Allen-Bradley 1771-OG Digital Output Module

Allen-Bradley 1771-OG is a NANKMOS industrial automation product record. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.

Brand names are used for identification only.
Product Snapshot

Availability & Sourcing Details

Allen-Bradley 1771-OG is a NANKMOS industrial automation product record. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.

Controller Module PLC System PLC-5 Allen-Bradley
Application
Controller Processing & System Control
Condition Options
New / Used / Refurbished
Availability
Confirmed by Email
Warranty
12 Months
Packaging
Anti-static Bag / Secure Box
Shipping
DHL / FedEx / UPS / Air / Sea

Product Information

ManufacturerAllen-Bradley
ApplicationController Processing & System Control
Part Number / Model1771-OG
Compatible SystemPLC-5
SeriesPLC-5
Condition OptionsTo Confirm
Module TypeController / CPU Module
Warranty12 Months
PackagingAnti-static Bag / Secure Box
Shipping MethodsDHL / FedEx / UPS / Air / Sea
AvailabilityTo Confirm
Lead TimeTo Confirm
DocumentationPart number and revision checked before quote
Product Details

1771-OG Product Description

The Allen-Bradley 1771-OG is an 8-point, 120V AC digital output module engineered for the PLC-5 rack-based control architecture. Designed to bridge field-level actuators and the PLC-5 processor backplane, this module serves as a critical node in the industrial data chain — converting discrete control signals from the controller into reliable AC switching commands for motors, solenoids, contactors, and indicator systems across manufacturing, energy, and process automation environments.

In a connected factory architecture, the 1771-OG operates within the 1771 I/O chassis alongside complementary modules such as the 1771-IA (120V AC input module) and 1771-IB (24V DC input module), forming a tightly integrated I/O subsystem that feeds real-time field status back to the PLC-5 processor. The processor, in turn, communicates upstream via Data Highway Plus (DH+) or Remote I/O (RIO) networks, enabling SCADA systems and HMI terminals — including PanelView 1000 and PanelView Plus series — to visualize output states, log switching events, and trigger alarm responses without manual intervention.

When deployed in multi-rack or remote I/O configurations, the 1771-OG chassis can be linked through the 1771-ASB Remote I/O Adapter, extending the PLC-5 control domain across plant floors without additional processor hardware. This architecture supports real-time data flow from field devices through the I/O backplane, across the RIO network, and into the PLC-5 data table — where values are accessible to SCADA platforms such as FactoryTalk View SE or third-party OPC-DA/UA servers for enterprise-level data aggregation and visualization.

For facilities integrating legacy PLC-5 systems with modern Ethernet-based infrastructure, the 1771-OG pairs effectively with protocol gateway solutions such as the ProSoft Technology MVI56-DFNT or similar EtherNet/IP-to-RIO bridges, allowing output control commands to originate from ControlLogix or CompactLogix controllers while maintaining backward compatibility with existing 1771 I/O wiring. This hybrid topology is widely adopted in phased modernization projects where full system replacement is not immediately feasible.

The module's 8-point output capacity supports high-density control panel designs, reducing cabinet footprint while maintaining full isolation between output channels. Each output is individually fused and rated for 2A continuous load, making it suitable for driving inductive loads such as motor starters and pneumatic valve solenoids. Output status is indicated via front-panel LEDs, providing local diagnostic visibility that complements remote monitoring data available through the PLC-5 data table.

In smart factory deployments, the 1771-OG contributes to the broader OT data layer by providing deterministic, scan-cycle-synchronized output switching that aligns with PLC-5 ladder logic execution. This determinism is essential for coordinating multi-axis motion sequences, conveyor interlocks, and batch process control steps where output timing directly impacts product quality and throughput. Integration with historian platforms via OPC servers enables long-term output event logging for predictive maintenance analysis and regulatory compliance reporting.

The 1771-OG sits at the field output layer of a multi-tier industrial data architecture. At the base layer, field devices — including proximity sensors, photoelectric sensors, and pressure transmitters — feed status signals into 1771-IA or 1771-IB input modules housed in the same 1771 I/O chassis. The PLC-5 processor reads these inputs on each scan cycle and executes ladder logic to determine output states, which are then written to the 1771-OG output module to drive actuators in real time.

At the network layer, the PLC-5 processor communicates with remote I/O drops via the 1771-ASB adapter, extending control to distributed 1771 I/O racks located at remote machine stations or junction boxes. Simultaneously, the DH+ network connects the PLC-5 to programming terminals, HMI panels such as the PanelView 1400e, and peer PLC-5 controllers in multi-processor architectures. This peer-to-peer messaging capability enables coordinated output control across multiple production zones without centralized bottlenecks.

At the supervisory layer, SCADA platforms access PLC-5 data tables via OPC servers or direct DH+ gateway connections, pulling output status, fault flags, and runtime counters for display on operator workstations. Alarm management systems monitor output state changes and generate notifications when actuators fail to respond within expected timeframes — a capability that depends on the deterministic output switching provided by the 1771-OG. For facilities adopting edge computing architectures, edge gateways equipped with DH+ or RIO interfaces can aggregate output event data locally before forwarding summarized datasets to cloud-based MES or ERP platforms.

In modernization scenarios, the 1771-OG rack integrates with ControlLogix systems through 1756-DHRIO or 1756-RIO bridge modules, allowing newer controllers to manage legacy 1771 I/O without rewiring. This approach preserves existing field wiring investments while enabling EtherNet/IP-based communication to FactoryTalk AssetCentre for asset management and remote firmware diagnostics.

Many industrial facilities operating PLC-5-based systems face persistent challenges around data visibility, protocol fragmentation, and remote monitoring limitations. The 1771-OG addresses several of these gaps directly within its operational context.

Protocol Fragmentation: Sites running mixed Allen-Bradley and third-party equipment often struggle with protocol incompatibility between legacy RIO networks and modern EtherNet/IP infrastructure. By maintaining the 1771-OG within a properly configured RIO network and bridging to EtherNet/IP via gateway modules, operators can unify data flows without replacing field wiring or I/O hardware.

Data Silos: Output event data trapped within the PLC-5 data table becomes accessible to enterprise systems when OPC-UA servers or FactoryTalk Historian are configured to poll the processor. This transforms isolated output switching events into timestamped production records that support OEE analysis and downtime reporting.

Remote Monitoring Limitations: Without remote visibility into output states, maintenance teams must physically inspect panels to diagnose actuator faults. With SCADA integration via DH+ or RIO gateways, output status is continuously streamed to operator workstations, enabling remote fault identification and reducing mean time to repair (MTTR).

Production Line Transparency: By logging output switching sequences through historian platforms, production engineers gain insight into cycle time variability, actuator wear patterns, and process deviations — enabling proactive maintenance scheduling and continuous improvement initiatives.

System Scalability: The 1771 I/O chassis architecture supports expansion by adding output modules to available slots, and remote I/O drops can be added to the RIO network without modifying the PLC-5 program structure, providing a scalable path for production line expansion.

Q1: What communication protocols does the 1771-OG support for SCADA integration?The 1771-OG communicates via the 1771 I/O backplane bus to the PLC-5 processor, which supports Data Highway Plus (DH+) and Remote I/O (RIO) network protocols. SCADA integration is achieved through OPC-DA or OPC-UA servers connected to the PLC-5 via DH+ gateways, or through direct FactoryTalk View SE connections, enabling real-time output state monitoring and alarm management.

Q2: Is the 1771-OG compatible with ControlLogix or CompactLogix systems?The 1771-OG is natively designed for PLC-5 rack systems. Integration with ControlLogix or CompactLogix is possible through 1756-DHRIO or 1756-RIO bridge modules, which allow newer controllers to communicate with legacy 1771 I/O racks over the RIO network. This approach supports phased modernization without full system replacement.

Q3: How does the 1771-OG support remote diagnostics and network stability?Output status for each of the 8 points is reflected in the PLC-5 output data table and accessible via DH+ or RIO network connections. SCADA systems and HMI terminals can continuously poll this data to detect output faults, communication timeouts, or unexpected state changes. Front-panel LEDs provide local status indication for on-site technicians, complementing remote monitoring capabilities.

Q4: What warranty and stock availability does NANKMOS provide for the 1771-OG?NANKMOS supplies the Allen-Bradley 1771-OG with a 12-month warranty covering manufacturing defects and operational failures under normal industrial use conditions. Units are verified through outgoing functional testing prior to shipment. Stock is maintained for immediate dispatch, with global shipping available. For volume pricing or lead time confirmation, contact [email protected] or call +86 18359268345.

Quality & Delivery Assurance

Functional InspectionFunctional Inspection

100% tested on professional platforms to ensure stable performance.

Anti-static PackagingAnti-static Packaging

Modules are packed in anti-static bags to prevent electrostatic damage.

Secure Export PackingSecure Export Packing

Cushion protection and strong cartons ensure safe transportation.

Worldwide ShippingWorldwide Shipping

Global logistics network supports air, sea and express delivery.

Documentation CheckDocumentation Check

Part number, revision and compatibility verified before shipment.

After-sales SupportAfter-sales Support

Professional technical support to help resolve your issues.

Related Models Often Requested