Global Industrial Automation Sourcing

EN  /  CN
NANKMOSEmpower Industry. Advance Future.
Send Inquiry

Allen-Bradley 2093-ASP06 Shunt Module

Allen-Bradley 2093-ASP06 is a NANKMOS industrial automation product record. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.

Brand names are used for identification only.
Product Snapshot

Availability & Sourcing Details

Allen-Bradley 2093-ASP06 is a NANKMOS industrial automation product record. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.

Drive Module Drive System Kinetix Allen-Bradley
Application
Motion Control & Drive System
Condition Options
New / Used / Refurbished
Availability
Confirmed by Email
Warranty
12 Months
Packaging
Anti-static Bag / Secure Box
Shipping
DHL / FedEx / UPS / Air / Sea

Product Information

ManufacturerAllen-Bradley
ApplicationMotion Control & Drive System
Part Number / Model2093-ASP06
Compatible SystemKinetix
SeriesKinetix
Condition OptionsTo Confirm
Module TypeServo / Drive Module
Warranty12 Months
PackagingAnti-static Bag / Secure Box
Shipping MethodsDHL / FedEx / UPS / Air / Sea
AvailabilityTo Confirm
Lead TimeTo Confirm
DocumentationPart number and revision checked before quote
Product Details

2093-ASP06 Product Description

The Allen-Bradley 2093-ASP06 is a precision-engineered shunt module designed for the Kinetix 2000 multi-axis servo drive system, delivering reliable regenerative energy dissipation and seamless integration into modern industrial data networks. In smart factory environments where every node on the automation backbone must communicate, respond, and self-report, the 2093-ASP06 plays a critical role in maintaining drive system stability while supporting the broader data flow architecture that connects field devices to supervisory control layers.

Deployed alongside Kinetix 2000 servo drives in high-cycle motion control applications — including CNC machining centers, packaging lines, and precision assembly systems — the 2093-ASP06 ensures that excess bus voltage generated during motor deceleration is safely absorbed and dissipated. This protects the entire drive network from overvoltage faults that would otherwise interrupt production and trigger unplanned downtime events logged across SCADA dashboards.

In a fully networked Kinetix 2000 motion control cell, the 2093-ASP06 shunt module operates as an integral component of the shared DC bus architecture. The Kinetix 2000 axis modules — such as the 2093-AM01 and 2093-AM02 — draw power from a common bus supplied by the 2093-AC05-MP1 power rail, while the 2093-ASP06 continuously monitors bus voltage levels and activates its internal resistor network to clamp regenerative energy spikes during rapid deceleration cycles.

This real-time energy management function is transparent to the EtherNet/IP network layer, where a ControlLogix L7x controller running Studio 5000 Logix Designer orchestrates all axis motion profiles. The controller communicates drive status, fault codes, and diagnostic data upstream to a FactoryTalk View SE SCADA server, where operators monitor axis health, bus voltage trends, and shunt activation frequency through live HMI dashboards on PanelView Plus 7 terminals.

Upstream from the servo drive cell, a Stratix 5700 managed industrial Ethernet switch aggregates EtherNet/IP traffic from multiple motion control nodes, remote I/O racks using 1734 POINT I/O modules, and safety controllers. The switch forwards real-time data to the plant-level SCADA system, where FactoryTalk Historian captures time-series drive performance data for trend analysis and predictive maintenance workflows. When the 2093-ASP06 shunt module logs an overvoltage event, the fault propagates through the EtherNet/IP network to the ControlLogix controller, which triggers an alarm in FactoryTalk Alarms and Events and notifies maintenance personnel via the plant's remote diagnostic portal.

For facilities integrating variable frequency drives alongside servo systems, the PowerFlex 755 drives on adjacent conveyor and pump circuits share the same Stratix-managed network, enabling unified drive health monitoring across both servo and AC drive platforms from a single FactoryTalk View dashboard. Edge gateway devices — such as the Rockwell Automation FactoryTalk Edge Gateway — collect OPC-UA data from the Kinetix 2000 system and forward it to cloud-based analytics platforms for long-cycle performance benchmarking and remote diagnostics accessible by engineering teams off-site.

Many industrial facilities operating legacy servo drive systems face a common challenge: the physical drive hardware performs reliably, but the data it generates remains invisible to plant-level monitoring systems. The Kinetix 2000 platform, with the 2093-ASP06 shunt module properly installed and configured, addresses this gap by ensuring that bus voltage events, shunt activation cycles, and drive fault histories are captured and surfaced through the EtherNet/IP network to connected SCADA and historian systems.

Sites transitioning from isolated drive cells to fully networked smart factory architectures benefit from the Kinetix 2000's native integration with Studio 5000 Logix Designer and FactoryTalk software suite. Rather than relying on manual inspection of drive status LEDs or periodic maintenance checks, plant engineers can configure real-time alarm thresholds for bus overvoltage events, track shunt activation frequency as a leading indicator of mechanical load changes, and correlate drive fault data with upstream process variables captured by 1756 ControlLogix I/O modules.

Protocol fragmentation — where servo drives, PLCs, remote I/O, and HMI systems speak different communication languages — is eliminated within the Kinetix 2000 ecosystem through consistent EtherNet/IP implementation across all Rockwell Automation components. This unified protocol layer reduces integration engineering time, simplifies network troubleshooting, and enables seamless system expansion by adding additional Kinetix 2000 axis modules or upgrading to Kinetix 5700 drives without redesigning the network architecture.

Q1: Does the 2093-ASP06 support direct EtherNet/IP communication for remote diagnostics? The 2093-ASP06 shunt module itself does not have an independent EtherNet/IP node address. It operates as a passive component on the Kinetix 2000 shared DC bus. Drive system diagnostics, including bus voltage monitoring and fault logging, are managed by the Kinetix 2000 axis modules and reported to the ControlLogix controller via the integrated motion network, which then makes this data available across EtherNet/IP to SCADA and HMI systems.

Q2: Is the 2093-ASP06 compatible with Studio 5000 Logix Designer for configuration? Yes. The Kinetix 2000 drive system, including shunt module configuration parameters, is managed through Studio 5000 Logix Designer's integrated motion configuration interface. Engineers can set bus overvoltage thresholds, configure shunt activation parameters, and monitor real-time bus voltage data directly within the Logix programming environment without requiring separate configuration software.

Q3: Can the 2093-ASP06 be used in systems with multiple Kinetix 2000 axis modules on a shared bus? Yes. The 2093-ASP06 is specifically designed for multi-axis Kinetix 2000 configurations where regenerative energy from multiple servo axes must be managed collectively. A single 2093-ASP06 can protect a shared DC bus serving multiple 2093-AM01 or 2093-AM02 axis modules, provided the total regenerative power does not exceed the shunt module's rated dissipation capacity. For high-power multi-axis systems, multiple shunt modules may be paralleled on the bus.

Q4: What warranty and testing standards apply to NANKMOS-supplied 2093-ASP06 units? All 2093-ASP06 units supplied by NANKMOS carry a 12-month warranty covering manufacturing defects and functional performance. Each unit undergoes functional verification testing prior to shipment, including DC bus interface continuity checks and shunt resistor network validation. Units are shipped with full traceability documentation and are available from in-stock inventory for dispatch within 1–3 business days globally.

Quality & Delivery Assurance

Functional InspectionFunctional Inspection

100% tested on professional platforms to ensure stable performance.

Anti-static PackagingAnti-static Packaging

Modules are packed in anti-static bags to prevent electrostatic damage.

Secure Export PackingSecure Export Packing

Cushion protection and strong cartons ensure safe transportation.

Worldwide ShippingWorldwide Shipping

Global logistics network supports air, sea and express delivery.

Documentation CheckDocumentation Check

Part number, revision and compatibility verified before shipment.

After-sales SupportAfter-sales Support

Professional technical support to help resolve your issues.

Related Models Often Requested