Global Industrial Automation Sourcing

EN  /  CN
NANKMOSEmpower Industry. Advance Future.
Send Inquiry

GE Fanuc / Emerson IC695RMX128 PLC Redundancy Module

GE Fanuc / Emerson IC695RMX128 is a NANKMOS industrial automation product record Listed under Fanuc series and Business & Industrial > Automation, Control & Flow Devices > Programmable Logic Controllers. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.

Brand names are used for identification only.
Product Snapshot

Availability & Sourcing Details

GE Fanuc / Emerson IC695RMX128 is a NANKMOS industrial automation product record Listed under Fanuc series and Business & Industrial > Automation, Control & Flow Devices > Programmable Logic Controllers. Confirm condition, availability, lead time, compatibility and documentation by email inquiry.

Controller Module PLC System Fanuc GE Fanuc / Emerson
Application
Controller Processing & System Control
Condition Options
New / Used / Refurbished
Availability
Confirmed by Email
Warranty
12 Months
Packaging
Anti-static Bag / Secure Box
Shipping
DHL / FedEx / UPS / Air / Sea

Product Information

ManufacturerGE Fanuc / Emerson
ApplicationController Processing & System Control
Part Number / ModelIC695RMX128
Compatible SystemFanuc
SeriesFanuc
Condition OptionsTo Confirm
Module TypeController / CPU Module
Warranty12 Months
PackagingAnti-static Bag / Secure Box
Shipping MethodsDHL / FedEx / UPS / Air / Sea
AvailabilityTo Confirm
Lead TimeTo Confirm
DocumentationPart number and revision checked before quote
Product Details

IC695RMX128 Product Description

The GE IC695RMX128 is a Redundancy Memory Exchange Module engineered for the PACSystems RX3i platform, delivering deterministic hot-standby failover and real-time memory synchronization across redundant CPU pairs. In smart factory environments where unplanned downtime translates directly to production loss, the IC695RMX128 forms the backbone of a resilient industrial data link — ensuring that control logic, I/O states, and process variables are continuously mirrored between primary and secondary controllers without interruption to field devices or upstream SCADA systems.

Designed for mission-critical automation sites in oil and gas, power generation, water treatment, and discrete manufacturing, this module integrates seamlessly into the PACSystems RX3i backplane alongside CPUs such as the IC695CPE330 and IC695CPE400, enabling sub-second switchover that is transparent to connected HMI panels, remote I/O racks, and Ethernet-based supervisory networks. Its role in the data chain extends from the field level — where sensors, actuators, and distributed I/O modules feed real-time signals — through the control layer, and up to enterprise MES and SCADA platforms.

In a fully connected smart factory architecture, the IC695RMX128 operates at the heart of the control layer, synchronizing process data between redundant PACSystems RX3i CPUs while the surrounding ecosystem handles signal acquisition, protocol translation, and supervisory communication. At the field level, distributed I/O modules such as the IC695ACC400 adapter and IC694MDL660 discrete input modules collect signals from proximity sensors, flow transmitters, and motor feedback devices, feeding live process values into the primary CPU's memory tables — values that the IC695RMX128 continuously mirrors to the standby CPU.

Upstream, the PACSystems RX3i communicates with plant-floor HMI terminals and SCADA servers via the IC695ETM001 Ethernet module, which supports SRTP and EGD protocols for high-speed data exchange with iFIX, Wonderware, or Ignition SCADA platforms. When the IC695RMX128 executes a failover event, the standby CPU assumes control with a fully synchronized memory image — meaning SCADA trend displays, alarm histories, and operator dashboards experience no data gap or communication dropout.

For sites integrating legacy serial devices — such as Modbus RTU drives, HART field instruments, or RS-485 sensors — the IC695CMM002 serial communications module bridges these protocols into the RX3i backplane, ensuring that all field data is captured within the redundant control domain protected by the IC695RMX128. Variable frequency drives communicating over Profibus DP or EtherNet/IP are similarly integrated through the IC695PBM300 Profibus master module, with drive status, speed references, and fault codes all included in the synchronized memory block.

At the network infrastructure layer, managed industrial Ethernet switches provide the backbone for deterministic communication between the RX3i rack, remote I/O drops, and the control room. Fiber-optic uplinks ensure noise immunity across long cable runs in high-EMI environments such as motor control centers and switchgear rooms. Edge gateway devices aggregate data from multiple RX3i systems and forward normalized payloads to cloud-based analytics platforms or on-premise historians, enabling real-time OEE dashboards and predictive maintenance workflows that depend on the continuous, uninterrupted data stream that the IC695RMX128 guarantees.

Industrial automation sites frequently encounter data continuity challenges that undermine production transparency and remote monitoring capability. The IC695RMX128 directly addresses several of the most common failure modes:

Protocol Fragmentation: When legacy Modbus RTU devices, Profibus DP drives, and modern EtherNet/IP I/O coexist on the same production line, data silos emerge at the controller boundary. The PACSystems RX3i platform — with the IC695RMX128 ensuring controller continuity — acts as a unified data aggregation point, normalizing all field signals into a single, synchronized memory image accessible to SCADA and MES systems via standard Ethernet protocols.

Unplanned Downtime and Data Loss: A single CPU failure in a non-redundant system can result in hours of lost production and corrupted historian data. The IC695RMX128 eliminates this risk by maintaining a live mirror of the primary CPU state, enabling automatic switchover in under one second — preserving alarm logs, setpoint histories, and production counters without operator intervention.

Remote Monitoring Gaps: In geographically distributed facilities — substations, pipeline pump stations, water treatment plants — remote diagnostics depend on continuous controller availability. With the IC695RMX128 in place, remote SCADA operators maintain uninterrupted visibility into process variables, equipment health metrics, and alarm states even during controller maintenance windows.

Production Line Transparency and Alarm Traceability: Redundant control architectures supported by the IC695RMX128 ensure that alarm timestamps, event sequences, and production batch records are never interrupted by controller transitions, providing accurate audit trails for quality management systems and regulatory compliance reporting.

System Scalability: As production lines expand and new I/O points are added, the PACSystems RX3i platform scales through additional backplane slots and remote I/O racks without disrupting the redundancy architecture managed by the IC695RMX128, protecting the capital investment in the existing control infrastructure.

Q1: What is the typical switchover time for the IC695RMX128, and will it affect my SCADA communication?The IC695RMX128 achieves sub-second hot-standby switchover. Because the standby CPU maintains a fully synchronized memory image — including all I/O tables, data registers, and communication buffers — SCADA systems communicating via SRTP or EGD experience no data dropout or connection reset during the transition. HMI displays and historian trend records remain continuous.

Q2: Which communication protocols are compatible with the PACSystems RX3i redundancy system?The RX3i platform supports SRTP, EGD, Modbus TCP, EtherNet/IP, and Profinet via its Ethernet modules (e.g., IC695ETM001). The IC695RMX128 operates on a dedicated redundancy bus independent of these Ethernet protocols, ensuring that memory synchronization does not compete with SCADA or HMI traffic for network bandwidth.

Q3: Can the IC695RMX128 be integrated into an existing non-redundant RX3i system?Yes. The IC695RMX128 is designed for integration into existing PACSystems RX3i backplanes (IC695CHS016, IC695CHS012) alongside compatible CPUs such as the IC695CPE330 or IC695CPE400. Migration from simplex to redundant architecture requires a second CPU module and backplane, with the IC695RMX128 establishing the memory exchange link between the two controllers.

Q4: What does the 12-month warranty cover, and has the unit been tested before shipment?Every IC695RMX128 unit supplied by NANKMOS undergoes functional testing and inspection prior to shipment. The 12-month warranty covers hardware defects and operational failures under normal industrial operating conditions. In-stock units are available for immediate dispatch to support urgent project timelines and minimize procurement lead times.

Quality & Delivery Assurance

Functional InspectionFunctional Inspection

100% tested on professional platforms to ensure stable performance.

Anti-static PackagingAnti-static Packaging

Modules are packed in anti-static bags to prevent electrostatic damage.

Secure Export PackingSecure Export Packing

Cushion protection and strong cartons ensure safe transportation.

Worldwide ShippingWorldwide Shipping

Global logistics network supports air, sea and express delivery.

Documentation CheckDocumentation Check

Part number, revision and compatibility verified before shipment.

After-sales SupportAfter-sales Support

Professional technical support to help resolve your issues.

Related Models Often Requested

View More Related Models