Global Industrial Automation Sourcing

EN  /  CN
NANKMOSEmpower Industry. Advance Future.
Send Inquiry

Allen-Bradley 1794-OB16PXT Digital Output Module

Allen-Bradley 1794-OB16PXT is a NANKMOS industrial automation product record. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.

Brand names are used for identification only.
Product Snapshot

Availability & Sourcing Details

Allen-Bradley 1794-OB16PXT is a NANKMOS industrial automation product record. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.

Controller Module PLC System Flex I/O Allen-Bradley
Application
Controller Processing & System Control
Condition Options
New / Used / Refurbished
Availability
Confirmed by Email
Warranty
12 Months
Packaging
Anti-static Bag / Secure Box
Shipping
DHL / FedEx / UPS / Air / Sea

Product Information

ManufacturerAllen-Bradley
ApplicationController Processing & System Control
Part Number / Model1794-OB16PXT
Compatible SystemFlex I/O
SeriesFlex I/O
Condition OptionsTo Confirm
Module TypeController / CPU Module
Warranty12 Months
PackagingAnti-static Bag / Secure Box
Shipping MethodsDHL / FedEx / UPS / Air / Sea
AvailabilityTo Confirm
Lead TimeTo Confirm
DocumentationPart number and revision checked before quote
Product Details

1794-OB16PXT Product Description

The Allen-Bradley 1794-OB16PXT is a 16-point 24VDC digital output module engineered for the Flex I/O platform, delivering high-density field-side connectivity across distributed control architectures. Designed to operate within Allen-Bradley's ControlLogix and CompactLogix ecosystems, this module serves as a critical node in the industrial data chain — bridging field-level actuators, solenoids, and motor starters with upper-layer PLC controllers, SCADA systems, and HMI interfaces. Its extended temperature rating and robust I/O density make it a preferred choice for demanding smart factory environments where continuous uptime, real-time data flow, and remote diagnostics are non-negotiable.

In modern industrial connectivity architectures, the 1794-OB16PXT functions as a downstream output node that receives control commands from a ControlLogix L7x or CompactLogix L3x controller via a Flex I/O adapter such as the 1794-AENT (EtherNet/IP) or 1794-ADN (DeviceNet). These adapters translate network-layer protocol packets into module-level I/O commands, enabling the 1794-OB16PXT to actuate field devices with sub-millisecond response times. This tight integration between the network adapter, the output module, and the controller backplane ensures deterministic data delivery — a fundamental requirement for closed-loop automation and real-time process control.

The 1794-OB16PXT sits at the output end of a fully connected smart factory data chain. Signal acquisition begins upstream at field-level sensors and transmitters — such as Allen-Bradley 1734-IE4C analog input modules or 1734-IB8 digital input modules on the POINT I/O platform — which feed real-time process data into a ControlLogix L73 controller via EtherNet/IP. The controller's ladder logic or function block programs evaluate incoming signals, execute control decisions, and dispatch output commands downstream through the 1794-AENT EtherNet/IP adapter to the 1794-OB16PXT, which then drives actuators, solenoids, and relay coils on the factory floor.

For multi-segment plant networks, the 1794-OB16PXT integrates seamlessly into a layered architecture where a Stratix 5700 managed industrial Ethernet switch handles network segmentation, VLAN configuration, and traffic prioritization between the controller subnet and the I/O subnet. This ensures that output command packets from the ControlLogix backplane reach the 1794-OB16PXT with consistent latency, even under high network load conditions. In parallel, a PowerFlex 525 variable frequency drive may receive speed reference commands from the same controller, while the 1794-OB16PXT handles discrete on/off control of auxiliary contactors and pilot lights — both operating on the same EtherNet/IP network segment.

At the SCADA and HMI layer, FactoryTalk View SE or an Ignition SCADA server subscribes to I/O tag data published by the ControlLogix controller, providing operators with real-time visibility into the output states of each of the 16 channels on the 1794-OB16PXT. Alarm conditions — such as output overcurrent or module fault — are automatically propagated from the module's diagnostic registers through the controller tag database to the SCADA alarm management system, enabling rapid fault identification without physical inspection. For remote sites, a 1783-ETAP EtherNet/IP tap or a Cisco IE 4000 industrial router can extend this diagnostic visibility over WAN or cellular links, supporting full remote monitoring and diagnostics from a central operations center.

In edge computing deployments, a Moxa MGate MB3180 protocol gateway or a Kepware KEPServerEX OPC-UA server can bridge the EtherNet/IP data from the 1794-OB16PXT's host controller to cloud-based MES or ERP platforms, enabling production output data to flow from the field device level all the way to enterprise dashboards. This end-to-end data visibility — from the 1794-OB16PXT output channel state to a cloud KPI dashboard — represents the full realization of IIoT-enabled smart factory connectivity.

Many industrial sites operating legacy distributed I/O systems face persistent challenges: protocol fragmentation between older DeviceNet segments and newer EtherNet/IP networks, data silos that prevent SCADA systems from accessing field-level output diagnostics, and limited remote monitoring capability for geographically distributed output nodes. The 1794-OB16PXT, when paired with the appropriate Flex I/O adapter, directly addresses these gaps by supporting multiple network protocols through a single modular platform — allowing engineers to migrate from DeviceNet (via 1794-ADN) to EtherNet/IP (via 1794-AENT) without replacing field wiring or output modules.

For sites struggling with production line transparency, the 1794-OB16PXT's per-channel diagnostic capability enables the controller to detect and report individual output faults — short circuits, open loads, or thermal overloads — directly to the SCADA alarm system. This eliminates the traditional reliance on manual field inspection for fault isolation, reducing mean time to repair (MTTR) and improving overall equipment effectiveness (OEE). In multi-zone production environments, the module's ability to operate across extended temperature ranges ensures reliable output performance in foundry, outdoor, or cold-storage applications where standard I/O modules may fail.

System expansion is equally straightforward: additional 1794-OB16PXT modules can be added to an existing Flex I/O rack without controller reprogramming, as the 1794-AENT adapter automatically detects new modules and updates the I/O configuration map. This plug-and-expand architecture supports phased capacity growth aligned with production scaling requirements, making the 1794-OB16PXT a long-term investment in flexible, scalable smart factory infrastructure.

Q1: What communication protocols does the 1794-OB16PXT support? The 1794-OB16PXT itself is a passive output module; its network protocol support is determined by the Flex I/O adapter installed in the same rack. With the 1794-AENT adapter, it communicates over EtherNet/IP. With the 1794-ADN, it operates on DeviceNet. The 1794-ACN15 enables ControlNet connectivity, and the 1794-APB supports PROFIBUS DP — giving the module broad multi-protocol compatibility within a single hardware platform.

Q2: How does the 1794-OB16PXT support remote diagnostics and fault detection? The module provides per-channel diagnostic data — including output fault status, short-circuit detection, and thermal overload flags — accessible via the controller's I/O tag database. These diagnostics are available in real time to connected SCADA and HMI systems, enabling remote fault identification and alarm generation without requiring physical access to the field panel. This capability is fully supported over EtherNet/IP with the 1794-AENT adapter.

Q3: Is the 1794-OB16PXT compatible with ControlLogix and CompactLogix controllers? Yes. The 1794-OB16PXT is fully compatible with ControlLogix (L6x, L7x, L8x series), CompactLogix (L1x, L2x, L3x series), FlexLogix, and SoftLogix platforms when used with the appropriate Flex I/O network adapter. It is configured and managed through Rockwell Automation's Studio 5000 Logix Designer software, which provides full I/O tree integration, tag mapping, and diagnostic monitoring.

Q4: What warranty and pre-shipment testing does NANKMOS provide for the 1794-OB16PXT? Every 1794-OB16PXT supplied by NANKMOS is covered by a 12-Month Warranty against manufacturing defects and functional failures. Prior to shipment, each unit undergoes functional verification testing to confirm output channel integrity, module communication, and diagnostic register operation. Units are in stock and typically ship within 1–3 business days. For volume orders or urgent project requirements, contact [email protected] or call +86 18359268345 for expedited fulfillment options.

Quality & Delivery Assurance

Functional InspectionFunctional Inspection

100% tested on professional platforms to ensure stable performance.

Anti-static PackagingAnti-static Packaging

Modules are packed in anti-static bags to prevent electrostatic damage.

Secure Export PackingSecure Export Packing

Cushion protection and strong cartons ensure safe transportation.

Worldwide ShippingWorldwide Shipping

Global logistics network supports air, sea and express delivery.

Documentation CheckDocumentation Check

Part number, revision and compatibility verified before shipment.

After-sales SupportAfter-sales Support

Professional technical support to help resolve your issues.

Related Models Often Requested

View More Related Models