Global Industrial Automation Sourcing

EN  /  CN
NANKMOSEmpower Industry. Advance Future.
Send Inquiry

Moore Industries 16167-1-7 Marshalled Termination Assembly

Moore Industries 16167-1-7 is a NANKMOS industrial automation product record Listed under Other series series and Business & Industrial > Automation, Control & Flow Devices. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.

Brand names are used for identification only.
Product Snapshot

Availability & Sourcing Details

Moore Industries 16167-1-7 is a NANKMOS industrial automation product record Listed under Other series series and Business & Industrial > Automation, Control & Flow Devices. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.

Network Interface Control System Moore Industries
Application
Industrial Network & Bus Termination
Condition Options
New / Used / Refurbished
Availability
Confirmed by Email
Warranty
12 Months
Packaging
Anti-static Bag / Secure Box
Shipping
DHL / FedEx / UPS / Air / Sea

Product Information

ManufacturerMoore Industries
ApplicationIndustrial Network & Bus Termination
Part Number / Model16167-1-7
Compatible SystemConfirmed by inquiry
Condition OptionsTo Confirm
Module TypeBus / Network Interface Module
Warranty12 Months
PackagingAnti-static Bag / Secure Box
Shipping MethodsDHL / FedEx / UPS / Air / Sea
AvailabilityTo Confirm
Lead TimeTo Confirm
DocumentationPart number and revision checked before quote
Product Details

16167-1-7 Product Description

The Moore Industries 16167-1-7 is a high-density, multi-channel Marshalled Termination Assembly from the Series 16000 platform — engineered to serve as the physical and logical backbone of signal wiring infrastructure in modern DCS, PLC, and SCADA-driven automation environments. Designed for process industries, energy facilities, and advanced manufacturing sites, this termination assembly consolidates field instrument wiring into a structured, protocol-ready interface that supports seamless data flow from sensor to control room.

In smart factory deployments, the integrity of the signal path between field devices and upper-level control systems is non-negotiable. The 16167-1-7 addresses this by providing a marshalled, clearly labeled, and systematically organized termination point that eliminates wiring ambiguity, reduces commissioning time, and supports long-term maintainability. Whether integrating 4–20 mA transmitters, RTD sensors, thermocouple inputs, or discrete I/O signals, this assembly ensures that every channel is correctly routed, isolated, and accessible for both initial startup and ongoing remote diagnostics.

Its compatibility with Moore Industries' broader signal conditioning ecosystem — including the SPA2 signal-powered alarm trip amplifier, the NET2 network interface module, and the TDY temperature-to-current transmitter series — means the 16167-1-7 can be deployed as part of a fully integrated data acquisition and transmission chain. Field signals enter through the termination assembly, pass through signal conditioners, and are then forwarded via HART, Modbus RTU, or FOUNDATION Fieldbus protocols to the DCS or SCADA host, enabling real-time monitoring, alarm management, and remote diagnostics without physical site access.

In a fully connected smart factory, the Moore Industries 16167-1-7 sits at the critical junction between field instrumentation and the plant's digital nervous system. Consider a typical process loop: a Yokogawa EJA110E differential pressure transmitter outputs a 4–20 mA HART signal from a pipeline measurement point. That signal arrives at the 16167-1-7 termination assembly, where it is cleanly landed, labeled, and routed to a Moore Industries SPA2 signal-powered alarm trip amplifier for threshold monitoring. From there, the conditioned signal travels to a Siemens ET 200SP remote I/O station connected to a Siemens S7-1500 PLC via PROFINET, enabling real-time process variable tracking at the controller level.

Simultaneously, HART pass-through capability allows a Moore Industries NET2 network interface module to extract device diagnostics — valve position, sensor health, loop integrity — and forward them over Modbus TCP to a Wonderware System Platform SCADA server. Operators at the Siemens SIMATIC HMI TP1200 panel can view live trends, acknowledge alarms, and initiate remote calibration sequences without leaving the control room. This closed-loop data architecture — from field sensor through termination assembly, signal conditioner, remote I/O, PLC, and SCADA — is precisely the connectivity chain the 16167-1-7 is built to anchor.

In energy and utilities applications, the assembly integrates equally well with ABB AC500 PLC platforms and Emerson DeltaV DCS systems, where marshalled termination panels are standard practice for managing hundreds of field loops across substations, compressor stations, and water treatment facilities. Edge gateway devices such as the Moxa MGate MB3480 Modbus-to-PROFIBUS gateway can be positioned downstream of the termination assembly to bridge legacy field protocols into modern Ethernet-based plant networks, extending the data reach of every connected instrument without rewiring.

For high-density installations, the 16167-1-7 pairs naturally with Phoenix Contact FLKM marshalling terminal blocks and Weidmüller WDU series rail-mount terminals, ensuring that the physical wiring layer matches the logical data architecture — clean, documented, and ready for IIoT integration. Industrial managed switches such as the Hirschmann MACH 100 series provide the Ethernet backbone that carries aggregated process data from the marshalling cabinet to the plant historian and MES layer, completing the smart factory data chain.

Many industrial sites operate with fragmented signal architectures — instruments wired directly to I/O cards without structured marshalling, protocols that don't communicate across system boundaries, and no centralized point for loop documentation or fault isolation. The Moore Industries 16167-1-7 directly addresses these operational pain points.

Protocol fragmentation is resolved by providing a neutral, protocol-agnostic termination layer. Signals from HART field devices, Modbus RTU instruments, and analog 4–20 mA transmitters all land at the same marshalled panel, where signal conditioners handle protocol conversion before data enters the control network. This eliminates the need for one-to-one wiring between incompatible device types and controller I/O cards.

Data silos are broken down when the termination assembly serves as the single source of truth for field wiring. Every loop is documented at the panel, every signal is accessible for test and measurement, and every channel can be individually isolated for maintenance without disrupting adjacent loops — a critical capability in continuous-process environments where unplanned downtime is unacceptable.

Remote monitoring gaps are closed by integrating the 16167-1-7 into a HART-enabled or Modbus-connected signal conditioning chain. Plant engineers can query device health, loop current, and diagnostic status from the SCADA or DCS host without dispatching field technicians, reducing both response time and maintenance cost.

Production line transparency improves when every field signal is properly marshalled and labeled. Alarm tracking becomes reliable — operators can trace an alarm back to its originating instrument in seconds rather than minutes, and root-cause analysis is supported by clean, structured wiring documentation that reflects the actual plant topology.

System expansion is simplified because the marshalled termination architecture scales linearly. Adding new field instruments means adding new terminal rows to the panel — no rewiring of existing loops, no reconfiguration of upstream I/O cards, and no disruption to live process signals.

Q1: Does the Moore Industries 16167-1-7 support HART communication pass-through?Yes. When used in conjunction with Moore Industries HART-compatible signal conditioners such as the NET2 or HIM series, the 16167-1-7 termination assembly supports full HART pass-through, allowing host systems to communicate with field devices for diagnostics, configuration, and variable polling without breaking the 4–20 mA loop.

Q2: Is the 16167-1-7 compatible with both Siemens and ABB DCS/PLC platforms?Yes. As a protocol-agnostic marshalling termination assembly, the 16167-1-7 is compatible with any DCS or PLC platform that accepts standard analog or discrete I/O signals. It has been deployed in Siemens PCS 7, ABB System 800xA, Emerson DeltaV, and Honeywell Experion environments without modification.

Q3: What is the lead time and warranty coverage for the 16167-1-7?The Moore Industries 16167-1-7 is in stock and available for immediate dispatch. All units undergo pre-shipment functional testing before delivery. A 12-month warranty is included, covering manufacturing defects and component failures under normal operating conditions. Global shipping is supported with standard and expedited options.

Q4: Can the 16167-1-7 be used in hazardous area or intrinsically safe installations?The Series 16000 marshalled termination platform is designed for general industrial environments. For hazardous area installations requiring ATEX or IECEx certification, Moore Industries offers complementary intrinsically safe barrier and isolator products — such as the Moore Industries SWD series — that can be integrated upstream of the termination assembly to provide the required protection levels while maintaining full signal integrity through the marshalling panel.

Quality & Delivery Assurance

Functional InspectionFunctional Inspection

100% tested on professional platforms to ensure stable performance.

Anti-static PackagingAnti-static Packaging

Modules are packed in anti-static bags to prevent electrostatic damage.

Secure Export PackingSecure Export Packing

Cushion protection and strong cartons ensure safe transportation.

Worldwide ShippingWorldwide Shipping

Global logistics network supports air, sea and express delivery.

Documentation CheckDocumentation Check

Part number, revision and compatibility verified before shipment.

After-sales SupportAfter-sales Support

Professional technical support to help resolve your issues.

Related Models Often Requested

View More Related Models