Global Industrial Automation Sourcing

EN  /  CN
NANKMOSEmpower Industry. Advance Future.
Send Inquiry

Allen-Bradley 1768-ENBT EtherNet/IP Bridge Module

Allen-Bradley 1768-ENBT is a NANKMOS industrial automation product record. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.

Brand names are used for identification only.
Product Snapshot

Availability & Sourcing Details

Allen-Bradley 1768-ENBT is a NANKMOS industrial automation product record. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.

Network Module Control System CompactLogix Allen-Bradley
Application
Industrial Network Communication
Condition Options
New / Used / Refurbished
Availability
Confirmed by Email
Warranty
12 Months
Packaging
Anti-static Bag / Secure Box
Shipping
DHL / FedEx / UPS / Air / Sea

Product Information

ManufacturerAllen-Bradley
ApplicationIndustrial Network Communication
Part Number / Model1768-ENBT
Compatible SystemCompactLogix
SeriesCompactLogix
Condition OptionsTo Confirm
Module TypeCommunication Module
Warranty12 Months
PackagingAnti-static Bag / Secure Box
Shipping MethodsDHL / FedEx / UPS / Air / Sea
AvailabilityTo Confirm
Lead TimeTo Confirm
DocumentationPart number and revision checked before quote
Product Details

1768-ENBT Product Description

The Allen-Bradley 1768-ENBT is a high-performance EtherNet/IP Bridge Module engineered for CompactLogix control platforms, delivering seamless industrial network connectivity across the full spectrum of smart factory data infrastructure. Designed to bridge the gap between field-level devices and upper-layer control systems, the 1768-ENBT enables real-time data exchange, deterministic protocol communication, and robust remote diagnostics across distributed automation architectures. Whether integrating PLCs, remote I/O racks, HMI panels, SCADA servers, or edge gateways, this module serves as a critical data link node in any modern industrial connectivity strategy.

In smart manufacturing environments, data latency and protocol fragmentation are among the most persistent barriers to operational transparency. The 1768-ENBT addresses these challenges by providing a dedicated EtherNet/IP communication path directly within the CompactLogix backplane, eliminating the need for external protocol converters and reducing network hop counts between the controller and upstream systems. Its native integration with Rockwell Automation's Logix architecture ensures that tag-based data from field sensors, variable frequency drives, and remote I/O modules flows continuously and reliably to SCADA and MES layers without data loss or conversion overhead.

From signal acquisition at the sensor level through to data visualization on operator workstations, the 1768-ENBT occupies a pivotal position in the industrial data chain. Field instruments — including pressure transmitters, flow meters, and temperature sensors — feed analog and digital signals into remote I/O modules such as the 1734 POINT I/O series, which in turn communicate upstream through the CompactLogix backplane. The 1768-ENBT bridges this backplane data onto the plant Ethernet network, where it becomes accessible to FactoryTalk View SE HMI stations, FactoryTalk Historian servers, and third-party SCADA platforms via standard EtherNet/IP or OPC-DA/UA interfaces.

Variable frequency drives — including Allen-Bradley PowerFlex 525 and PowerFlex 755 series — connected via EtherNet/IP report real-time speed references, torque feedback, fault codes, and energy consumption data through the same network path managed by the 1768-ENBT. This unified data flow enables predictive maintenance algorithms to detect drive anomalies before they escalate into unplanned downtime, with alarm events automatically propagated to SCADA dashboards and mobile notification systems.

For distributed plant topologies, the 1768-ENBT supports integration with industrial managed switches such as the Stratix 5700 series, enabling VLAN segmentation, Quality of Service (QoS) prioritization, and ring redundancy configurations that protect critical control traffic from network congestion. When paired with edge computing gateways — such as the Allen-Bradley Logix Edge or third-party IIoT gateways — the module's EtherNet/IP data stream can be published to cloud analytics platforms, enabling remote performance monitoring, KPI dashboards, and AI-driven process optimization without disrupting real-time control loops.

The 1768-ENBT also plays a key role in remote diagnostics workflows. Maintenance engineers can access live controller tags, I/O status, and network health metrics through RSLinx Classic or Studio 5000 Logix Designer over the plant Ethernet backbone, eliminating the need for on-site intervention for routine diagnostics. Integration with FactoryTalk AssetCentre further enables automated change detection, firmware audit trails, and disaster recovery backups — all routed through the EtherNet/IP infrastructure anchored by the 1768-ENBT.

In multi-controller architectures, the 1768-ENBT supports produced/consumed tag relationships between CompactLogix and ControlLogix platforms, enabling peer-to-peer data sharing across production zones without SCADA intermediation. This capability is essential for coordinated motion control, interlocked safety systems, and cross-zone material tracking in high-throughput manufacturing lines.

Every 1768-ENBT unit supplied by NANKMOS undergoes pre-shipment functional testing, including EtherNet/IP communication verification, backplane interface validation, and network connectivity checks. Units are shipped with a 12-month warranty covering hardware defects and communication failures, supported by in-stock availability for rapid global deployment.

A typical smart factory deployment built around the 1768-ENBT begins at the field device layer, where sensors — including Rockwell Automation 1734-IE4C analog input modules and 1734-OB8 digital output modules from the POINT I/O series — collect process variables such as temperature, pressure, flow rate, and discrete equipment states. These signals are aggregated within the CompactLogix backplane and made available to the controller's tag database, which the 1768-ENBT then publishes onto the plant Ethernet network via EtherNet/IP messaging.

At the drive layer, Allen-Bradley PowerFlex 525 compact AC drives and PowerFlex 755 high-performance drives communicate speed commands, current draw, fault diagnostics, and energy data directly over EtherNet/IP, with the 1768-ENBT serving as the network bridge that routes this data to both the local CompactLogix controller and upstream SCADA systems. Simultaneously, safety I/O modules such as the 1791DS-IB8XOBV4 GuardLogix safety remote I/O transmit safety state data through the same EtherNet/IP fabric, ensuring that safety-critical signals are visible to both the controller and the plant historian.

At the network infrastructure layer, Stratix 5700 managed industrial Ethernet switches provide VLAN segmentation between control traffic and information traffic, with QoS policies ensuring that EtherNet/IP I/O data from the 1768-ENBT receives priority bandwidth allocation over non-critical traffic. Ring topology configurations using DLR (Device Level Ring) protocol provide sub-millisecond failover, maintaining continuous data flow even during cable or switch failures.

HMI stations running FactoryTalk View SE subscribe to live tag data from the CompactLogix controller via the 1768-ENBT's EtherNet/IP connection, displaying real-time process graphics, alarm banners, and trend charts to operators on the plant floor. At the SCADA layer, FactoryTalk Historian SE collects time-stamped process data at configurable scan rates, feeding analytics dashboards and OEE reporting tools. For IIoT-enabled sites, edge gateways aggregate EtherNet/IP data from multiple CompactLogix controllers and publish normalized data streams to cloud platforms via MQTT or REST APIs, enabling enterprise-wide visibility and AI-driven optimization.

Industrial automation sites frequently suffer from protocol fragmentation — legacy serial devices running Modbus RTU or DF1 alongside modern EtherNet/IP controllers create data silos that prevent unified monitoring and control. The 1768-ENBT resolves this by providing a standardized EtherNet/IP gateway within the CompactLogix platform, allowing protocol translation modules such as the 1761-NET-ENI or third-party Modbus-to-EtherNet/IP gateways to feed legacy device data into the same network fabric, eliminating isolated data islands.

Remote monitoring gaps are addressed through the 1768-ENBT's support for RSLinx Enterprise and FactoryTalk Remote Access, enabling maintenance teams to connect to live controller data from off-site locations without VPN complexity. Alarm tracking is enhanced by the module's integration with FactoryTalk Alarms and Events, which captures, timestamps, and routes alarm notifications from field devices through the EtherNet/IP network to operator workstations and mobile devices.

Production line transparency — a key requirement for lean manufacturing and OEE improvement — is achieved by enabling continuous data flow from every connected device through the 1768-ENBT to historian and analytics platforms. System expansion is simplified by the module's support for dynamic tag addressing and CIP routing, allowing new devices and I/O modules to be added to the network without reconfiguring existing communication paths.

Q: What is the communication latency of the 1768-ENBT on an EtherNet/IP network? A: The 1768-ENBT supports Requested Packet Intervals (RPI) as low as 1 ms for I/O connections, providing deterministic, low-latency data exchange suitable for real-time control applications. Actual latency depends on network topology, switch configuration, and the number of active connections.

Q: Is the 1768-ENBT compatible with third-party SCADA and HMI systems? A: Yes. The 1768-ENBT communicates via standard EtherNet/IP (CIP) protocol, which is supported by OPC-DA and OPC-UA servers including Kepware KEPServerEX and Matrikon OPC. This enables integration with any SCADA or HMI platform that supports OPC connectivity, including Wonderware, Ignition, and Siemens WinCC.

Q: Can the 1768-ENBT support network redundancy for high-availability applications? A: The 1768-ENBT supports Device Level Ring (DLR) topology when used with DLR-capable managed switches such as the Stratix 5700, providing sub-millisecond failover for ring network configurations. For higher-level redundancy, it can be deployed in conjunction with redundant CompactLogix controller pairs.

Q: What warranty and pre-shipment testing does NANKMOS provide for the 1768-ENBT? A: Every 1768-ENBT unit is covered by a 12-month hardware warranty from the date of shipment. Prior to dispatch, each unit undergoes pre-shipment functional testing including EtherNet/IP communication verification, backplane interface validation, and network connectivity confirmation. In-stock units are available for immediate global shipping.

Quality & Delivery Assurance

Functional InspectionFunctional Inspection

100% tested on professional platforms to ensure stable performance.

Anti-static PackagingAnti-static Packaging

Modules are packed in anti-static bags to prevent electrostatic damage.

Secure Export PackingSecure Export Packing

Cushion protection and strong cartons ensure safe transportation.

Worldwide ShippingWorldwide Shipping

Global logistics network supports air, sea and express delivery.

Documentation CheckDocumentation Check

Part number, revision and compatibility verified before shipment.

After-sales SupportAfter-sales Support

Professional technical support to help resolve your issues.

Related Models Often Requested

View More Related Models