Global Industrial Automation Sourcing

EN  /  CN
NANKMOSEmpower Industry. Advance Future.
Send Inquiry

Honeywell 51304260-400 Communication Gateway

Honeywell 51304260-400 is a NANKMOS industrial automation product record Listed under TDC 3000 series and Business & Industrial > Automation, Control & Flow Devices. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.

Brand names are used for identification only.
Product Snapshot

Availability & Sourcing Details

Honeywell 51304260-400 is a NANKMOS industrial automation product record Listed under TDC 3000 series and Business & Industrial > Automation, Control & Flow Devices. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.

Network Module Control System TDC 3000 Honeywell
Application
Industrial Network Communication
Condition Options
New / Used / Refurbished
Availability
Confirmed by Email
Warranty
12 Months
Packaging
Anti-static Bag / Secure Box
Shipping
DHL / FedEx / UPS / Air / Sea

Product Information

ManufacturerHoneywell
ApplicationIndustrial Network Communication
Part Number / Model51304260-400
Compatible SystemTDC 3000
SeriesTDC 3000
Condition OptionsTo Confirm
Module TypeCommunication Module
Warranty12 Months
PackagingAnti-static Bag / Secure Box
Shipping MethodsDHL / FedEx / UPS / Air / Sea
AvailabilityTo Confirm
Lead TimeTo Confirm
DocumentationPart number and revision checked before quote
Product Details

51304260-400 Product Description

The Honeywell 51304260-400 is a high-performance industrial communication gateway engineered for seamless data flow across the full automation hierarchy — from field-level sensors and actuators through PLC controllers, remote I/O modules, HMI panels, SCADA platforms, and enterprise MES systems. Designed as a core connectivity node within the Honeywell TDC 3000 distributed control architecture, this module enables real-time protocol translation, network-level data aggregation, and transparent device integration across heterogeneous industrial environments.

In modern smart factory deployments, data continuity between operational technology (OT) and information technology (IT) layers is critical. The 51304260-400 bridges this gap by supporting multi-protocol communication across Modbus RTU/TCP, HART, Foundation Fieldbus, and proprietary Honeywell network layers, ensuring that every signal — from a pressure transmitter on the process line to a variable frequency drive in the motor control center — is accurately captured, converted, and delivered to the supervisory layer without latency or data loss.

The Honeywell 51304260-400 sits at the heart of a layered industrial data architecture. At the field level, analog and digital signals from Honeywell STT850 Smart Temperature Transmitters and pressure sensors are collected via HART protocol, feeding live process values directly into the gateway's protocol engine. These signals are normalized and forwarded upstream to Honeywell HC900 Hybrid Controllers acting as local PLC nodes, where logic execution and loop control occur in real time.

Simultaneously, the 51304260-400 interfaces with Honeywell Remote I/O (RMIO) modules distributed across the plant floor, consolidating discrete and analog I/O data from multiple field cabinets into a single coherent data stream. This aggregated data is then transmitted over the plant's industrial Ethernet backbone — typically managed through Cisco IE3400 or Hirschmann MACH104 industrial managed switches — ensuring deterministic, low-latency delivery to the supervisory layer.

At the SCADA and HMI level, the gateway communicates natively with Honeywell Experion PKS (Process Knowledge System) servers, enabling operators to visualize real-time process trends, configure alarm thresholds, and execute remote setpoint adjustments from centralized control rooms. For facilities running third-party HMI platforms such as Wonderware InTouch or Ignition SCADA by Inductive Automation, the 51304260-400's Modbus TCP/IP interface provides a universal data bridge, eliminating the need for custom middleware.

Variable frequency drives — including Honeywell SmartVFD HVAC drives — are integrated into the data loop via RS-485 Modbus RTU, with the gateway polling drive status registers (output frequency, motor current, fault codes) at configurable scan rates. This data is surfaced in real time on SCADA dashboards, enabling predictive maintenance workflows and reducing unplanned downtime. Edge computing nodes, such as Honeywell Experion Edge or third-party IIoT gateways, can subscribe to the 51304260-400's data streams via OPC-UA or MQTT forwarding configurations, pushing processed analytics to cloud-based MES or ERP platforms for enterprise-wide visibility.

The complete data chain — from signal acquisition at the sensor, through protocol conversion at the 51304260-400, across the industrial switch fabric, into SCADA visualization, and up to enterprise reporting — forms the backbone of a transparent, connected smart factory. Every node in this chain depends on the reliability and protocol fidelity of the communication gateway at its center.

Protocol Fragmentation: Many legacy automation sites operate with a mix of Modbus RTU, HART, Foundation Fieldbus, and proprietary DCS protocols running in parallel silos. The 51304260-400 resolves this by acting as a unified protocol translator, converting all field-level signals into a single coherent data format consumable by modern SCADA and MES platforms — eliminating the need for multiple standalone converters and reducing wiring complexity.

Data Islands and Blind Spots: Remote I/O cabinets, standalone VFDs, and field-mounted sensors often operate as isolated data islands with no upstream visibility. By integrating these devices into the TDC 3000 network through the 51304260-400, operators gain full process transparency — every device status, alarm event, and performance metric is visible from the central control room in real time.

Remote Monitoring and Diagnostics: Unplanned site visits for fault diagnosis are costly and time-consuming. The 51304260-400 enables remote diagnostic access through SCADA-connected network paths, allowing engineers to interrogate device registers, review communication error logs, and validate signal integrity without physical presence on the plant floor. This capability is especially valuable for geographically distributed facilities or unmanned remote stations.

Production Line Transparency and Alarm Traceability: With all field devices feeding data through a single gateway node, alarm events are timestamped, sequenced, and traceable back to their source device. This supports root cause analysis, regulatory compliance reporting, and continuous process improvement initiatives — transforming raw alarm data into actionable operational intelligence.

System Scalability: As production capacity grows, additional field devices, remote I/O nodes, and communication modules can be integrated into the existing TDC 3000 network without architectural redesign. The 51304260-400's modular communication architecture supports incremental expansion, protecting the initial infrastructure investment while accommodating future automation requirements.

Q1: What communication protocols does the Honeywell 51304260-400 support, and is it compatible with third-party SCADA systems? The 51304260-400 supports Modbus RTU, Modbus TCP/IP, HART, Foundation Fieldbus, and Honeywell's proprietary UCN/LCN network protocols. Its Modbus TCP/IP interface ensures broad compatibility with third-party SCADA platforms including Wonderware, Ignition, and iFIX, making it suitable for both pure Honeywell environments and mixed-vendor automation architectures.

Q2: How does this gateway handle communication latency in high-speed process control applications? The 51304260-400 is designed for deterministic, low-latency data exchange within the TDC 3000 architecture. Cyclic polling intervals are configurable to match process scan requirements, and the module's backplane bus interface minimizes inter-module communication delays. For time-critical loops, it is recommended to pair the gateway with managed industrial switches (e.g., Hirschmann MACH series) configured with QoS prioritization to ensure consistent network performance.

Q3: Can the 51304260-400 be used for remote diagnostics, and what network infrastructure is required? Yes. When integrated into a plant network with Ethernet connectivity to an Experion PKS or compatible SCADA server, the 51304260-400 supports remote register interrogation, communication status monitoring, and fault log retrieval through the SCADA interface. A standard industrial Ethernet infrastructure with appropriate firewall and VPN configuration is sufficient for secure remote access.

Q4: What does the 12-month warranty cover, and how is pre-shipment testing conducted? Every Honeywell 51304260-400 unit supplied by NANKMOS undergoes full functional testing prior to shipment, including communication protocol verification, interface continuity checks, and power-on self-test validation. The 12-month warranty covers manufacturing defects and functional failures under normal operating conditions. Units are shipped with test reports available upon request, and our technical team provides post-sale integration support to ensure successful commissioning.

Quality & Delivery Assurance

Functional InspectionFunctional Inspection

100% tested on professional platforms to ensure stable performance.

Anti-static PackagingAnti-static Packaging

Modules are packed in anti-static bags to prevent electrostatic damage.

Secure Export PackingSecure Export Packing

Cushion protection and strong cartons ensure safe transportation.

Worldwide ShippingWorldwide Shipping

Global logistics network supports air, sea and express delivery.

Documentation CheckDocumentation Check

Part number, revision and compatibility verified before shipment.

After-sales SupportAfter-sales Support

Professional technical support to help resolve your issues.

Related Models Often Requested