Functional Inspection100% tested on professional platforms to ensure stable performance.
Pepperl+Fuchs IR-SENS V 14036-PE44-AGN1 LAM 796-901039-002 1075326 is a NANKMOS industrial automation product record Listed under Other series series and Business & Industrial > Automation, Control & Flow Devices. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.
Brand names are used for identification only.
Pepperl+Fuchs IR-SENS V 14036-PE44-AGN1 LAM 796-901039-002 1075326 is a NANKMOS industrial automation product record Listed under Other series series and Business & Industrial > Automation, Control & Flow Devices. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.
| Manufacturer | Pepperl+Fuchs |
|---|---|
| Application | Industrial Automation Maintenance |
| Part Number / Model | IR-SENS V 14036-PE44-AGN1 LAM 796-901039-002 1075326 |
| Compatible System | Confirmed by inquiry |
| Condition Options | To Confirm |
| Module Type | Automation, Control & Flow Devices |
| Warranty | 12 Months |
| Packaging | Anti-static Bag / Secure Box |
| Shipping Methods | DHL / FedEx / UPS / Air / Sea |
| Availability | To Confirm |
| Lead Time | To Confirm |
| Documentation | Part number and revision checked before quote |
The Pepperl+Fuchs IR-SENS-V-14036 (full part number: IR-SENS V 14036-PE44-AGN1 LAM 796-901039-002 / 1075326) is a precision infrared sensor interface engineered for the LAM 796 series, purpose-built to bridge field-level optical sensing with upper-layer industrial Ethernet and fieldbus networks. In modern smart factory environments where data continuity from sensor to cloud is non-negotiable, the IR-SENS-V-14036 delivers a robust, protocol-transparent communication backbone that connects infrared detection signals into the broader automation data chain — spanning PLC controllers, remote I/O modules, HMI panels, SCADA platforms, and edge gateways without signal loss or latency compromise.
Designed for demanding industrial environments, this interface supports IO-Link master integration, enabling seamless parameter assignment, real-time diagnostics, and event-driven alarm forwarding directly from the sensor layer. When paired with a Pepperl+Fuchs ICE1-8IOL-G60L-V1D IO-Link master or similar IO-Link hub, the IR-SENS-V-14036 becomes a fully addressable node on the factory network — readable by any PROFINET controller or Modbus TCP SCADA host without additional protocol converters.
In a fully integrated smart factory data architecture, the IR-SENS-V-14036 occupies a critical position at the field device layer. The data flow begins at the infrared sensing element of the LAM 796 optical system, where the IR-SENS-V-14036 captures detection events and encodes them as IO-Link process data frames. These frames are forwarded upstream to an IO-Link master — such as the Pepperl+Fuchs AL1100 or ICE2-8IOL-G65L-V1D — which aggregates multi-channel sensor data and presents it as a unified PROFINET device on the plant network.
From the PROFINET backbone, a Siemens S7-1500 PLC or equivalent controller reads real-time sensor states, executes logic, and writes control outputs back to actuators on the same network segment. Simultaneously, a Pepperl+Fuchs LB remote I/O module or similar distributed I/O rack can extend the network reach to field cabinets located hundreds of meters from the control room, maintaining sub-millisecond cycle times across Industrial Ethernet switches such as the Pepperl+Fuchs IEPS-T099A managed switch series.
At the supervisory layer, a Wonderware or Ignition SCADA platform subscribes to Modbus TCP tags exposed by the IR-SENS-V-14036 data path, enabling real-time visualization of detection counts, signal quality metrics, and fault states on operator HMI screens. When an infrared beam interruption event occurs — indicating a part presence, conveyor jam, or safety zone breach — the alarm is propagated within one scan cycle to the SCADA alarm server, logged with timestamp and device ID, and forwarded via OPC-UA to the MES or ERP layer for production traceability.
For installations requiring edge intelligence, a Pepperl+Fuchs IDENT or compatible edge gateway can pre-process IR-SENS-V-14036 data locally, applying filtering and aggregation before forwarding condensed datasets to cloud analytics platforms — reducing bandwidth consumption while preserving event fidelity. Variable frequency drives (VFDs) controlling conveyor motors can also receive speed-adjustment commands derived from IR-SENS-V-14036 detection patterns, enabling adaptive throughput control without PLC intervention.
Protocol Fragmentation: Many legacy automation sites run a mix of PROFIBUS DP, Modbus RTU, and proprietary sensor buses alongside modern Industrial Ethernet. The IR-SENS-V-14036, operating within the IO-Link and PROFINET ecosystem, eliminates the need for standalone protocol converters by presenting a standardized interface that any PROFINET-capable controller can address natively. For sites still running PROFIBUS, a Pepperl+Fuchs DP/PA coupler or gateway bridges the protocol gap without rewiring.
Data Islands and Blind Spots: Infrared sensors deployed without network integration create data islands — detection events are local and invisible to SCADA or MES systems. The IR-SENS-V-14036 dissolves these islands by making every detection event a network-visible, timestamped data point accessible to any authorized system on the plant LAN.
Remote Monitoring and Diagnostics: Maintenance teams no longer need physical access to diagnose IR-SENS-V-14036 performance. IO-Link diagnostic data — including signal strength, contamination warnings, and communication error counts — is readable remotely via the PROFINET controller or directly through a web-based IO-Link master interface. This enables predictive maintenance scheduling and reduces unplanned downtime.
Production Line Transparency: By feeding IR-SENS-V-14036 detection data into SCADA dashboards, production managers gain real-time visibility into part flow rates, cycle times, and anomaly patterns. Alarm tracking is automated: threshold breaches trigger notifications to mobile devices, shift logs, and maintenance ticketing systems without manual intervention.
System Scalability: The IO-Link and PROFINET architecture underlying the IR-SENS-V-14036 is inherently scalable. Adding new sensor nodes, expanding to additional production lines, or integrating new HMI stations requires only network configuration changes — no hardware rewiring. This future-proofs the investment and supports phased smart factory rollouts.
Q1: What communication protocols does the IR-SENS-V-14036 support, and is it compatible with existing PROFINET networks? The IR-SENS-V-14036 operates natively within the IO-Link standard (IEC 61131-9) and integrates into PROFINET and Modbus TCP networks via compatible IO-Link masters. It is fully compatible with any PROFINET RT controller, including Siemens, Beckhoff, and Rockwell platforms, without requiring additional protocol gateways.
Q2: How does the IR-SENS-V-14036 support remote diagnostics and predictive maintenance? IO-Link provides bidirectional communication between the IR-SENS-V-14036 and the IO-Link master, transmitting not only process values but also device diagnostic data — signal quality, error counters, and operational hours. This data is accessible remotely via the PROFINET controller or SCADA system, enabling condition-based maintenance without on-site inspection.
Q3: What is the network latency performance, and is it suitable for real-time control applications? The IR-SENS-V-14036 communicates via IO-Link at cycle times as low as 2.3 ms (COM3 mode), with PROFINET RT ensuring deterministic data delivery at the controller level. This performance is suitable for high-speed detection applications including conveyor tracking, part counting, and safety interlock systems.
Q4: What warranty and pre-shipment testing does NANKMOS provide for the IR-SENS-V-14036? Every IR-SENS-V-14036 unit supplied by NANKMOS carries a 12-month warranty covering manufacturing defects and communication failures under normal operating conditions. Units undergo pre-shipment functional verification including IO-Link communication handshake testing and visual inspection. For volume orders, extended testing protocols and batch certificates are available upon request. Contact [email protected] or +86 18359268345 for procurement support.
Functional Inspection100% tested on professional platforms to ensure stable performance.
Anti-static PackagingModules are packed in anti-static bags to prevent electrostatic damage.
Secure Export PackingCushion protection and strong cartons ensure safe transportation.
Worldwide ShippingGlobal logistics network supports air, sea and express delivery.
Documentation CheckPart number, revision and compatibility verified before shipment.