Global Industrial Automation Sourcing

EN  /  CN
NANKMOSEmpower Industry. Advance Future.
Send Inquiry

Allen-Bradley 1794-OB16 Digital Output Module

Allen-Bradley 1794-OB16 is a NANKMOS industrial automation product record. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.

Brand names are used for identification only.
Product Snapshot

Availability & Sourcing Details

Allen-Bradley 1794-OB16 is a NANKMOS industrial automation product record. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.

Controller Module PLC System Flex I/O Allen-Bradley
Application
Controller Processing & System Control
Condition Options
New / Used / Refurbished
Availability
Confirmed by Email
Warranty
12 Months
Packaging
Anti-static Bag / Secure Box
Shipping
DHL / FedEx / UPS / Air / Sea

Product Information

ManufacturerAllen-Bradley
ApplicationController Processing & System Control
Part Number / Model1794-OB16
Compatible SystemFlex I/O
SeriesFlex I/O
Condition OptionsTo Confirm
Module TypeController / CPU Module
Warranty12 Months
PackagingAnti-static Bag / Secure Box
Shipping MethodsDHL / FedEx / UPS / Air / Sea
AvailabilityTo Confirm
Lead TimeTo Confirm
DocumentationPart number and revision checked before quote
Product Details

1794-OB16 Product Description

The Allen-Bradley 1794-OB16 is a 16-point, 24VDC digital output module engineered for the FLEX I/O platform — one of Rockwell Automation's most widely deployed distributed I/O architectures in smart manufacturing environments. Designed to operate at the edge of the control network, the 1794-OB16 bridges the gap between field-level actuators and the upper layers of an industrial data chain: from PLC controllers and remote I/O nodes through to HMI panels, SCADA systems, and enterprise-level data visualization platforms. Whether deployed on a DeviceNet segment, a ControlNet backbone, or an EtherNet/IP ring topology, this module delivers deterministic, high-speed output switching that modern connected factories demand.

In a fully connected smart factory, the 1794-OB16 sits at a critical junction in the automation data chain. Signal acquisition begins upstream at the sensor and field device layer — pressure transducers, proximity switches, and photoelectric sensors feed real-time process data into a ControlLogix or CompactLogix PLC via analog and digital input modules such as the 1794-IB16 (16-point digital input) or 1794-IE8 (8-channel analog input). The PLC executes the control logic and issues output commands that travel down the network to the 1794-OB16, which then drives actuators, solenoid valves, motor starters, and indicator lights on the production floor.

Network communication is handled by a FLEX I/O adapter mounted on the same backplane. A 1794-AENT EtherNet/IP adapter, for example, connects the entire FLEX I/O rack — including the 1794-OB16 — to the plant's Ethernet backbone, enabling real-time I/O data exchange with Studio 5000 Logix Designer and upstream SCADA platforms such as FactoryTalk View SE or Ignition SCADA. This architecture supports sub-millisecond scan times and deterministic data delivery, which is essential for high-speed packaging lines, conveyor control, and precision assembly stations.

For installations requiring multi-protocol flexibility, the 1794-OB16 can be paired with a 1794-ADN DeviceNet adapter to integrate with legacy DeviceNet segments, or a 1794-ACN15 ControlNet adapter for time-critical, scheduled data transfers across a ControlNet ring. This makes the module equally at home in greenfield EtherNet/IP plants and brownfield facilities still running DeviceNet or ControlNet infrastructure.

At the HMI layer, operators interact with the system through PanelView Plus terminals or third-party HMI panels connected via EtherNet/IP. Tag data from the 1794-OB16 — output status, fault bits, and diagnostic information — is mapped directly into the HMI project, giving operators real-time visibility into actuator states without requiring additional wiring or protocol converters. Alarm conditions, such as output overcurrent or module fault, are surfaced immediately on the HMI and forwarded to the SCADA historian for trend analysis and root-cause investigation.

Edge gateway devices, such as the Moxa MGate series or Ewon Flexy industrial routers, can be deployed alongside the FLEX I/O rack to extend remote monitoring capabilities to cloud-based MES and ERP platforms. This enables plant managers to track output utilization rates, predictive maintenance indicators, and energy consumption data from any location — a key requirement for IIoT-enabled smart factory programs. Variable frequency drives (VFDs) controlling conveyor motors or pump systems can also receive enable/disable commands from the 1794-OB16, closing the loop between the PLC control layer and the power drive layer in a single, unified data architecture.

Many industrial facilities face persistent challenges around protocol fragmentation, data silos, and limited remote visibility — problems that the 1794-OB16 and the broader FLEX I/O ecosystem are specifically designed to address.

Protocol Fragmentation: Sites running a mix of DeviceNet, ControlNet, and EtherNet/IP networks often struggle to unify I/O data across segments. The FLEX I/O platform resolves this by allowing the same 1794-OB16 module to operate under different adapters — swap the adapter, and the module communicates on a different network — without replacing field wiring or output hardware. This dramatically reduces migration costs when upgrading from legacy DeviceNet to modern EtherNet/IP topologies.

Data Silos and Production Transparency: When output modules operate in isolation without network connectivity, production data remains trapped at the field level. By integrating the 1794-OB16 into an EtherNet/IP network and connecting it to FactoryTalk Historian or a third-party SCADA historian, every output state change is time-stamped and logged — creating a complete audit trail for quality management, OEE analysis, and regulatory compliance.

Remote Monitoring and Diagnostics: Unplanned downtime caused by undetected output faults is a major cost driver in discrete manufacturing. The 1794-OB16 provides module-level diagnostics accessible via the network adapter, allowing maintenance engineers to identify blown fuses, wiring faults, or overloaded outputs remotely — before a line stoppage occurs. Combined with an edge gateway and a cloud dashboard, this capability supports predictive maintenance programs that reduce mean time to repair (MTTR) by up to 40%.

System Scalability: As production lines expand, adding I/O capacity should not require a complete rewiring exercise. The FLEX I/O backplane supports up to eight I/O modules per adapter, and multiple adapters can be networked together on a single EtherNet/IP segment. This modular architecture allows engineers to add 1794-OB16 modules incrementally as new actuator circuits are commissioned, protecting the initial infrastructure investment.

Q1: What communication protocols does the 1794-OB16 support? The 1794-OB16 itself is a pure I/O module with no onboard communication processor. Protocol support is determined by the FLEX I/O adapter installed on the same backplane. Supported adapters include the 1794-AENT (EtherNet/IP), 1794-ADN (DeviceNet), and 1794-ACN15 (ControlNet), giving the module compatibility with all three major Rockwell Automation network protocols.

Q2: How is network stability ensured in high-vibration or electrically noisy environments? The 1794-OB16 is rated for industrial environments with operating temperatures up to 55°C and is designed to meet IEC 61131-2 noise immunity standards. For installations in high-EMI environments — near VFDs, welding equipment, or large motor starters — Rockwell Automation recommends proper cable shielding, grounding practices per the FLEX I/O installation manual, and the use of industrial-grade managed switches such as the Stratix 5700 series to maintain EtherNet/IP network integrity.

Q3: Can the 1794-OB16 be used with non-Rockwell PLCs or SCADA systems? Yes, with the appropriate adapter. When paired with a 1794-AENT EtherNet/IP adapter, the 1794-OB16 can be accessed by any EtherNet/IP-compatible controller or SCADA platform, including Siemens systems with EtherNet/IP scanner capability, Ignition SCADA via the Allen-Bradley EtherNet/IP driver, and third-party OPC-UA gateways that support CIP protocol translation.

Q4: What does the 12-month warranty cover, and how is pre-shipment testing conducted? Every 1794-OB16 unit supplied by NANKMOS carries a 12-month warranty covering manufacturing defects and functional failures under normal operating conditions. Prior to shipment, each module undergoes functional output verification testing to confirm all 16 output channels operate within specification. Units are shipped in anti-static packaging with full traceability documentation. In the event of a warranty claim, NANKMOS provides direct technical support and expedited replacement to minimize production downtime.

Quality & Delivery Assurance

Functional InspectionFunctional Inspection

100% tested on professional platforms to ensure stable performance.

Anti-static PackagingAnti-static Packaging

Modules are packed in anti-static bags to prevent electrostatic damage.

Secure Export PackingSecure Export Packing

Cushion protection and strong cartons ensure safe transportation.

Worldwide ShippingWorldwide Shipping

Global logistics network supports air, sea and express delivery.

Documentation CheckDocumentation Check

Part number, revision and compatibility verified before shipment.

After-sales SupportAfter-sales Support

Professional technical support to help resolve your issues.

Related Models Often Requested

View More Related Models