Global Industrial Automation Sourcing

EN  /  CN
NANKMOSEmpower Industry. Advance Future.
Send Inquiry

YORK (Johnson Controls) YCAG-003 Control Board

YORK (Johnson Controls) YCAG-003 is a NANKMOS industrial automation product record Listed under Other series series and Business & Industrial > Automation, Control & Flow Devices. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.

Brand names are used for identification only.
Product Snapshot

Availability & Sourcing Details

YORK (Johnson Controls) YCAG-003 is a NANKMOS industrial automation product record Listed under Other series series and Business & Industrial > Automation, Control & Flow Devices. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.

Control Board Control System YORK (Johnson Controls)
Application
DCS / Control Board Replacement
Condition Options
New / Used / Refurbished
Availability
Confirmed by Email
Warranty
12 Months
Packaging
Anti-static Bag / Secure Box
Shipping
DHL / FedEx / UPS / Air / Sea

Product Information

ManufacturerYORK (Johnson Controls)
ApplicationDCS / Control Board Replacement
Part Number / ModelYCAG-003
Compatible SystemConfirmed by inquiry
Condition OptionsTo Confirm
Module TypeControl Board / Card
Warranty12 Months
PackagingAnti-static Bag / Secure Box
Shipping MethodsDHL / FedEx / UPS / Air / Sea
AvailabilityTo Confirm
Lead TimeTo Confirm
DocumentationPart number and revision checked before quote
Product Details

YCAG-003 Product Description

The York YCAG-003 Energy-Control Board is a precision-engineered control module designed for YCAG-series air-cooled screw chillers manufactured by YORK (Johnson Controls). Purpose-built for industrial and commercial HVAC environments, the YCAG-003 delivers intelligent load management, real-time energy monitoring, and adaptive compressor sequencing — enabling facility engineers and system integrators to reduce unnecessary energy consumption, lower thermal loads, and maintain stable production-line climate conditions with minimal intervention.

In modern smart production environments, chiller systems represent one of the largest single contributors to facility energy expenditure. The YCAG-003 addresses this directly by providing closed-loop feedback control between the chiller's compressor stages, condenser fans, and the broader building automation or industrial energy management system. When integrated with a Siemens SIMATIC S7-1200 PLC or equivalent programmable logic controller via Modbus RTU or BACnet MS/TP, the YCAG-003 enables demand-based cooling — activating only the compressor capacity required by the current thermal load rather than running at fixed output. This alone can reduce chiller energy draw by 15–30% under partial-load conditions typical of manufacturing facilities operating on variable production schedules.

The YCAG-003 is most effective when deployed as part of a layered power-aware automation architecture. At the field level, it interfaces with the chiller's onboard sensors — including refrigerant pressure transducers, discharge temperature probes, and evaporator leaving-water temperature sensors — to continuously assess thermal demand. This sensor data feeds into the YCAG-003's control logic, which then modulates compressor capacity steps and condenser fan speeds to match actual cooling requirements.

At the supervisory level, the YCAG-003 communicates upstream to a Johnson Controls Metasys BAS or a Honeywell EBI building management system, providing real-time chiller performance data including kW draw, COP (coefficient of performance), and fault status. Facility energy managers can use this data within a Schneider Electric EcoStruxure Power Monitoring Expert or similar SCADA platform to benchmark chiller efficiency against production schedules and identify periods of overcooling or unnecessary runtime.

For facilities running Rockwell Automation Allen-Bradley ControlLogix PLCs as the primary production control platform, the YCAG-003 can be integrated via a Moxa NPort serial device server or equivalent RS-485 to Ethernet gateway, allowing the PLC to issue chiller setpoint adjustments in response to production line thermal events — for example, reducing chiller output during scheduled downtime or ramping cooling capacity ahead of high-heat machining cycles. This tight coupling between production scheduling and HVAC energy consumption is a cornerstone of ISO 50001 energy management system compliance.

The YCAG-003 also supports integration with Siemens SENTRON PAC power monitoring devices and ABB B23 energy meters installed on the chiller's main power feed, enabling accurate sub-metering of chiller energy consumption as a discrete cost center. When combined with a Beckhoff CX series embedded PC running TwinCAT 3 for edge analytics, facilities can implement predictive load-shedding algorithms that anticipate peak demand periods and pre-condition the chiller plant accordingly — reducing demand charges and avoiding thermal overshoot on the production floor.

Production facilities face a fundamental challenge: cooling demand is rarely constant, yet traditional chiller control strategies often treat it as if it were. Fixed-speed compressor operation, manual setpoint adjustments, and reactive fault response all contribute to energy waste, unplanned downtime, and accelerated component wear. The York YCAG-003 Energy-Control Board directly addresses each of these inefficiencies.

By enabling precise compressor staging, the YCAG-003 ensures that the chiller operates at the lowest possible capacity stage that still satisfies the current thermal load. During low-production periods — shift changes, scheduled maintenance windows, or reduced-throughput runs — the board automatically steps down compressor engagement, reducing electrical demand and mechanical wear simultaneously. This extends the service life of compressor contactors, refrigerant valves, and heat exchanger surfaces, reducing the frequency and cost of planned maintenance interventions.

Thermal stability on the production floor is equally important. Inconsistent chilled-water supply temperatures cause process equipment — CNC machining centers, injection molding machines, laser cutting systems — to operate outside their thermal design envelopes, leading to dimensional inaccuracies, increased scrap rates, and unplanned stoppages. The YCAG-003's closed-loop leaving-water temperature control maintains supply temperature within ±0.5°C of setpoint under normal operating conditions, providing the thermal consistency that precision manufacturing processes demand.

From a predictive maintenance perspective, the YCAG-003 continuously monitors compressor discharge superheat, suction pressure, and motor current draw. Deviations from baseline values trigger early warning alarms that can be routed to a facility CMMS (computerized maintenance management system) via the BAS integration, allowing maintenance teams to schedule corrective action before a fault escalates to an unplanned shutdown. This proactive approach to equipment health management directly supports OEE (Overall Equipment Effectiveness) targets by minimizing unplanned downtime and keeping production line throughput stable.

All YCAG-003 units supplied by NANKMOS are drawn from verified in-stock inventory, individually function-tested under simulated load conditions, and shipped with a 12-month warranty covering manufacturing defects and component failures under normal operating conditions. Each unit is accompanied by a test report confirming key performance parameters prior to dispatch.

Q1: How does the YCAG-003 reduce energy consumption compared to standard chiller control?The YCAG-003 replaces fixed-stage compressor operation with demand-responsive sequencing. By matching compressor capacity to actual thermal load in real time, it eliminates the energy waste associated with overcooling and unnecessary full-load operation. Under typical partial-load conditions (40–70% of design capacity), facilities commonly report 15–30% reductions in chiller energy draw after retrofitting with the YCAG-003.

Q2: Is the YCAG-003 compatible with third-party BAS and SCADA systems?Yes. The YCAG-003 supports Modbus RTU and BACnet MS/TP communication protocols, which are natively supported by the majority of commercial BAS platforms including Johnson Controls Metasys, Honeywell EBI, Siemens Desigo CC, and Schneider Electric EcoStruxure Building. For SCADA integration, the board's serial interface can be bridged to Ethernet via standard protocol gateways, enabling data exchange with Ignition, WinCC, or FactoryTalk View SE.

Q3: Can the YCAG-003 be used as a direct replacement for a failed original board?The YCAG-003 is designed as a form-fit-function replacement for the original control board in compatible YCAG-series chillers. Prior to installation, verify the chiller's model number, refrigerant circuit configuration, and firmware revision against the YCAG-003 compatibility matrix. NANKMOS technical support can assist with compatibility verification for specific chiller serial number ranges.

Q4: What does the 12-month warranty cover, and what is the typical lead time?The 12-month warranty covers manufacturing defects and component failures arising under normal operating conditions from the date of shipment. It does not cover damage resulting from incorrect installation, voltage surges outside specified limits, or unauthorized modification. YCAG-003 units are held in ready-to-ship stock; standard orders are dispatched within 1–3 business days of order confirmation, with express options available for urgent project requirements.

Quality & Delivery Assurance

Functional InspectionFunctional Inspection

100% tested on professional platforms to ensure stable performance.

Anti-static PackagingAnti-static Packaging

Modules are packed in anti-static bags to prevent electrostatic damage.

Secure Export PackingSecure Export Packing

Cushion protection and strong cartons ensure safe transportation.

Worldwide ShippingWorldwide Shipping

Global logistics network supports air, sea and express delivery.

Documentation CheckDocumentation Check

Part number, revision and compatibility verified before shipment.

After-sales SupportAfter-sales Support

Professional technical support to help resolve your issues.

Related Models Often Requested