Global Industrial Automation Sourcing

EN  /  CN
NANKMOSEmpower Industry. Advance Future.
Send Inquiry

Honeywell 05701-A-0327 Industrial Relay Output Module

Honeywell 05701-A-0327 is a NANKMOS industrial automation product record. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.

Brand names are used for identification only.
Product Snapshot

Availability & Sourcing Details

Honeywell 05701-A-0327 is a NANKMOS industrial automation product record. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.

Controller Module PLC System TDC 3000 Honeywell
Application
Controller Processing & System Control
Condition Options
New / Used / Refurbished
Availability
Confirmed by Email
Warranty
12 Months
Packaging
Anti-static Bag / Secure Box
Shipping
DHL / FedEx / UPS / Air / Sea

Product Information

ManufacturerHoneywell
ApplicationController Processing & System Control
Part Number / Model05701-A-0327
Compatible SystemTDC 3000
SeriesTDC 3000
Condition OptionsTo Confirm
Module TypeController / CPU Module
Warranty12 Months
PackagingAnti-static Bag / Secure Box
Shipping MethodsDHL / FedEx / UPS / Air / Sea
AvailabilityTo Confirm
Lead TimeTo Confirm
DocumentationPart number and revision checked before quote
Product Details

05701-A-0327 Product Description

The Honeywell 05701-A-0327 Double SPCO Relay Output Card is a precision-engineered industrial network interface module designed for the TDC 3000 Distributed Control System (DCS) platform. In modern smart factory environments, reliable relay output and seamless data connectivity between field devices and upper-level control systems are non-negotiable. The 05701-A-0327 serves as a critical node in the industrial data chain — bridging physical process signals with digital control architectures to enable real-time monitoring, remote diagnostics, and transparent production management.

Deployed across process industries including oil and gas, chemical, power generation, and advanced manufacturing, this relay card integrates directly into the TDC 3000 control highway, ensuring deterministic signal switching and stable network communication. Its double SPCO (Single Pole Change Over) relay configuration provides flexible output routing for actuators, solenoid valves, alarm annunciators, and interlock systems — all while maintaining the data integrity required by SCADA and HMI supervisory layers.

In a fully connected smart factory, the 05701-A-0327 operates at the intersection of physical process control and digital data infrastructure. Signal acquisition begins at the field level, where sensors — including pressure transmitters, temperature elements, and flow meters — feed analog and discrete signals into Honeywell TDC 3000 Field Control Processors (FCP) and Process Manager (PM) modules. These controllers process the incoming data and issue relay output commands through the 05701-A-0327, which then actuates downstream devices such as solenoid valves, motor starters, and alarm panels.

Within the TDC 3000 architecture, the relay card communicates over the Local Control Network (LCN) and Universal Control Network (UCN), enabling real-time data exchange with the Honeywell Application Module (AM) and History Module (HM). This data pathway supports continuous process variable logging, event-driven alarm generation, and batch reporting — all essential for SCADA transparency and regulatory compliance.

At the supervisory layer, Honeywell's HMIWeb Display Builder and Experion PKS SCADA platform receive structured data from the TDC 3000 network, providing operators with real-time dashboards, trend visualization, and alarm management. The 05701-A-0327 relay outputs are mapped as discrete status points within these HMI screens, enabling operators to monitor actuator states, interlock conditions, and relay health from a centralized control room.

For remote diagnostics and predictive maintenance, the TDC 3000 system's data highway connects to edge gateway devices — such as Honeywell's Control Data Access (CDA) server or third-party OPC-UA gateways — which translate proprietary LCN/UCN protocol data into standard industrial formats compatible with MES and ERP systems. This integration allows maintenance engineers to remotely query relay output status, review historical switching events, and identify potential failure patterns before unplanned downtime occurs.

In multi-loop control architectures, the 05701-A-0327 works alongside Honeywell TDC 3000 Analog Output Modules (such as the 05701-A-0322 series), Digital Input Modules, and Communication Gateway Modules to form a complete I/O subsystem. Power distribution to the card chassis is managed by Honeywell TDC 3000 Power Supply Modules, ensuring stable 24VDC rail voltage across all installed cards. Industrial Ethernet switches at the network backbone layer provide the physical connectivity between control room servers, engineering workstations, and remote I/O panels — completing the end-to-end data chain from field device to enterprise system.

Legacy DCS environments often suffer from protocol fragmentation, data silos, and limited remote visibility — challenges that directly impact production efficiency and maintenance responsiveness. The Honeywell 05701-A-0327, as part of the TDC 3000 ecosystem, addresses these gaps through a structured approach to industrial connectivity:

Protocol Unification: The TDC 3000 LCN/UCN architecture provides a unified communication backbone across all I/O modules, eliminating the need for ad-hoc protocol converters between relay output cards and the control system. This reduces configuration complexity and minimizes communication latency in time-critical interlock applications.

Eliminating Data Silos: By integrating relay output status directly into the TDC 3000 data highway, the 05701-A-0327 ensures that all switching events are captured in the History Module and made available to SCADA and MES layers. Operators gain full production line transparency — from individual relay state to system-wide process trends — without manual data reconciliation.

Remote Monitoring and Diagnostics: Through OPC-DA/OPC-UA gateway integration, relay output data from the 05701-A-0327 can be accessed remotely by maintenance teams using standard industrial diagnostic tools. This capability supports condition-based maintenance strategies, reducing the need for on-site inspections and enabling faster fault isolation.

Alarm Tracking and Escalation: The TDC 3000 alarm management framework captures relay output state changes as discrete alarm events, with configurable priority levels and escalation paths. This ensures that critical process deviations — such as unexpected relay de-energization or interlock activation — are immediately visible to operators and logged for post-incident analysis.

System Scalability: The modular card-slot architecture of the TDC 3000 chassis allows additional relay output cards to be added as production requirements grow, without disrupting existing network configurations. This scalability supports phased smart factory upgrades and greenfield expansion projects alike.

Q1: What communication protocol does the Honeywell 05701-A-0327 use, and is it compatible with modern SCADA systems? The 05701-A-0327 communicates over the Honeywell TDC 3000 proprietary LCN (Local Control Network) and UCN (Universal Control Network) bus. Integration with modern SCADA platforms such as Honeywell Experion PKS or third-party systems is achieved via OPC-DA/OPC-UA gateway modules or Honeywell's Control Data Access (CDA) server, which translate LCN/UCN data into standard industrial protocols. This ensures full SCADA/HMI compatibility without replacing the existing TDC 3000 infrastructure.

Q2: How does the 05701-A-0327 support remote diagnostics and predictive maintenance? Relay output states and switching events are continuously logged in the TDC 3000 History Module and accessible via the LCN data highway. By connecting an OPC-UA edge gateway to the TDC 3000 network, maintenance engineers can remotely query relay status, review event logs, and set up condition-based alerts — enabling predictive maintenance without requiring physical access to the control panel.

Q3: What is the network stability and communication latency of the TDC 3000 relay output system? The TDC 3000 LCN operates as a deterministic token-passing network with a defined scan cycle, ensuring consistent and predictable communication latency for relay output commands. This deterministic behavior is critical for interlock and safety applications where relay switching must occur within defined time windows. The network architecture supports redundant LCN configurations for high-availability installations.

Q4: Does the Honeywell 05701-A-0327 come with a warranty, and what pre-shipment testing is performed? Yes. Every Honeywell 05701-A-0327 supplied by NANKMOS includes a 12-Month Warranty covering manufacturing defects and functional performance. Prior to shipment, each unit undergoes functional verification testing to confirm relay output switching, backplane communication integrity, and electrical isolation. In-stock units are available for immediate dispatch, with full traceability documentation provided upon request.

Quality & Delivery Assurance

Functional InspectionFunctional Inspection

100% tested on professional platforms to ensure stable performance.

Anti-static PackagingAnti-static Packaging

Modules are packed in anti-static bags to prevent electrostatic damage.

Secure Export PackingSecure Export Packing

Cushion protection and strong cartons ensure safe transportation.

Worldwide ShippingWorldwide Shipping

Global logistics network supports air, sea and express delivery.

Documentation CheckDocumentation Check

Part number, revision and compatibility verified before shipment.

After-sales SupportAfter-sales Support

Professional technical support to help resolve your issues.

Related Models Often Requested

View More Related Models