenfield smart factory deployments and brownfield upgrades.
Q2: How does this module contribute to network stability and deterministic data delivery in high-cycle production environments? DeviceNet is a deterministic, producer-consumer network protocol that guarantees message delivery within defined cycle times. The 1336-MOD-KB010 leverages this architecture to ensure that drive status and command data are exchanged at consistent intervals regardless of network load, supporting stable closed-loop control in high-speed manufacturing and process applications.
Q3: Can the 1336-MOD-KB010 support remote diagnostics and fault logging without on-site intervention? Yes. Once integrated into a DeviceNet or DH+ network, the module continuously transmits drive fault codes, operational parameters, and status flags to the connected PLC and SCADA system. Maintenance teams can monitor drive health, review fault histories, and initiate remote resets through the SCADA HMI without requiring physical access to the drive panel, significantly reducing unplanned downtime.
Q4: What warranty and pre-shipment testing does NANKMOS provide for the 1336-MOD-KB010? Every 1336-MOD-KB010 unit supplied by NANKMOS is covered by a 12-Month Warranty against manufacturing defects and functional failures. Prior to dispatch, each unit undergoes functional verification and communication interface testing to confirm protocol compatibility and signal integrity. Units are held in climate-controlled inventory and shipped with full traceability documentation to support incoming inspection at the customer's facility.
Functional Inspection100% tested on professional platforms to ensure stable performance.
Anti-static PackagingModules are packed in anti-static bags to prevent electrostatic damage.
Secure Export PackingCushion protection and strong cartons ensure safe transportation.
Worldwide ShippingGlobal logistics network supports air, sea and express delivery.
Documentation CheckPart number, revision and compatibility verified before shipment.
After-sales SupportProfessional technical support to help resolve your issues.