Yokogawa AAR145-S00 S1 RTD Input Module

Yokogawa AAR145-S00 S1 is a NANKMOS industrial automation product record. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.

Brand names are used for identification only.
Product Snapshot

Availability & Sourcing Details

Yokogawa AAR145-S00 S1 is a NANKMOS industrial automation product record. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.

Controller Module PLC System CENTUM VP Yokogawa
Application
Controller Processing & System Control
Condition Options
New / Used / Refurbished
Availability
Confirmed by Email
Warranty
12 Months
Packaging
Anti-static Bag / Secure Box
Shipping
DHL / FedEx / UPS / Air / Sea

Product Information

ManufacturerYokogawa
ApplicationController Processing & System Control
Part Number / ModelAAR145-S00 S1
Compatible SystemCENTUM VP
SeriesCENTUM VP
Condition OptionsTo Confirm
Module TypeController / CPU Module
Warranty12 Months
PackagingAnti-static Bag / Secure Box
Shipping MethodsDHL / FedEx / UPS / Air / Sea
AvailabilityTo Confirm
Lead TimeTo Confirm
DocumentationPart number and revision checked before quote
Product Details

AAR145-S00 S1 Product Description

The Yokogawa AAR145-S00/S1 is a 16-channel RTD (Resistance Temperature Detector) input module engineered for the Centum VP Distributed Control System (DCS) platform. Designed to serve as a precision data acquisition node within Vnet/IP-based industrial networks, this module bridges the gap between field-level temperature sensors and upper-layer control, SCADA, and data visualization systems. In smart factory environments where real-time process data is the backbone of operational efficiency, the AAR145-S00/S1 delivers reliable, high-resolution signal acquisition with seamless integration into Yokogawa's proprietary Vnet/IP communication architecture.

As industrial facilities transition toward fully connected automation ecosystems, the demand for modules that can simultaneously handle precise measurement and robust network communication has never been greater. The AAR145-S00/S1 answers this demand by combining multi-channel RTD input capability with native Vnet/IP protocol support, enabling continuous, low-latency data flow from temperature sensors on the plant floor directly into the Centum VP controller domain — and from there, into SCADA dashboards, historian databases, and remote monitoring platforms.

In a fully networked smart factory, the AAR145-S00/S1 operates as a critical data acquisition node at the field level. RTD sensors installed on reactors, heat exchangers, pipelines, and furnaces feed temperature signals into the module's 16 analog input channels. These signals are digitized, scaled, and transmitted over the Vnet/IP network to the Centum VP Field Control Station (FCS), where control logic — including PID loops, alarm management, and interlock sequences — is executed in real time.

Within the Centum VP architecture, the AAR145-S00/S1 works in close coordination with other I/O modules such as the AAI141-S (analog input for 4–20 mA signals), the AAI543-S (multi-channel analog input/output), and the ADV151-P (digital input module), all sharing the same Vnet/IP backplane communication. This modular I/O design allows engineers to build scalable, high-density I/O subsystems without sacrificing network determinism or data integrity.

Data collected by the AAR145-S00/S1 flows upward through the Centum VP HIS (Human Interface Station), where operators monitor live temperature trends, configure alarm thresholds, and acknowledge process deviations. The HIS connects to the plant-wide Ethernet network, enabling integration with Yokogawa's Exaquantum process data historian and third-party SCADA platforms via OPC-DA or OPC-UA gateways. For facilities running mixed-vendor environments, protocol conversion gateways — such as those supporting Modbus TCP, PROFIBUS DP, or EtherNet/IP — can be deployed alongside the Centum VP system to bridge data from legacy PLCs, Siemens S7-series controllers, or Allen-Bradley ControlLogix platforms into the unified data layer.

At the edge, industrial Ethernet switches with managed VLAN and QoS capabilities ensure that Vnet/IP traffic from the AAR145-S00/S1 and its peer modules is prioritized and isolated from general IT network traffic. Redundant ring topologies supported by the Vnet/IP infrastructure provide automatic failover, ensuring that a single cable or switch failure does not interrupt data flow from field sensors to the control room. This network resilience is essential in continuous process industries such as oil refining, chemical production, and power generation, where even brief data interruptions can trigger costly process upsets.

For remote diagnostics and predictive maintenance, the temperature data acquired by the AAR145-S00/S1 can be routed to edge computing gateways that apply machine learning algorithms to detect early signs of equipment degradation — such as abnormal temperature gradients in motor windings or heat exchanger fouling. These edge gateways communicate with cloud-based asset management platforms, enabling maintenance teams to schedule interventions before failures occur, reducing unplanned downtime and extending equipment service life.

Many industrial facilities operate with fragmented automation architectures — a mix of legacy analog instrumentation, standalone PLCs, and modern DCS platforms that do not natively share data. The result is data silos: temperature readings locked inside standalone controllers, inaccessible to SCADA systems, historians, or enterprise MES platforms. The AAR145-S00/S1, integrated within the Centum VP DCS, directly addresses this challenge by providing a standardized, network-native path for RTD data from the field to every layer of the automation hierarchy.

Protocol incompatibility is another common barrier. Sites that have deployed a mix of Modbus RTU devices, PROFIBUS DP field instruments, and Vnet/IP-based DCS I/O often struggle to achieve unified data visibility. By deploying the AAR145-S00/S1 as the primary temperature acquisition module within the Centum VP system, and pairing it with appropriate protocol gateways at the network boundary, engineers can consolidate temperature data from all sources into a single SCADA or historian platform — eliminating manual data collection, reducing transcription errors, and enabling plant-wide KPI dashboards.

Remote monitoring and alarm management are equally critical. Without reliable, real-time temperature data flowing from field modules like the AAR145-S00/S1 to the control room and remote operations center, operators cannot respond quickly to process deviations. The module's deterministic Vnet/IP communication ensures that alarm signals reach the HIS and SCADA within milliseconds, enabling rapid response and reducing the risk of safety incidents. Alarm history is automatically logged in the Centum VP system and can be exported to compliance reporting tools, supporting regulatory audit requirements in pharmaceutical, food processing, and energy industries.

System scalability is built into the Centum VP I/O architecture. As production capacity expands, additional AAR145-S00/S1 modules can be added to existing I/O nests without reconfiguring the network or interrupting ongoing operations. This plug-and-expand capability, combined with the module's hot-swap support in redundant configurations, makes it an ideal choice for facilities planning phased automation upgrades or capacity expansions.

Q1: What communication protocol does the AAR145-S00/S1 use, and is it compatible with third-party SCADA systems? The AAR145-S00/S1 communicates natively over Yokogawa's Vnet/IP protocol within the Centum VP DCS. For integration with third-party SCADA platforms, data is accessed through the Centum VP HIS or via OPC-DA/OPC-UA server interfaces, which are supported by the Centum VP software suite. This enables connectivity with SCADA platforms from vendors such as Wonderware, Ignition, and Siemens WinCC without requiring hardware-level protocol conversion at the module itself.

Q2: How does the module ensure network stability and data integrity in high-noise industrial environments? The AAR145-S00/S1 is designed for installation within Centum VP I/O nests, which provide electrical isolation and EMI shielding. The Vnet/IP network supports redundant ring topology, so if a network segment fails, traffic is automatically rerouted within milliseconds. The module's cyclic data exchange mechanism ensures that temperature values are refreshed at deterministic intervals, and any communication fault is immediately flagged in the Centum VP alarm system for operator action.

Q3: Can the AAR145-S00/S1 support remote diagnostics and predictive maintenance applications? Yes. Temperature data acquired by the AAR145-S00/S1 is available in real time through the Centum VP data highway and can be forwarded to edge gateways or cloud platforms for advanced analytics. Yokogawa's Exaquantum historian and OPC-UA interfaces enable integration with third-party predictive maintenance tools. Diagnostic information about the module itself — including channel status, input range errors, and communication health — is accessible through the Centum VP engineering environment for remote troubleshooting without requiring on-site access.

Q4: What warranty and pre-shipment testing does the AAR145-S00/S1 include? Every AAR145-S00/S1 unit supplied by NANKMOS is covered by a 12-Month Warranty against manufacturing defects and functional failures. Prior to shipment, each module undergoes functional verification testing to confirm channel accuracy, communication integrity, and hardware health. Units are shipped in anti-static packaging with full documentation. In-stock units are available for immediate dispatch, with lead times confirmed at the time of order. For urgent project requirements, expedited shipping options are available upon request.

Quality & Delivery Assurance

Functional InspectionFunctional Inspection

100% tested on professional platforms to ensure stable performance.

Anti-static PackagingAnti-static Packaging

Modules are packed in anti-static bags to prevent electrostatic damage.

Secure Export PackingSecure Export Packing

Cushion protection and strong cartons ensure safe transportation.

Worldwide ShippingWorldwide Shipping

Global logistics network supports air, sea and express delivery.

Documentation CheckDocumentation Check

Part number, revision and compatibility verified before shipment.

After-sales SupportAfter-sales Support

Professional technical support to help resolve your issues.

Related Models Often Requested

View More Related Models