Global Industrial Automation Sourcing

EN  /  CN
NANKMOSEmpower Industry. Advance Future.
Send Inquiry

Phoenix Contact QUINT-PS/1AC/48DC/5 2866679

Phoenix Contact QUINT-PS/1AC/48DC/5 2866679 is a NANKMOS industrial automation product record Listed under Other series series and Power Supplies. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.

Brand names are used for identification only.
Product Snapshot

Availability & Sourcing Details

Phoenix Contact QUINT-PS/1AC/48DC/5 2866679 is a NANKMOS industrial automation product record Listed under Other series series and Power Supplies. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.

Power Module Control System Phoenix Contact
Application
Control System Power Support
Condition Options
New / Used / Refurbished
Availability
Confirmed by Email
Warranty
12 Months
Packaging
Anti-static Bag / Secure Box
Shipping
DHL / FedEx / UPS / Air / Sea

Product Information

ManufacturerPhoenix Contact
ApplicationControl System Power Support
Part Number / ModelQUINT-PS/1AC/48DC/5 2866679
Compatible SystemConfirmed by inquiry
Condition OptionsTo Confirm
Module TypePower Supply Module
Warranty12 Months
PackagingAnti-static Bag / Secure Box
Shipping MethodsDHL / FedEx / UPS / Air / Sea
AvailabilityTo Confirm
Lead TimeTo Confirm
DocumentationPart number and revision checked before quote
Product Details

QUINT-PS/1AC/48DC/5 2866679 Product Description

The Phoenix Contact QUINT-PS/1AC/48DC/5 (Article No. 2866679) is a high-performance 48 VDC / 5 A DIN-rail power supply engineered to sustain the uninterrupted power demands of modern industrial communication networks. Designed for single-phase AC input (100–240 VAC), it delivers a stable 48 VDC output that directly supports PROFIBUS DP segment repeaters, PROFINET managed switches, EtherNet/IP infrastructure nodes, and OPC-UA gateway devices — all of which require clean, regulated DC power to maintain deterministic data transmission across the factory floor.

In smart factory environments, power quality is inseparable from data integrity. A voltage sag or transient at the power rail can corrupt a PROFIBUS telegram, delay a PROFINET cyclic frame, or trigger a false alarm in a SCADA supervisory system. The QUINT-PS series addresses this with its patented SFB (Selective Fuse Breaking) technology, which delivers up to 200% overload current for 12 ms to selectively blow downstream fuses without tripping the supply — keeping the rest of the network segment alive and the data flow uninterrupted.

In a fully integrated smart factory, the QUINT-PS/1AC/48DC/5 2866679 sits at the heart of the cabinet power rail, supplying the 48 VDC bus that energises every node in the industrial communication chain. The data flow begins at the field level: sensors, actuators, and encoders transmit process values to remote I/O modules — such as the Phoenix Contact Axioline F or Inline IL series — which aggregate signals and forward them upstream via PROFINET IO or PROFIBUS DP to the PLC controller.

The PLC — typically a Phoenix Contact RFC 460R PN 3TX or a Siemens S7-series controller — processes the incoming I/O data and issues control commands back to field devices. Managed industrial Ethernet switches, such as the Phoenix Contact FL SWITCH 2008 or FL SWITCH 4808E, form the PROFINET backbone, routing cyclic process data and acyclic diagnostic frames between the PLC, HMI panels, and SCADA servers with sub-millisecond determinism. All of these switches and their connected nodes depend on a stable 48 VDC supply — precisely what the QUINT-PS/1AC/48DC/5 delivers.

At the HMI layer, operator panels such as the Phoenix Contact TP 3057T or third-party Weintek and Siemens TP700 Comfort panels connect to the PROFINET ring and display real-time process data pulled from the SCADA historian. The SCADA platform — whether Ignition, WinCC, or iFIX — communicates with field devices via OPC-UA servers embedded in protocol gateways such as the Phoenix Contact FL mGuard RS4000 or Anybus X-gateway PROFIBUS-to-EtherNet/IP. These gateways perform real-time protocol conversion, bridging legacy PROFIBUS DP segments with modern EtherNet/IP or Modbus TCP networks — and each gateway requires a clean, regulated 48 VDC input to maintain conversion accuracy and uptime.

Variable frequency drives (VFDs) and servo amplifiers on the motion layer — including Phoenix Contact AXL E EC AL1 EtherCAT drives or third-party Yaskawa and Danfoss VLT units — report speed, torque, and fault data back through the PROFINET backbone. Edge computing nodes, such as the Phoenix Contact PLCnext Control AXC F 2152, aggregate data from multiple network segments, run local analytics, and push summarised datasets to cloud MES or ERP platforms via MQTT or REST APIs. The QUINT-PS/1AC/48DC/5 ensures that every link in this chain — from the field sensor to the cloud edge node — operates from a power rail that never wavers.

Protocol Fragmentation: Many brownfield plants run mixed PROFIBUS DP and PROFINET segments side by side. Without a stable 48 VDC supply powering the protocol gateways and repeaters, conversion latency increases and frame errors propagate upstream. The QUINT-PS/1AC/48DC/5 eliminates this risk by providing a rock-solid power foundation for every gateway and repeater in the segment.

Data Islands and Blind Spots: Remote I/O cabinets located far from the main control room often suffer from under-specified power supplies that cannot sustain inrush currents during cold starts. The QUINT-PS SFB technology delivers 200% peak current for selective fuse breaking, ensuring remote I/O nodes come online cleanly and join the PROFINET ring without causing network disruption.

Remote Monitoring and Diagnostics: The built-in potential-free relay contact and DC OK signal of the QUINT-PS/1AC/48DC/5 can be wired directly into the PLC digital input or a remote I/O module, enabling the SCADA system to monitor PSU health in real time. Any power fault triggers an alarm in the SCADA historian, allowing maintenance teams to respond before a cabinet outage cascades into a production stoppage.

Production Line Transparency: By powering managed switches that support SNMP and PROFINET diagnostics, the QUINT-PS/1AC/48DC/5 indirectly enables full network topology visibility in tools like Siemens SINEMA or Phoenix Contact FL Network Manager — giving engineers a live map of every connected device, port utilisation, and link status across the factory floor.

System Scalability: As production lines expand, additional QUINT-PS units can be paralleled using the Phoenix Contact QUINT-ORING/24DC/2X10/1X20 redundancy module, creating a fault-tolerant N+1 power architecture that scales with the network without requiring cabinet redesign.

Q1: Does the QUINT-PS/1AC/48DC/5 2866679 support PROFINET and PROFIBUS networks simultaneously? The QUINT-PS/1AC/48DC/5 is a power supply, not a communication device. It provides the 48 VDC power rail that energises PROFINET switches, PROFIBUS repeaters, and protocol gateways simultaneously within the same cabinet. As long as the total load does not exceed 5 A (240 W), it can power multiple network segments concurrently without any protocol conflict.

Q2: How does the SFB technology protect network uptime during a downstream short circuit? Phoenix Contact's SFB (Selective Fuse Breaking) technology delivers up to 200% of rated current (10 A) for 12 ms when a downstream short circuit occurs. This peak current selectively blows the branch fuse protecting the faulted circuit while the QUINT-PS continues supplying all other branches at full rated voltage — preventing a single fault from taking down the entire network segment.

Q3: Can the PSU's DC OK relay be integrated into a SCADA alarm system for remote diagnostics? Yes. The potential-free relay contact (DC OK signal) can be wired to a PLC digital input or a remote I/O module on the PROFINET network. The SCADA system reads this input as a discrete tag and can trigger alarms, log events, or initiate maintenance workflows automatically when the PSU detects an output voltage deviation — enabling true remote diagnostics without a site visit.

Q4: What is the warranty coverage and how is the unit tested before shipment? Every QUINT-PS/1AC/48DC/5 2866679 supplied by NANKMOS carries a 12-month warranty covering manufacturing defects and functional failures under normal operating conditions. Each unit undergoes pre-shipment functional testing — including output voltage verification, load regulation check, and SFB response validation — before dispatch. In-stock units are available for immediate shipment with full documentation.

Quality & Delivery Assurance

Functional InspectionFunctional Inspection

100% tested on professional platforms to ensure stable performance.

Anti-static PackagingAnti-static Packaging

Modules are packed in anti-static bags to prevent electrostatic damage.

Secure Export PackingSecure Export Packing

Cushion protection and strong cartons ensure safe transportation.

Worldwide ShippingWorldwide Shipping

Global logistics network supports air, sea and express delivery.

Documentation CheckDocumentation Check

Part number, revision and compatibility verified before shipment.

After-sales SupportAfter-sales Support

Professional technical support to help resolve your issues.

Related Models Often Requested