Global Industrial Automation Sourcing

EN  /  CN
NANKMOSEmpower Industry. Advance Future.
Send Inquiry

Allen-Bradley 1336T-GTB-SP1B 1336T-LM1EN 74103-015-51 74101-

Allen-Bradley 1336T-GTB-SP1B 1336T-LM1EN 74103-015-51 74101-954-51D is a NANKMOS industrial automation product record Listed under Other series series and Business & Industrial > Automation, Control & Flow Devices. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.

Brand names are used for identification only.
Product Snapshot

Availability & Sourcing Details

Allen-Bradley 1336T-GTB-SP1B 1336T-LM1EN 74103-015-51 74101-954-51D is a NANKMOS industrial automation product record Listed under Other series series and Business & Industrial > Automation, Control & Flow Devices. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.

Automation Part Control System Allen-Bradley
Application
Industrial Automation Maintenance
Condition Options
New / Used / Refurbished
Availability
Confirmed by Email
Warranty
12 Months
Packaging
Anti-static Bag / Secure Box
Shipping
DHL / FedEx / UPS / Air / Sea

Product Information

ManufacturerAllen-Bradley
ApplicationIndustrial Automation Maintenance
Part Number / Model1336T-GTB-SP1B 1336T-LM1EN 74103-015-51 74101-954-51D
Compatible SystemConfirmed by inquiry
Condition OptionsTo Confirm
Module TypeAutomation, Control & Flow Devices
Warranty12 Months
PackagingAnti-static Bag / Secure Box
Shipping MethodsDHL / FedEx / UPS / Air / Sea
AvailabilityTo Confirm
Lead TimeTo Confirm
DocumentationPart number and revision checked before quote
Product Details

1336T-GTB-SP1B 1336T-LM1EN 74103-015-51 74101-954-51D Product Description

The Allen-Bradley 1336T-GTB-SP1B is a dedicated communication gateway board engineered for the 1336 PLUS family of AC drives, enabling seamless integration between field-level drive systems and upper-layer industrial networks. Designed to bridge the gap between legacy drive architectures and modern smart factory infrastructure, this gateway board supports DeviceNet and Data Highway Plus (DH+) communication protocols, allowing the 1336 PLUS drive to participate fully in distributed control architectures. In environments where production transparency, real-time diagnostics, and network-level drive management are critical, the 1336T-GTB-SP1B delivers the connectivity backbone that modern automation sites demand.

As industrial facilities transition toward connected factory models, the ability to integrate variable frequency drives into SCADA systems, PLC networks, and HMI platforms without replacing existing hardware becomes a strategic priority. The 1336T-GTB-SP1B addresses this need directly — it slots into the 1336 PLUS drive's option bay and immediately extends the drive's communication reach across the plant network. Drive parameters, fault codes, speed references, and status data become accessible from any node on the connected network, enabling centralized monitoring, remote parameter adjustment, and predictive maintenance workflows that reduce unplanned downtime.

In a typical smart factory data flow, field sensors and actuators feed signals into the 1336 PLUS drive, which regulates motor speed and torque in response to process demands. The 1336T-GTB-SP1B captures this operational data and transmits it upstream via DeviceNet to a ControlLogix or CompactLogix PLC — such as the 1756-L73 or 1769-L33ER — where ladder logic processes the data and issues control commands back to the drive in real time. Simultaneously, the DH+ channel connects the drive to legacy PLC-5 or SLC 500 controllers still operating in mixed-generation plants, ensuring backward compatibility without costly controller replacement. From the PLC layer, data flows to SCADA platforms via EtherNet/IP gateways such as the 1756-ENBT or 1756-EN2T communication modules, where operators monitor drive performance on FactoryTalk View SE or Wonderware InTouch dashboards.

The 1336T-GTB-SP1B also plays a critical role in remote I/O architectures. When paired with 1771 Remote I/O adapters or FLEX I/O modules such as the 1794-ADN DeviceNet adapter, the gateway enables distributed I/O nodes across the production floor to share a unified network with the drive system. This eliminates point-to-point wiring between the drive and remote control panels, reduces installation complexity, and improves signal integrity across long cable runs in electrically noisy industrial environments. The result is a leaner, more maintainable wiring infrastructure that supports rapid reconfiguration as production layouts evolve.

For facilities operating Profibus DP or Modbus RTU devices alongside Allen-Bradley equipment, protocol conversion gateways such as the ProSoft Technology MVI56-MCM or HMS Anybus X-gateway can be deployed upstream of the 1336T-GTB-SP1B to normalize data formats before they reach the SCADA layer. This multi-protocol architecture ensures that the 1336 PLUS drive's operational data integrates cleanly with third-party sensors, transmitters, and analyzers without requiring custom software bridges. Edge computing nodes — including Rockwell's Stratix 5400 industrial switches and Cisco IE 4000 series — provide the network switching fabric that carries all this data reliably across the plant floor Ethernet backbone.

Remote diagnostics capability is one of the most operationally significant features enabled by the 1336T-GTB-SP1B. Maintenance engineers can query drive fault history, monitor real-time current draw, check DC bus voltage, and review output frequency data from a central control room or even a remote VPN connection — without walking the production floor. When a fault condition occurs, the gateway transmits the fault code and timestamp to the SCADA alarm management system, which logs the event, triggers operator notifications, and initiates predefined response workflows. This closed-loop alarm-to-response architecture dramatically reduces mean time to repair (MTTR) and supports compliance with IEC 62443 industrial cybersecurity frameworks for remote access management.

Every 1336T-GTB-SP1B unit supplied by NANKMOS undergoes pre-shipment functional verification, including communication handshake testing, parameter read/write validation, and network node address confirmation. Units are shipped with full documentation and are backed by a 12-month warranty covering manufacturing defects and communication failures. Stock is maintained for immediate dispatch, with lead times confirmed at order placement for high-volume requirements.

The 1336T-GTB-SP1B sits at the intersection of drive-level control and plant-wide network communication, making it a foundational component in connected factory architectures. At the field level, process sensors — including pressure transmitters, flow meters, and temperature sensors wired to 1794-IB16 FLEX I/O input modules — deliver analog and digital signals to the 1336 PLUS drive's control logic. The gateway board then encapsulates drive status, speed feedback, and fault data into DeviceNet message frames and transmits them to the plant's primary PLC — typically a ControlLogix 1756-L73 or a CompactLogix 1769-L33ER — via the DeviceNet scanner module 1756-DNB.

From the PLC, processed data travels over EtherNet/IP to the SCADA server running FactoryTalk Historian or OSIsoft PI, where it is time-stamped, stored, and made available for trend analysis and KPI dashboards. HMI panels — such as the PanelView Plus 7 or PanelView 800 — display real-time drive parameters including output frequency, motor current, and fault status directly on the production floor, giving operators immediate visibility without requiring access to the control room. For legacy DH+ segments still present in older plant sections, the 1336T-GTB-SP1B's DH+ port connects directly to PLC-5 controllers or SLC 5/04 processors, maintaining bidirectional parameter exchange without protocol conversion overhead.

At the network infrastructure layer, Stratix 5400 managed industrial switches provide the Ethernet switching fabric that interconnects PLCs, SCADA servers, HMI panels, and edge gateways. Where wireless connectivity is required for mobile HMI or remote I/O nodes in hard-to-wire areas, Cisco IE 4010 industrial wireless access points extend the network reach without compromising deterministic communication timing. Data collected across this architecture feeds into MES (Manufacturing Execution System) platforms, enabling production scheduling, quality tracking, and OEE (Overall Equipment Effectiveness) calculations that drive continuous improvement programs.

Many industrial facilities operating 1336 PLUS drives face a common set of connectivity challenges: drives that run in isolation without network visibility, protocol mismatches between legacy DH+ segments and modern EtherNet/IP infrastructure, and the inability to access drive fault history remotely when troubleshooting production stoppages. The 1336T-GTB-SP1B directly resolves these issues by providing a native communication interface that requires no external protocol converter for DeviceNet or DH+ environments.

Data silos — where drive operational data exists only in the drive's local memory and is inaccessible to SCADA or MES systems — are eliminated once the gateway board is installed. Drive parameters become readable and writable from any authorized PLC node or SCADA workstation on the network, enabling centralized parameter management across multiple drives from a single engineering workstation running RSLogix 5000 or Studio 5000 Logix Designer. This centralization reduces configuration errors, accelerates commissioning, and ensures that parameter changes are logged and auditable.

For production line transparency, the gateway enables real-time monitoring of motor load trends, which allows maintenance teams to identify mechanical wear patterns — such as increasing current draw on a conveyor drive — before they escalate into unplanned failures. Alarm tracking is enhanced because fault codes are transmitted to the SCADA alarm server with precise timestamps, enabling root cause analysis that correlates drive faults with upstream process events. System expansion is simplified as well: adding a new 1336 PLUS drive to an existing DeviceNet segment requires only node address configuration on the new gateway board, with no rewiring of the network trunk.

Q: What communication protocols does the 1336T-GTB-SP1B support, and is it compatible with EtherNet/IP networks? A: The 1336T-GTB-SP1B natively supports DeviceNet and Data Highway Plus (DH+) protocols, as well as Allen-Bradley Remote I/O. It does not provide a direct EtherNet/IP port; however, it integrates seamlessly into EtherNet/IP architectures when the DeviceNet network is connected to a ControlLogix PLC equipped with a 1756-ENBT or 1756-EN2T EtherNet/IP bridge module, allowing drive data to be accessed from any EtherNet/IP node on the plant network.

Q: How does the gateway handle network latency in real-time control applications? A: DeviceNet is a deterministic fieldbus protocol with configurable Expected Packet Rate (EPR) settings, allowing the 1336T-GTB-SP1B to deliver drive status updates at intervals as low as 10 ms in polled I/O mode. For time-critical speed reference commands, the gateway supports explicit messaging and I/O messaging simultaneously, ensuring that control commands are delivered within the network's configured scan time without competing with diagnostic data traffic.

Q: Can the 1336T-GTB-SP1B be used for remote diagnostics and parameter changes without on-site access? A: Yes. Once the gateway is integrated into a DeviceNet or DH+ network connected to a SCADA or PLC system with remote access capability, authorized engineers can read drive fault logs, monitor real-time operational parameters, and write parameter changes remotely via VPN-secured connections to the plant network. This capability supports predictive maintenance programs and reduces the need for on-site service visits for routine parameter adjustments or fault investigations.

Q: What does the 12-month warranty cover, and what is the typical lead time for orders? A: The 12-month warranty provided by NANKMOS covers manufacturing defects and communication failures identified under normal operating conditions. Units in stock are available for immediate dispatch following order confirmation, with shipping documentation and test records included. For high-volume or project-based orders, lead times are confirmed at the time of quotation. Contact NANKMOS at [email protected] or +86 18359268345 for availability and pricing.

Quality & Delivery Assurance

Functional InspectionFunctional Inspection

100% tested on professional platforms to ensure stable performance.

Anti-static PackagingAnti-static Packaging

Modules are packed in anti-static bags to prevent electrostatic damage.

Secure Export PackingSecure Export Packing

Cushion protection and strong cartons ensure safe transportation.

Worldwide ShippingWorldwide Shipping

Global logistics network supports air, sea and express delivery.

Documentation CheckDocumentation Check

Part number, revision and compatibility verified before shipment.

After-sales SupportAfter-sales Support

Professional technical support to help resolve your issues.

Related Models Often Requested

View More Related Models