Functional Inspection100% tested on professional platforms to ensure stable performance.
GE Fanuc / Emerson IC695ALG626-KF is a NANKMOS industrial automation product record Listed under PACSystems series and Business & Industrial > Automation, Control & Flow Devices > Programmable Logic Controllers. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.
Brand names are used for identification only.
GE Fanuc / Emerson IC695ALG626-KF is a NANKMOS industrial automation product record Listed under PACSystems series and Business & Industrial > Automation, Control & Flow Devices > Programmable Logic Controllers. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.
| Manufacturer | GE Fanuc / Emerson |
|---|---|
| Application | Controller Processing & System Control |
| Part Number / Model | IC695ALG626-KF |
| Compatible System | PACSystems |
| Series | PACSystems |
| Condition Options | To Confirm |
| Module Type | Controller / CPU Module |
| Warranty | 12 Months |
| Packaging | Anti-static Bag / Secure Box |
| Shipping Methods | DHL / FedEx / UPS / Air / Sea |
| Availability | To Confirm |
| Lead Time | To Confirm |
| Documentation | Part number and revision checked before quote |
The GE IC695ALG626-KF is a high-density 16-channel analog input module engineered for the PACSystems RX3i platform, delivering precision signal acquisition and seamless data integration across the full industrial data chain. Designed for demanding smart factory environments, this module bridges field-level instrumentation — including pressure transmitters, temperature sensors, flow meters, and process analyzers — with PLC controllers, SCADA systems, HMI panels, and edge computing gateways. Its role in the automation data chain extends from raw signal capture at the I/O rack through protocol-level transmission to enterprise-level data visualization and remote diagnostics.
In modern connected factory architectures, the IC695ALG626-KF serves as a critical data acquisition node. Analog signals from field devices are conditioned, digitized, and passed through the RX3i backplane to the CPU module — such as the IC695CPE330 or IC695CPE400 — where they are processed and forwarded via Ethernet or PROFINET to upstream SCADA platforms. This continuous data flow enables real-time process monitoring, alarm management, and predictive maintenance without manual intervention.
When integrated with communication modules such as the IC695ETM001 Ethernet interface or the IC695PBM300 PROFIBUS master, the IC695ALG626-KF participates in multi-protocol network architectures that connect field instruments to distributed control systems. Data collected by this module can be routed through industrial Ethernet switches, transmitted to remote I/O nodes, and aggregated at edge gateways for cloud-based analytics or MES integration. This end-to-end connectivity eliminates data silos and supports full production transparency.
For facilities running mixed-protocol environments, the IC695ALG626-KF pairs effectively with protocol conversion gateways that translate between PROFIBUS, Modbus TCP, EtherNet/IP, and OPC-UA. This ensures that legacy field devices and modern IIoT-enabled sensors can coexist within the same data infrastructure, feeding unified dashboards and historian databases. Remote diagnostic tools can then access live analog channel data, channel health status, and fault codes without requiring on-site personnel.
The module supports configurable input ranges, channel-level diagnostics, and over-range detection — features that are essential for alarm tracking and process safety in chemical, energy, and discrete manufacturing applications. When combined with the IC695PSD040 power supply and IC695CHS016 backplane chassis, the IC695ALG626-KF forms a robust, scalable I/O subsystem capable of supporting system expansion as production demands grow.
All units supplied by NANKMOS are sourced from verified inventory, undergo pre-shipment functional testing, and are covered by a 12-Month Warranty. Stock is available for immediate dispatch to support urgent project timelines and MRO requirements.
The IC695ALG626-KF anchors the analog signal layer of a connected factory data architecture. Field instruments — including Rosemount pressure transmitters, Endress+Hauser flow sensors, and thermocouple-based temperature probes — deliver 4–20 mA or ±10 V signals directly to the module's input terminals. These signals are digitized at the module level and transferred across the RX3i backplane to the IC695CPE330 CPU, which executes control logic and packages process data for network transmission.
The IC695ETM001 Ethernet module enables the RX3i rack to communicate over industrial Ethernet, forwarding real-time analog data to SCADA servers running CIMPLICITY or Ignition. Simultaneously, the IC695PBM300 PROFIBUS master module can poll remote I/O nodes and variable-frequency drives on the plant floor, consolidating distributed process data into a single controller context. This multi-bus architecture ensures that the IC695ALG626-KF's analog readings are synchronized with digital I/O states from IC694MDL940 discrete output modules and network status from managed industrial Ethernet switches.
At the edge layer, protocol conversion gateways translate RX3i SRTP data into OPC-UA or MQTT streams, enabling integration with cloud-based MES platforms and digital twin environments. HMI panels connected via EtherNet/IP display live analog trends, alarm histories, and channel diagnostics sourced directly from the IC695ALG626-KF. Remote engineers can access the same data through SCADA web clients, enabling off-site process monitoring and fault diagnosis without travel.
For system expansion, additional IC695ALG626-KF modules can be added to the RX3i chassis alongside IC695ALG704 analog output modules, IC695MDL664 discrete input modules, and IC695HSC304 high-speed counter modules, creating a comprehensive mixed I/O platform. The modular architecture of the PACSystems RX3i ensures that data capacity scales linearly with production requirements, supporting phased smart factory rollouts.
Many industrial facilities face persistent challenges with protocol fragmentation, data silos, and limited remote visibility. The IC695ALG626-KF directly addresses these issues within the PACSystems RX3i framework. When field devices use legacy analog signaling while upstream systems demand digital network data, this module provides the conversion bridge — transforming physical process variables into structured digital values that SCADA, historian, and MES systems can consume natively.
Channel-level diagnostics enable proactive alarm tracking: open-wire faults, over-range conditions, and signal drift are detected at the module level and surfaced through the RX3i fault table, SCADA alarm displays, and remote diagnostic clients. This eliminates the need for manual channel inspection and reduces mean time to repair (MTTR) for instrumentation faults.
For production line transparency, the IC695ALG626-KF supports continuous data logging to historian databases, enabling trend analysis, shift reporting, and OEE calculations. When integrated with edge gateways and cloud analytics platforms, the module's data contributes to predictive maintenance models that identify equipment degradation before failures occur. System expansion is straightforward: additional modules slot into existing RX3i backplanes without rewiring, and configuration changes are applied through Proficy Machine Edition without production interruption.
Q: What communication protocols does the IC695ALG626-KF support for SCADA integration? A: The IC695ALG626-KF transmits analog data over the RX3i backplane to the CPU, which communicates via SRTP natively. With the IC695ETM001 Ethernet module, data is accessible via Modbus TCP and EtherNet/IP. OPC-UA and MQTT connectivity is achievable through protocol conversion gateways, enabling integration with Ignition, WinCC, and cloud-based SCADA platforms.
Q: How does the module handle network latency and real-time data requirements? A: The IC695ALG626-KF performs analog-to-digital conversion at the module level with scan rates configurable through Proficy Machine Edition. Backplane data transfer to the CPU occurs within the controller scan cycle, typically 1–10 ms, ensuring that SCADA and HMI systems receive updated process values with minimal latency. For time-critical applications, scan rate optimization and dedicated Ethernet segments are recommended.
Q: Can the IC695ALG626-KF be integrated into mixed-protocol factory networks alongside PROFIBUS and Modbus devices? A: Yes. The PACSystems RX3i platform supports simultaneous operation of multiple communication modules. The IC695ALG626-KF coexists with IC695PBM300 PROFIBUS masters, IC695ETM001 Ethernet interfaces, and serial communication modules, allowing analog data from this module to be correlated with data from PROFIBUS drives, Modbus sensors, and EtherNet/IP devices within a unified control context.
Q: What warranty and pre-shipment testing does NANKMOS provide for the IC695ALG626-KF? A: Every IC695ALG626-KF unit supplied by NANKMOS undergoes pre-shipment functional verification to confirm channel integrity, backplane communication, and diagnostic response. All units are covered by a 12-Month Warranty from the date of shipment. NANKMOS maintains verified inventory with documented sourcing to support traceability requirements for critical automation projects.
Functional Inspection100% tested on professional platforms to ensure stable performance.
Anti-static PackagingModules are packed in anti-static bags to prevent electrostatic damage.
Secure Export PackingCushion protection and strong cartons ensure safe transportation.
Worldwide ShippingGlobal logistics network supports air, sea and express delivery.
Documentation CheckPart number, revision and compatibility verified before shipment.